Cargando…

The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review

Background. Today there are many devices that can be used to study blood clotting disorders by identifying abnormalities in blood platelets. The Total Thrombus Formation Analysis System is an automated microchip flow chamber system that is used for the quantitative analysis of clot formation under b...

Descripción completa

Detalles Bibliográficos
Autores principales: Sikora, Joanna, Karczmarska-Wódzka, Aleksandra, Bugieda, Joanna, Sobczak, Przemysław
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8395324/
https://www.ncbi.nlm.nih.gov/pubmed/34445311
http://dx.doi.org/10.3390/ijms22168605
_version_ 1783744146845990912
author Sikora, Joanna
Karczmarska-Wódzka, Aleksandra
Bugieda, Joanna
Sobczak, Przemysław
author_facet Sikora, Joanna
Karczmarska-Wódzka, Aleksandra
Bugieda, Joanna
Sobczak, Przemysław
author_sort Sikora, Joanna
collection PubMed
description Background. Today there are many devices that can be used to study blood clotting disorders by identifying abnormalities in blood platelets. The Total Thrombus Formation Analysis System is an automated microchip flow chamber system that is used for the quantitative analysis of clot formation under blood flow conditions. For several years, researchers have been using a tool to analyse various clinical situations of patients to identify the properties and biochemical processes occurring within platelets and their microenvironment. Methods. An investigation of recent published literature was conducted based on PRISMA. This review includes 52 science papers directly related to the use of the Total Clot Formation Analysis System in relation to bleeding, surgery, platelet function assessment, anticoagulation monitoring, von Willebrand factor and others. Conclusion. Most available studies indicate that The Total Thrombus Formation Analysis System may be useful in diagnostic issues, with devices used to monitor therapy or as a significant tool for predicting bleeding events. However, T-TAS not that has the potential for diagnostic indications, but allows the direct observation of the flow and the interactions between blood cells, including the intensity and dynamics of clot formation. The device is expected to be of significant value for basic research to observe the interactions and changes within platelets and their microenvironment.
format Online
Article
Text
id pubmed-8395324
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83953242021-08-28 The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review Sikora, Joanna Karczmarska-Wódzka, Aleksandra Bugieda, Joanna Sobczak, Przemysław Int J Mol Sci Review Background. Today there are many devices that can be used to study blood clotting disorders by identifying abnormalities in blood platelets. The Total Thrombus Formation Analysis System is an automated microchip flow chamber system that is used for the quantitative analysis of clot formation under blood flow conditions. For several years, researchers have been using a tool to analyse various clinical situations of patients to identify the properties and biochemical processes occurring within platelets and their microenvironment. Methods. An investigation of recent published literature was conducted based on PRISMA. This review includes 52 science papers directly related to the use of the Total Clot Formation Analysis System in relation to bleeding, surgery, platelet function assessment, anticoagulation monitoring, von Willebrand factor and others. Conclusion. Most available studies indicate that The Total Thrombus Formation Analysis System may be useful in diagnostic issues, with devices used to monitor therapy or as a significant tool for predicting bleeding events. However, T-TAS not that has the potential for diagnostic indications, but allows the direct observation of the flow and the interactions between blood cells, including the intensity and dynamics of clot formation. The device is expected to be of significant value for basic research to observe the interactions and changes within platelets and their microenvironment. MDPI 2021-08-10 /pmc/articles/PMC8395324/ /pubmed/34445311 http://dx.doi.org/10.3390/ijms22168605 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Sikora, Joanna
Karczmarska-Wódzka, Aleksandra
Bugieda, Joanna
Sobczak, Przemysław
The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review
title The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review
title_full The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review
title_fullStr The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review
title_full_unstemmed The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review
title_short The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review
title_sort use of total thrombus formation analysis system as a tool to assess platelet function in bleeding and thrombosis risk—a systematic review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8395324/
https://www.ncbi.nlm.nih.gov/pubmed/34445311
http://dx.doi.org/10.3390/ijms22168605
work_keys_str_mv AT sikorajoanna theuseoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview
AT karczmarskawodzkaaleksandra theuseoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview
AT bugiedajoanna theuseoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview
AT sobczakprzemysław theuseoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview
AT sikorajoanna useoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview
AT karczmarskawodzkaaleksandra useoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview
AT bugiedajoanna useoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview
AT sobczakprzemysław useoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview