Cargando…

On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode

We report the microfabrication and characterization of gold microband electrodes on silicon using standard microfabrication methods, i.e., lithography and etching techniques. A two-step electrodeposition process was carried out using the on-chip platinum reference and gold counter electrodes, thus i...

Descripción completa

Detalles Bibliográficos
Autores principales: Madden, Julia, Barrett, Colm, Laffir, Fathima R., Thompson, Michael, Galvin, Paul, O’ Riordan, Alan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8392376/
https://www.ncbi.nlm.nih.gov/pubmed/34436051
http://dx.doi.org/10.3390/bios11080249
_version_ 1783743488472383488
author Madden, Julia
Barrett, Colm
Laffir, Fathima R.
Thompson, Michael
Galvin, Paul
O’ Riordan, Alan
author_facet Madden, Julia
Barrett, Colm
Laffir, Fathima R.
Thompson, Michael
Galvin, Paul
O’ Riordan, Alan
author_sort Madden, Julia
collection PubMed
description We report the microfabrication and characterization of gold microband electrodes on silicon using standard microfabrication methods, i.e., lithography and etching techniques. A two-step electrodeposition process was carried out using the on-chip platinum reference and gold counter electrodes, thus incorporating glucose oxidase onto a platinum-modified, gold microband electrode with an o-phenylenediamine and ß-cyclodextrin mixture. The as-fabricated electrodes were studied using optical microscopy, scanning electron microscopy, and atomic force microscopy. The two-step electrodeposition process was conducted in low sample volumes (50 µL) of both solutions required for biosensor construction. Cyclic voltammetry and electrochemical impedance spectroscopy were utilised for electrochemical characterization at each stage of the deposition process. The enzymatic-based microband biosensor demonstrated a linear response to glucose from 2.5–15 mM, using both linear sweep voltammetry and chronoamperometric measurements in buffer-based solutions. The biosensor performance was examined in 30 µL volumes of fetal bovine serum. Whilst a reduction in the sensor sensitivity was evident within 100% serum samples (compared to buffer media), the sensor demonstrated linear glucose detection with increasing glucose concentrations (5–17 mM).
format Online
Article
Text
id pubmed-8392376
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83923762021-08-28 On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode Madden, Julia Barrett, Colm Laffir, Fathima R. Thompson, Michael Galvin, Paul O’ Riordan, Alan Biosensors (Basel) Article We report the microfabrication and characterization of gold microband electrodes on silicon using standard microfabrication methods, i.e., lithography and etching techniques. A two-step electrodeposition process was carried out using the on-chip platinum reference and gold counter electrodes, thus incorporating glucose oxidase onto a platinum-modified, gold microband electrode with an o-phenylenediamine and ß-cyclodextrin mixture. The as-fabricated electrodes were studied using optical microscopy, scanning electron microscopy, and atomic force microscopy. The two-step electrodeposition process was conducted in low sample volumes (50 µL) of both solutions required for biosensor construction. Cyclic voltammetry and electrochemical impedance spectroscopy were utilised for electrochemical characterization at each stage of the deposition process. The enzymatic-based microband biosensor demonstrated a linear response to glucose from 2.5–15 mM, using both linear sweep voltammetry and chronoamperometric measurements in buffer-based solutions. The biosensor performance was examined in 30 µL volumes of fetal bovine serum. Whilst a reduction in the sensor sensitivity was evident within 100% serum samples (compared to buffer media), the sensor demonstrated linear glucose detection with increasing glucose concentrations (5–17 mM). MDPI 2021-07-25 /pmc/articles/PMC8392376/ /pubmed/34436051 http://dx.doi.org/10.3390/bios11080249 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Madden, Julia
Barrett, Colm
Laffir, Fathima R.
Thompson, Michael
Galvin, Paul
O’ Riordan, Alan
On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode
title On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode
title_full On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode
title_fullStr On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode
title_full_unstemmed On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode
title_short On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode
title_sort on-chip glucose detection based on glucose oxidase immobilized on a platinum-modified, gold microband electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8392376/
https://www.ncbi.nlm.nih.gov/pubmed/34436051
http://dx.doi.org/10.3390/bios11080249
work_keys_str_mv AT maddenjulia onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode
AT barrettcolm onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode
AT laffirfathimar onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode
AT thompsonmichael onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode
AT galvinpaul onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode
AT oriordanalan onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode