Cargando…
Difference in Computed Tomography Image Quality between Central Vein and Peripheral Vein Enhancement in Treatment Naive Esophageal Cancer Patients
SIMPLE SUMMARY: A chest CT via central vein enhancement not only eliminates peripheral vein regurgitation but also provides better image quality that facilitates precise clinical staging. A chest CT via central vein enhancement may be considered after tissue proof in order to better discriminate dis...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8394425/ https://www.ncbi.nlm.nih.gov/pubmed/34439325 http://dx.doi.org/10.3390/cancers13164172 |
_version_ | 1783743945218457600 |
---|---|
author | Chang, Chun-Bi Chen, Chien-Cheng Chen, Huan-Wu Wu, Ching-Feng Fu, Jui-Ying Hsieh, Ming-Ju Peng, Yang-Teng Lu, Ssu-Ying Wu, Ching-Yang |
author_facet | Chang, Chun-Bi Chen, Chien-Cheng Chen, Huan-Wu Wu, Ching-Feng Fu, Jui-Ying Hsieh, Ming-Ju Peng, Yang-Teng Lu, Ssu-Ying Wu, Ching-Yang |
author_sort | Chang, Chun-Bi |
collection | PubMed |
description | SIMPLE SUMMARY: A chest CT via central vein enhancement not only eliminates peripheral vein regurgitation but also provides better image quality that facilitates precise clinical staging. A chest CT via central vein enhancement may be considered after tissue proof in order to better discriminate disease severity. ABSTRACT: The differences in chest computed tomography (CT) image quality may affect the tumor stage. The aim of this study was to compare the image quality and accuracy of chest CT via central vein and peripheral vein enhancement. Fifty consecutive patients were enrolled from a tertiary medical center in Taiwan from May 2016 to March 2019. All the patients received a chest CT via central vein enhancement prior to neoadjuvant concurrent chemoradiation in order to compare the chest CT that was obtained via the peripheral vein. In addition, blind independent central reviews of chest CT via central vein and peripheral vein enhancement were conducted. For T and N stage, chest CT via central vein enhancement had a greater consistency with endoscopic ultrasonography and positron-emission tomography-computed tomography findings (kappa coefficients 0.4471 and 0.5564, respectively). In addition, chest CT via central vein enhancement also showed excellent agreement in the blind independent central review (kappa coefficient 0.9157). The changes in the T and N stage resulted in stage migration in 16 patients. Chest CT via central vein enhancement eliminated peripheral vein regurgitation and also provided more precise clinical staging. This study is registered under the registered NCT number 02887261. |
format | Online Article Text |
id | pubmed-8394425 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83944252021-08-28 Difference in Computed Tomography Image Quality between Central Vein and Peripheral Vein Enhancement in Treatment Naive Esophageal Cancer Patients Chang, Chun-Bi Chen, Chien-Cheng Chen, Huan-Wu Wu, Ching-Feng Fu, Jui-Ying Hsieh, Ming-Ju Peng, Yang-Teng Lu, Ssu-Ying Wu, Ching-Yang Cancers (Basel) Article SIMPLE SUMMARY: A chest CT via central vein enhancement not only eliminates peripheral vein regurgitation but also provides better image quality that facilitates precise clinical staging. A chest CT via central vein enhancement may be considered after tissue proof in order to better discriminate disease severity. ABSTRACT: The differences in chest computed tomography (CT) image quality may affect the tumor stage. The aim of this study was to compare the image quality and accuracy of chest CT via central vein and peripheral vein enhancement. Fifty consecutive patients were enrolled from a tertiary medical center in Taiwan from May 2016 to March 2019. All the patients received a chest CT via central vein enhancement prior to neoadjuvant concurrent chemoradiation in order to compare the chest CT that was obtained via the peripheral vein. In addition, blind independent central reviews of chest CT via central vein and peripheral vein enhancement were conducted. For T and N stage, chest CT via central vein enhancement had a greater consistency with endoscopic ultrasonography and positron-emission tomography-computed tomography findings (kappa coefficients 0.4471 and 0.5564, respectively). In addition, chest CT via central vein enhancement also showed excellent agreement in the blind independent central review (kappa coefficient 0.9157). The changes in the T and N stage resulted in stage migration in 16 patients. Chest CT via central vein enhancement eliminated peripheral vein regurgitation and also provided more precise clinical staging. This study is registered under the registered NCT number 02887261. MDPI 2021-08-19 /pmc/articles/PMC8394425/ /pubmed/34439325 http://dx.doi.org/10.3390/cancers13164172 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chang, Chun-Bi Chen, Chien-Cheng Chen, Huan-Wu Wu, Ching-Feng Fu, Jui-Ying Hsieh, Ming-Ju Peng, Yang-Teng Lu, Ssu-Ying Wu, Ching-Yang Difference in Computed Tomography Image Quality between Central Vein and Peripheral Vein Enhancement in Treatment Naive Esophageal Cancer Patients |
title | Difference in Computed Tomography Image Quality between Central Vein and Peripheral Vein Enhancement in Treatment Naive Esophageal Cancer Patients |
title_full | Difference in Computed Tomography Image Quality between Central Vein and Peripheral Vein Enhancement in Treatment Naive Esophageal Cancer Patients |
title_fullStr | Difference in Computed Tomography Image Quality between Central Vein and Peripheral Vein Enhancement in Treatment Naive Esophageal Cancer Patients |
title_full_unstemmed | Difference in Computed Tomography Image Quality between Central Vein and Peripheral Vein Enhancement in Treatment Naive Esophageal Cancer Patients |
title_short | Difference in Computed Tomography Image Quality between Central Vein and Peripheral Vein Enhancement in Treatment Naive Esophageal Cancer Patients |
title_sort | difference in computed tomography image quality between central vein and peripheral vein enhancement in treatment naive esophageal cancer patients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8394425/ https://www.ncbi.nlm.nih.gov/pubmed/34439325 http://dx.doi.org/10.3390/cancers13164172 |
work_keys_str_mv | AT changchunbi differenceincomputedtomographyimagequalitybetweencentralveinandperipheralveinenhancementintreatmentnaiveesophagealcancerpatients AT chenchiencheng differenceincomputedtomographyimagequalitybetweencentralveinandperipheralveinenhancementintreatmentnaiveesophagealcancerpatients AT chenhuanwu differenceincomputedtomographyimagequalitybetweencentralveinandperipheralveinenhancementintreatmentnaiveesophagealcancerpatients AT wuchingfeng differenceincomputedtomographyimagequalitybetweencentralveinandperipheralveinenhancementintreatmentnaiveesophagealcancerpatients AT fujuiying differenceincomputedtomographyimagequalitybetweencentralveinandperipheralveinenhancementintreatmentnaiveesophagealcancerpatients AT hsiehmingju differenceincomputedtomographyimagequalitybetweencentralveinandperipheralveinenhancementintreatmentnaiveesophagealcancerpatients AT pengyangteng differenceincomputedtomographyimagequalitybetweencentralveinandperipheralveinenhancementintreatmentnaiveesophagealcancerpatients AT lussuying differenceincomputedtomographyimagequalitybetweencentralveinandperipheralveinenhancementintreatmentnaiveesophagealcancerpatients AT wuchingyang differenceincomputedtomographyimagequalitybetweencentralveinandperipheralveinenhancementintreatmentnaiveesophagealcancerpatients |