Cargando…

Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure

Radon passive monitors based on solid state nuclear track detectors (SSNTD), especially CR-39, are widely used in radon and thoron studies. They may be subjected to the influence of external factors, like changing of temperature, humidity, and pressure, both before and during the measurement. Evalua...

Descripción completa

Detalles Bibliográficos
Autores principales: Janik, Miroslaw, Hasan, Md. Mahamudul, Bossew, Peter, Kavasi, Norbert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8391802/
https://www.ncbi.nlm.nih.gov/pubmed/34444098
http://dx.doi.org/10.3390/ijerph18168346
_version_ 1783743357622681600
author Janik, Miroslaw
Hasan, Md. Mahamudul
Bossew, Peter
Kavasi, Norbert
author_facet Janik, Miroslaw
Hasan, Md. Mahamudul
Bossew, Peter
Kavasi, Norbert
author_sort Janik, Miroslaw
collection PubMed
description Radon passive monitors based on solid state nuclear track detectors (SSNTD), especially CR-39, are widely used in radon and thoron studies. They may be subjected to the influence of external factors, like changing of temperature, humidity, and pressure, both before and during the measurement. Evaluation of the exposed detectors involves chemical processing, whose conditions also influence the measurement results. The aim of this study was to check several factors, as to whether they may modify the response of CR-39 detector: concerning the phase before evaluation, storage time, and temperature during storage; and concerning the evaluation procedure, etching time, and pre-etching treatment using hot water and carbon dioxide atmosphere. Two experiments were conducted by irradiation of CR-39 detectors using alpha particles emitted from a mono-energetic (241)Am source and exposed in radon atmosphere. Track density dependence of the age of production was found to be statistically not significant. On the other hand, pre-etching treatment using hot water and carbon dioxide with different etching times showed statistically significant effects on track area, track sensitivity, and roundness. It was concluded that there are simple methods to increase performance of nuclear track detectors, and that storage time is not a factor of concern.
format Online
Article
Text
id pubmed-8391802
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83918022021-08-28 Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure Janik, Miroslaw Hasan, Md. Mahamudul Bossew, Peter Kavasi, Norbert Int J Environ Res Public Health Article Radon passive monitors based on solid state nuclear track detectors (SSNTD), especially CR-39, are widely used in radon and thoron studies. They may be subjected to the influence of external factors, like changing of temperature, humidity, and pressure, both before and during the measurement. Evaluation of the exposed detectors involves chemical processing, whose conditions also influence the measurement results. The aim of this study was to check several factors, as to whether they may modify the response of CR-39 detector: concerning the phase before evaluation, storage time, and temperature during storage; and concerning the evaluation procedure, etching time, and pre-etching treatment using hot water and carbon dioxide atmosphere. Two experiments were conducted by irradiation of CR-39 detectors using alpha particles emitted from a mono-energetic (241)Am source and exposed in radon atmosphere. Track density dependence of the age of production was found to be statistically not significant. On the other hand, pre-etching treatment using hot water and carbon dioxide with different etching times showed statistically significant effects on track area, track sensitivity, and roundness. It was concluded that there are simple methods to increase performance of nuclear track detectors, and that storage time is not a factor of concern. MDPI 2021-08-06 /pmc/articles/PMC8391802/ /pubmed/34444098 http://dx.doi.org/10.3390/ijerph18168346 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Janik, Miroslaw
Hasan, Md. Mahamudul
Bossew, Peter
Kavasi, Norbert
Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure
title Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure
title_full Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure
title_fullStr Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure
title_full_unstemmed Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure
title_short Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure
title_sort effects of storage time and pre-etching treatment of cr-39 detectors on their response to alpha radiation exposure
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8391802/
https://www.ncbi.nlm.nih.gov/pubmed/34444098
http://dx.doi.org/10.3390/ijerph18168346
work_keys_str_mv AT janikmiroslaw effectsofstoragetimeandpreetchingtreatmentofcr39detectorsontheirresponsetoalpharadiationexposure
AT hasanmdmahamudul effectsofstoragetimeandpreetchingtreatmentofcr39detectorsontheirresponsetoalpharadiationexposure
AT bossewpeter effectsofstoragetimeandpreetchingtreatmentofcr39detectorsontheirresponsetoalpharadiationexposure
AT kavasinorbert effectsofstoragetimeandpreetchingtreatmentofcr39detectorsontheirresponsetoalpharadiationexposure