Cargando…
Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination
Flow analysis is the science of performing quantitative analytical chemistry in flowing streams. Because of its efficiency and speed of analysis, capillary electrophoresis (CE) is a prospective method for the monitoring of a flow composition withdrawn from various processes (e.g., occurring in biore...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8398840/ https://www.ncbi.nlm.nih.gov/pubmed/34443507 http://dx.doi.org/10.3390/molecules26164918 |
_version_ | 1783744934346489856 |
---|---|
author | Kaljurand, Mihkel Saar-Reismaa, Piret Vaher, Merike Gorbatsova, Jelena Mazina-Šinkar, Jekaterina |
author_facet | Kaljurand, Mihkel Saar-Reismaa, Piret Vaher, Merike Gorbatsova, Jelena Mazina-Šinkar, Jekaterina |
author_sort | Kaljurand, Mihkel |
collection | PubMed |
description | Flow analysis is the science of performing quantitative analytical chemistry in flowing streams. Because of its efficiency and speed of analysis, capillary electrophoresis (CE) is a prospective method for the monitoring of a flow composition withdrawn from various processes (e.g., occurring in bioreactors, fermentations, enzymatic assays, and microdialysis samples). However, interfacing CE to a various flow of interest requires further study. In this paper, several ingenious approaches on interfacing flow from various chemical or bioprocesses to a capillary electrophoresis instrument are reviewed. Most of these interfaces can be described as computer-controlled autosamplers. Even though most of the described interfaces waste too many samples, many interesting and important applications of the devices are reported. However, the lack of commercially available devices prevents the wide application of CE for flow analysis. On the contrary, this fact opens up a potential avenue for future research in the field of flow sampling by CE. |
format | Online Article Text |
id | pubmed-8398840 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83988402021-08-29 Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination Kaljurand, Mihkel Saar-Reismaa, Piret Vaher, Merike Gorbatsova, Jelena Mazina-Šinkar, Jekaterina Molecules Review Flow analysis is the science of performing quantitative analytical chemistry in flowing streams. Because of its efficiency and speed of analysis, capillary electrophoresis (CE) is a prospective method for the monitoring of a flow composition withdrawn from various processes (e.g., occurring in bioreactors, fermentations, enzymatic assays, and microdialysis samples). However, interfacing CE to a various flow of interest requires further study. In this paper, several ingenious approaches on interfacing flow from various chemical or bioprocesses to a capillary electrophoresis instrument are reviewed. Most of these interfaces can be described as computer-controlled autosamplers. Even though most of the described interfaces waste too many samples, many interesting and important applications of the devices are reported. However, the lack of commercially available devices prevents the wide application of CE for flow analysis. On the contrary, this fact opens up a potential avenue for future research in the field of flow sampling by CE. MDPI 2021-08-13 /pmc/articles/PMC8398840/ /pubmed/34443507 http://dx.doi.org/10.3390/molecules26164918 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Kaljurand, Mihkel Saar-Reismaa, Piret Vaher, Merike Gorbatsova, Jelena Mazina-Šinkar, Jekaterina Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination |
title | Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination |
title_full | Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination |
title_fullStr | Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination |
title_full_unstemmed | Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination |
title_short | Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination |
title_sort | capillary electrophoresis as a monitoring tool for flow composition determination |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8398840/ https://www.ncbi.nlm.nih.gov/pubmed/34443507 http://dx.doi.org/10.3390/molecules26164918 |
work_keys_str_mv | AT kaljurandmihkel capillaryelectrophoresisasamonitoringtoolforflowcompositiondetermination AT saarreismaapiret capillaryelectrophoresisasamonitoringtoolforflowcompositiondetermination AT vahermerike capillaryelectrophoresisasamonitoringtoolforflowcompositiondetermination AT gorbatsovajelena capillaryelectrophoresisasamonitoringtoolforflowcompositiondetermination AT mazinasinkarjekaterina capillaryelectrophoresisasamonitoringtoolforflowcompositiondetermination |