Cargando…

Plate Fixation for Irreducible Proximal Humeral Fractures in Children and Adolescents—A Single-Center Case Series of Six Patients

Background: Recommended treatment for severely displaced proximal humeral fractures in children is the closed reduction and percutaneous fixation by K-wires or intramedullary nailing. Methods: From January 2016 to January 2017 6, 21 children/adolescents (range 8 to 16 years) with proximal humeral fr...

Descripción completa

Detalles Bibliográficos
Autores principales: Freislederer, Florian, Bensler, Susanne, Specht, Thomas, Magerkurth, Olaf, Eid, Karim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8393487/
https://www.ncbi.nlm.nih.gov/pubmed/34438526
http://dx.doi.org/10.3390/children8080635
_version_ 1783743737571049472
author Freislederer, Florian
Bensler, Susanne
Specht, Thomas
Magerkurth, Olaf
Eid, Karim
author_facet Freislederer, Florian
Bensler, Susanne
Specht, Thomas
Magerkurth, Olaf
Eid, Karim
author_sort Freislederer, Florian
collection PubMed
description Background: Recommended treatment for severely displaced proximal humeral fractures in children is the closed reduction and percutaneous fixation by K-wires or intramedullary nailing. Methods: From January 2016 to January 2017 6, 21 children/adolescents (range 8 to 16 years) with proximal humeral fractures were treated surgically for severe displacement. In these six patients, several attempts of closed reduction were unsuccessful, and an open reduction was performed. The humeral head was fixed with a 3.5 mm T-plate without affecting the growth plate. Plate removal was performed at a mean interval of 132 days after initial surgery. Two years after initial surgery, the clinical outcome was assessed by the Constant–Murley score and QuickDASH score (including sport/music and work) and the shoulder joint was evaluated with a standardized sonographic examination for the rotator cuff and the conjoint tendon. Results: In all six patients, dorsal displacement of the fracture was irreducible due to the interposition of tendinous or osseous structures. Intraoperatively, the interposed structures were the long biceps tendon in two, periosteal tissue in two, a bony fragment in one, and the long biceps tendon together with the conjoint tendon in one case. At mean follow-up of 26 months (range 22 months to 29 months), patients showed very good clinical results with an excellent mean Constant–Murley score of 97.5 (range 91 to 100) and mean QuickDASH score (including sport/music and work) of 5.5 (range 0–20.8). An X-ray follow-up 6 weeks after surgery demonstrated early consolidation and correct alignment in all patients. A sonographic evaluation at 2 years post injury showed that the biceps and the conjoined tendon were intact in all patients. Conclusions: If a proximal humeral fracture is not reducible by closed means, a tissue entrapment (most likely biceps tendon) should be considered. Treatment with an open reduction and plate fixation yields very good clinical and radiological results and preserves interposed structures as the biceps and conjoint tendon.
format Online
Article
Text
id pubmed-8393487
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83934872021-08-28 Plate Fixation for Irreducible Proximal Humeral Fractures in Children and Adolescents—A Single-Center Case Series of Six Patients Freislederer, Florian Bensler, Susanne Specht, Thomas Magerkurth, Olaf Eid, Karim Children (Basel) Article Background: Recommended treatment for severely displaced proximal humeral fractures in children is the closed reduction and percutaneous fixation by K-wires or intramedullary nailing. Methods: From January 2016 to January 2017 6, 21 children/adolescents (range 8 to 16 years) with proximal humeral fractures were treated surgically for severe displacement. In these six patients, several attempts of closed reduction were unsuccessful, and an open reduction was performed. The humeral head was fixed with a 3.5 mm T-plate without affecting the growth plate. Plate removal was performed at a mean interval of 132 days after initial surgery. Two years after initial surgery, the clinical outcome was assessed by the Constant–Murley score and QuickDASH score (including sport/music and work) and the shoulder joint was evaluated with a standardized sonographic examination for the rotator cuff and the conjoint tendon. Results: In all six patients, dorsal displacement of the fracture was irreducible due to the interposition of tendinous or osseous structures. Intraoperatively, the interposed structures were the long biceps tendon in two, periosteal tissue in two, a bony fragment in one, and the long biceps tendon together with the conjoint tendon in one case. At mean follow-up of 26 months (range 22 months to 29 months), patients showed very good clinical results with an excellent mean Constant–Murley score of 97.5 (range 91 to 100) and mean QuickDASH score (including sport/music and work) of 5.5 (range 0–20.8). An X-ray follow-up 6 weeks after surgery demonstrated early consolidation and correct alignment in all patients. A sonographic evaluation at 2 years post injury showed that the biceps and the conjoined tendon were intact in all patients. Conclusions: If a proximal humeral fracture is not reducible by closed means, a tissue entrapment (most likely biceps tendon) should be considered. Treatment with an open reduction and plate fixation yields very good clinical and radiological results and preserves interposed structures as the biceps and conjoint tendon. MDPI 2021-07-26 /pmc/articles/PMC8393487/ /pubmed/34438526 http://dx.doi.org/10.3390/children8080635 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Freislederer, Florian
Bensler, Susanne
Specht, Thomas
Magerkurth, Olaf
Eid, Karim
Plate Fixation for Irreducible Proximal Humeral Fractures in Children and Adolescents—A Single-Center Case Series of Six Patients
title Plate Fixation for Irreducible Proximal Humeral Fractures in Children and Adolescents—A Single-Center Case Series of Six Patients
title_full Plate Fixation for Irreducible Proximal Humeral Fractures in Children and Adolescents—A Single-Center Case Series of Six Patients
title_fullStr Plate Fixation for Irreducible Proximal Humeral Fractures in Children and Adolescents—A Single-Center Case Series of Six Patients
title_full_unstemmed Plate Fixation for Irreducible Proximal Humeral Fractures in Children and Adolescents—A Single-Center Case Series of Six Patients
title_short Plate Fixation for Irreducible Proximal Humeral Fractures in Children and Adolescents—A Single-Center Case Series of Six Patients
title_sort plate fixation for irreducible proximal humeral fractures in children and adolescents—a single-center case series of six patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8393487/
https://www.ncbi.nlm.nih.gov/pubmed/34438526
http://dx.doi.org/10.3390/children8080635
work_keys_str_mv AT freisledererflorian platefixationforirreducibleproximalhumeralfracturesinchildrenandadolescentsasinglecentercaseseriesofsixpatients
AT benslersusanne platefixationforirreducibleproximalhumeralfracturesinchildrenandadolescentsasinglecentercaseseriesofsixpatients
AT spechtthomas platefixationforirreducibleproximalhumeralfracturesinchildrenandadolescentsasinglecentercaseseriesofsixpatients
AT magerkurtholaf platefixationforirreducibleproximalhumeralfracturesinchildrenandadolescentsasinglecentercaseseriesofsixpatients
AT eidkarim platefixationforirreducibleproximalhumeralfracturesinchildrenandadolescentsasinglecentercaseseriesofsixpatients