Cargando…
The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review
Background. Today there are many devices that can be used to study blood clotting disorders by identifying abnormalities in blood platelets. The Total Thrombus Formation Analysis System is an automated microchip flow chamber system that is used for the quantitative analysis of clot formation under b...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8395324/ https://www.ncbi.nlm.nih.gov/pubmed/34445311 http://dx.doi.org/10.3390/ijms22168605 |
_version_ | 1783744146845990912 |
---|---|
author | Sikora, Joanna Karczmarska-Wódzka, Aleksandra Bugieda, Joanna Sobczak, Przemysław |
author_facet | Sikora, Joanna Karczmarska-Wódzka, Aleksandra Bugieda, Joanna Sobczak, Przemysław |
author_sort | Sikora, Joanna |
collection | PubMed |
description | Background. Today there are many devices that can be used to study blood clotting disorders by identifying abnormalities in blood platelets. The Total Thrombus Formation Analysis System is an automated microchip flow chamber system that is used for the quantitative analysis of clot formation under blood flow conditions. For several years, researchers have been using a tool to analyse various clinical situations of patients to identify the properties and biochemical processes occurring within platelets and their microenvironment. Methods. An investigation of recent published literature was conducted based on PRISMA. This review includes 52 science papers directly related to the use of the Total Clot Formation Analysis System in relation to bleeding, surgery, platelet function assessment, anticoagulation monitoring, von Willebrand factor and others. Conclusion. Most available studies indicate that The Total Thrombus Formation Analysis System may be useful in diagnostic issues, with devices used to monitor therapy or as a significant tool for predicting bleeding events. However, T-TAS not that has the potential for diagnostic indications, but allows the direct observation of the flow and the interactions between blood cells, including the intensity and dynamics of clot formation. The device is expected to be of significant value for basic research to observe the interactions and changes within platelets and their microenvironment. |
format | Online Article Text |
id | pubmed-8395324 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83953242021-08-28 The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review Sikora, Joanna Karczmarska-Wódzka, Aleksandra Bugieda, Joanna Sobczak, Przemysław Int J Mol Sci Review Background. Today there are many devices that can be used to study blood clotting disorders by identifying abnormalities in blood platelets. The Total Thrombus Formation Analysis System is an automated microchip flow chamber system that is used for the quantitative analysis of clot formation under blood flow conditions. For several years, researchers have been using a tool to analyse various clinical situations of patients to identify the properties and biochemical processes occurring within platelets and their microenvironment. Methods. An investigation of recent published literature was conducted based on PRISMA. This review includes 52 science papers directly related to the use of the Total Clot Formation Analysis System in relation to bleeding, surgery, platelet function assessment, anticoagulation monitoring, von Willebrand factor and others. Conclusion. Most available studies indicate that The Total Thrombus Formation Analysis System may be useful in diagnostic issues, with devices used to monitor therapy or as a significant tool for predicting bleeding events. However, T-TAS not that has the potential for diagnostic indications, but allows the direct observation of the flow and the interactions between blood cells, including the intensity and dynamics of clot formation. The device is expected to be of significant value for basic research to observe the interactions and changes within platelets and their microenvironment. MDPI 2021-08-10 /pmc/articles/PMC8395324/ /pubmed/34445311 http://dx.doi.org/10.3390/ijms22168605 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Sikora, Joanna Karczmarska-Wódzka, Aleksandra Bugieda, Joanna Sobczak, Przemysław The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review |
title | The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review |
title_full | The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review |
title_fullStr | The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review |
title_full_unstemmed | The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review |
title_short | The Use of Total Thrombus Formation Analysis System as a Tool to Assess Platelet Function in Bleeding and Thrombosis Risk—A Systematic Review |
title_sort | use of total thrombus formation analysis system as a tool to assess platelet function in bleeding and thrombosis risk—a systematic review |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8395324/ https://www.ncbi.nlm.nih.gov/pubmed/34445311 http://dx.doi.org/10.3390/ijms22168605 |
work_keys_str_mv | AT sikorajoanna theuseoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview AT karczmarskawodzkaaleksandra theuseoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview AT bugiedajoanna theuseoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview AT sobczakprzemysław theuseoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview AT sikorajoanna useoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview AT karczmarskawodzkaaleksandra useoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview AT bugiedajoanna useoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview AT sobczakprzemysław useoftotalthrombusformationanalysissystemasatooltoassessplateletfunctioninbleedingandthrombosisriskasystematicreview |