Cargando…

Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination

The development of methods and miniaturized systems for fast and reliable quantitative determinations at the Point-of-Care is a top challenge and priority in diagnostics. In this work, a compact bench-top system, based on White Light Reflectance Spectroscopy, is introduced and evaluated in an applic...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsounidi, Dimitra, Koukouvinos, Georgios, Christianidis, Vasilios, Legaki, Evangelia, Giogli, Vasiliki, Panagiotopoulou, Konstantina, Taka, Styliani, Ekaterinidi, Zoi, Kakabakos, Sotirios, Raptis, Ioannis, Petrou, Panagiota
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8394791/
https://www.ncbi.nlm.nih.gov/pubmed/34436070
http://dx.doi.org/10.3390/bios11080268
_version_ 1783744028108390400
author Tsounidi, Dimitra
Koukouvinos, Georgios
Christianidis, Vasilios
Legaki, Evangelia
Giogli, Vasiliki
Panagiotopoulou, Konstantina
Taka, Styliani
Ekaterinidi, Zoi
Kakabakos, Sotirios
Raptis, Ioannis
Petrou, Panagiota
author_facet Tsounidi, Dimitra
Koukouvinos, Georgios
Christianidis, Vasilios
Legaki, Evangelia
Giogli, Vasiliki
Panagiotopoulou, Konstantina
Taka, Styliani
Ekaterinidi, Zoi
Kakabakos, Sotirios
Raptis, Ioannis
Petrou, Panagiota
author_sort Tsounidi, Dimitra
collection PubMed
description The development of methods and miniaturized systems for fast and reliable quantitative determinations at the Point-of-Care is a top challenge and priority in diagnostics. In this work, a compact bench-top system, based on White Light Reflectance Spectroscopy, is introduced and evaluated in an application with high clinical interest, namely the determination of C-Reactive protein (CRP) in human blood samples. The system encompassed all the necessary electronic and optical components for the performance of the assay, while the dedicated software provided the sequence and duration of assay steps, the reagents flow rate, the real-time monitoring of sensor response, and data processing to deliver in short time and accurately the CPR concentration in the sample. The CRP assay included two steps, the first comprising the binding of sample CRP onto the chip immobilized capture antibody and the second the reaction of the surface immunosorbed CRP molecules with the detection antibody. The assay duration was 12 min and the dynamic range was from 0.05 to 200 μg/mL, covering both normal values and acute inflammation incidents. There was an excellent agreement between CRP values determined in human plasma samples using the developed device with those received for the same samples by a standard diagnostic laboratory method.
format Online
Article
Text
id pubmed-8394791
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83947912021-08-28 Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination Tsounidi, Dimitra Koukouvinos, Georgios Christianidis, Vasilios Legaki, Evangelia Giogli, Vasiliki Panagiotopoulou, Konstantina Taka, Styliani Ekaterinidi, Zoi Kakabakos, Sotirios Raptis, Ioannis Petrou, Panagiota Biosensors (Basel) Article The development of methods and miniaturized systems for fast and reliable quantitative determinations at the Point-of-Care is a top challenge and priority in diagnostics. In this work, a compact bench-top system, based on White Light Reflectance Spectroscopy, is introduced and evaluated in an application with high clinical interest, namely the determination of C-Reactive protein (CRP) in human blood samples. The system encompassed all the necessary electronic and optical components for the performance of the assay, while the dedicated software provided the sequence and duration of assay steps, the reagents flow rate, the real-time monitoring of sensor response, and data processing to deliver in short time and accurately the CPR concentration in the sample. The CRP assay included two steps, the first comprising the binding of sample CRP onto the chip immobilized capture antibody and the second the reaction of the surface immunosorbed CRP molecules with the detection antibody. The assay duration was 12 min and the dynamic range was from 0.05 to 200 μg/mL, covering both normal values and acute inflammation incidents. There was an excellent agreement between CRP values determined in human plasma samples using the developed device with those received for the same samples by a standard diagnostic laboratory method. MDPI 2021-08-08 /pmc/articles/PMC8394791/ /pubmed/34436070 http://dx.doi.org/10.3390/bios11080268 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tsounidi, Dimitra
Koukouvinos, Georgios
Christianidis, Vasilios
Legaki, Evangelia
Giogli, Vasiliki
Panagiotopoulou, Konstantina
Taka, Styliani
Ekaterinidi, Zoi
Kakabakos, Sotirios
Raptis, Ioannis
Petrou, Panagiota
Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination
title Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination
title_full Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination
title_fullStr Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination
title_full_unstemmed Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination
title_short Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination
title_sort development of a point-of-care system based on white light reflectance spectroscopy: application in crp determination
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8394791/
https://www.ncbi.nlm.nih.gov/pubmed/34436070
http://dx.doi.org/10.3390/bios11080268
work_keys_str_mv AT tsounididimitra developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination
AT koukouvinosgeorgios developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination
AT christianidisvasilios developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination
AT legakievangelia developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination
AT gioglivasiliki developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination
AT panagiotopouloukonstantina developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination
AT takastyliani developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination
AT ekaterinidizoi developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination
AT kakabakossotirios developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination
AT raptisioannis developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination
AT petroupanagiota developmentofapointofcaresystembasedonwhitelightreflectancespectroscopyapplicationincrpdetermination