Cargando…
On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode
We report the microfabrication and characterization of gold microband electrodes on silicon using standard microfabrication methods, i.e., lithography and etching techniques. A two-step electrodeposition process was carried out using the on-chip platinum reference and gold counter electrodes, thus i...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8392376/ https://www.ncbi.nlm.nih.gov/pubmed/34436051 http://dx.doi.org/10.3390/bios11080249 |
_version_ | 1783743488472383488 |
---|---|
author | Madden, Julia Barrett, Colm Laffir, Fathima R. Thompson, Michael Galvin, Paul O’ Riordan, Alan |
author_facet | Madden, Julia Barrett, Colm Laffir, Fathima R. Thompson, Michael Galvin, Paul O’ Riordan, Alan |
author_sort | Madden, Julia |
collection | PubMed |
description | We report the microfabrication and characterization of gold microband electrodes on silicon using standard microfabrication methods, i.e., lithography and etching techniques. A two-step electrodeposition process was carried out using the on-chip platinum reference and gold counter electrodes, thus incorporating glucose oxidase onto a platinum-modified, gold microband electrode with an o-phenylenediamine and ß-cyclodextrin mixture. The as-fabricated electrodes were studied using optical microscopy, scanning electron microscopy, and atomic force microscopy. The two-step electrodeposition process was conducted in low sample volumes (50 µL) of both solutions required for biosensor construction. Cyclic voltammetry and electrochemical impedance spectroscopy were utilised for electrochemical characterization at each stage of the deposition process. The enzymatic-based microband biosensor demonstrated a linear response to glucose from 2.5–15 mM, using both linear sweep voltammetry and chronoamperometric measurements in buffer-based solutions. The biosensor performance was examined in 30 µL volumes of fetal bovine serum. Whilst a reduction in the sensor sensitivity was evident within 100% serum samples (compared to buffer media), the sensor demonstrated linear glucose detection with increasing glucose concentrations (5–17 mM). |
format | Online Article Text |
id | pubmed-8392376 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83923762021-08-28 On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode Madden, Julia Barrett, Colm Laffir, Fathima R. Thompson, Michael Galvin, Paul O’ Riordan, Alan Biosensors (Basel) Article We report the microfabrication and characterization of gold microband electrodes on silicon using standard microfabrication methods, i.e., lithography and etching techniques. A two-step electrodeposition process was carried out using the on-chip platinum reference and gold counter electrodes, thus incorporating glucose oxidase onto a platinum-modified, gold microband electrode with an o-phenylenediamine and ß-cyclodextrin mixture. The as-fabricated electrodes were studied using optical microscopy, scanning electron microscopy, and atomic force microscopy. The two-step electrodeposition process was conducted in low sample volumes (50 µL) of both solutions required for biosensor construction. Cyclic voltammetry and electrochemical impedance spectroscopy were utilised for electrochemical characterization at each stage of the deposition process. The enzymatic-based microband biosensor demonstrated a linear response to glucose from 2.5–15 mM, using both linear sweep voltammetry and chronoamperometric measurements in buffer-based solutions. The biosensor performance was examined in 30 µL volumes of fetal bovine serum. Whilst a reduction in the sensor sensitivity was evident within 100% serum samples (compared to buffer media), the sensor demonstrated linear glucose detection with increasing glucose concentrations (5–17 mM). MDPI 2021-07-25 /pmc/articles/PMC8392376/ /pubmed/34436051 http://dx.doi.org/10.3390/bios11080249 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Madden, Julia Barrett, Colm Laffir, Fathima R. Thompson, Michael Galvin, Paul O’ Riordan, Alan On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode |
title | On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode |
title_full | On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode |
title_fullStr | On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode |
title_full_unstemmed | On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode |
title_short | On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode |
title_sort | on-chip glucose detection based on glucose oxidase immobilized on a platinum-modified, gold microband electrode |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8392376/ https://www.ncbi.nlm.nih.gov/pubmed/34436051 http://dx.doi.org/10.3390/bios11080249 |
work_keys_str_mv | AT maddenjulia onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode AT barrettcolm onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode AT laffirfathimar onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode AT thompsonmichael onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode AT galvinpaul onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode AT oriordanalan onchipglucosedetectionbasedonglucoseoxidaseimmobilizedonaplatinummodifiedgoldmicrobandelectrode |