Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure
Radon passive monitors based on solid state nuclear track detectors (SSNTD), especially CR-39, are widely used in radon and thoron studies. They may be subjected to the influence of external factors, like changing of temperature, humidity, and pressure, both before and during the measurement. Evalua...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8391802/ https://www.ncbi.nlm.nih.gov/pubmed/34444098 http://dx.doi.org/10.3390/ijerph18168346 |
_version_ | 1783743357622681600 |
---|---|
author | Janik, Miroslaw Hasan, Md. Mahamudul Bossew, Peter Kavasi, Norbert |
author_facet | Janik, Miroslaw Hasan, Md. Mahamudul Bossew, Peter Kavasi, Norbert |
author_sort | Janik, Miroslaw |
collection | PubMed |
description | Radon passive monitors based on solid state nuclear track detectors (SSNTD), especially CR-39, are widely used in radon and thoron studies. They may be subjected to the influence of external factors, like changing of temperature, humidity, and pressure, both before and during the measurement. Evaluation of the exposed detectors involves chemical processing, whose conditions also influence the measurement results. The aim of this study was to check several factors, as to whether they may modify the response of CR-39 detector: concerning the phase before evaluation, storage time, and temperature during storage; and concerning the evaluation procedure, etching time, and pre-etching treatment using hot water and carbon dioxide atmosphere. Two experiments were conducted by irradiation of CR-39 detectors using alpha particles emitted from a mono-energetic (241)Am source and exposed in radon atmosphere. Track density dependence of the age of production was found to be statistically not significant. On the other hand, pre-etching treatment using hot water and carbon dioxide with different etching times showed statistically significant effects on track area, track sensitivity, and roundness. It was concluded that there are simple methods to increase performance of nuclear track detectors, and that storage time is not a factor of concern. |
format | Online Article Text |
id | pubmed-8391802 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83918022021-08-28 Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure Janik, Miroslaw Hasan, Md. Mahamudul Bossew, Peter Kavasi, Norbert Int J Environ Res Public Health Article Radon passive monitors based on solid state nuclear track detectors (SSNTD), especially CR-39, are widely used in radon and thoron studies. They may be subjected to the influence of external factors, like changing of temperature, humidity, and pressure, both before and during the measurement. Evaluation of the exposed detectors involves chemical processing, whose conditions also influence the measurement results. The aim of this study was to check several factors, as to whether they may modify the response of CR-39 detector: concerning the phase before evaluation, storage time, and temperature during storage; and concerning the evaluation procedure, etching time, and pre-etching treatment using hot water and carbon dioxide atmosphere. Two experiments were conducted by irradiation of CR-39 detectors using alpha particles emitted from a mono-energetic (241)Am source and exposed in radon atmosphere. Track density dependence of the age of production was found to be statistically not significant. On the other hand, pre-etching treatment using hot water and carbon dioxide with different etching times showed statistically significant effects on track area, track sensitivity, and roundness. It was concluded that there are simple methods to increase performance of nuclear track detectors, and that storage time is not a factor of concern. MDPI 2021-08-06 /pmc/articles/PMC8391802/ /pubmed/34444098 http://dx.doi.org/10.3390/ijerph18168346 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Janik, Miroslaw Hasan, Md. Mahamudul Bossew, Peter Kavasi, Norbert Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure |
title | Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure |
title_full | Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure |
title_fullStr | Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure |
title_full_unstemmed | Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure |
title_short | Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure |
title_sort | effects of storage time and pre-etching treatment of cr-39 detectors on their response to alpha radiation exposure |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8391802/ https://www.ncbi.nlm.nih.gov/pubmed/34444098 http://dx.doi.org/10.3390/ijerph18168346 |
work_keys_str_mv | AT janikmiroslaw effectsofstoragetimeandpreetchingtreatmentofcr39detectorsontheirresponsetoalpharadiationexposure AT hasanmdmahamudul effectsofstoragetimeandpreetchingtreatmentofcr39detectorsontheirresponsetoalpharadiationexposure AT bossewpeter effectsofstoragetimeandpreetchingtreatmentofcr39detectorsontheirresponsetoalpharadiationexposure AT kavasinorbert effectsofstoragetimeandpreetchingtreatmentofcr39detectorsontheirresponsetoalpharadiationexposure |