Cargando…

Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination

Flow analysis is the science of performing quantitative analytical chemistry in flowing streams. Because of its efficiency and speed of analysis, capillary electrophoresis (CE) is a prospective method for the monitoring of a flow composition withdrawn from various processes (e.g., occurring in biore...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaljurand, Mihkel, Saar-Reismaa, Piret, Vaher, Merike, Gorbatsova, Jelena, Mazina-Šinkar, Jekaterina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8398840/
https://www.ncbi.nlm.nih.gov/pubmed/34443507
http://dx.doi.org/10.3390/molecules26164918
_version_ 1783744934346489856
author Kaljurand, Mihkel
Saar-Reismaa, Piret
Vaher, Merike
Gorbatsova, Jelena
Mazina-Šinkar, Jekaterina
author_facet Kaljurand, Mihkel
Saar-Reismaa, Piret
Vaher, Merike
Gorbatsova, Jelena
Mazina-Šinkar, Jekaterina
author_sort Kaljurand, Mihkel
collection PubMed
description Flow analysis is the science of performing quantitative analytical chemistry in flowing streams. Because of its efficiency and speed of analysis, capillary electrophoresis (CE) is a prospective method for the monitoring of a flow composition withdrawn from various processes (e.g., occurring in bioreactors, fermentations, enzymatic assays, and microdialysis samples). However, interfacing CE to a various flow of interest requires further study. In this paper, several ingenious approaches on interfacing flow from various chemical or bioprocesses to a capillary electrophoresis instrument are reviewed. Most of these interfaces can be described as computer-controlled autosamplers. Even though most of the described interfaces waste too many samples, many interesting and important applications of the devices are reported. However, the lack of commercially available devices prevents the wide application of CE for flow analysis. On the contrary, this fact opens up a potential avenue for future research in the field of flow sampling by CE.
format Online
Article
Text
id pubmed-8398840
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83988402021-08-29 Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination Kaljurand, Mihkel Saar-Reismaa, Piret Vaher, Merike Gorbatsova, Jelena Mazina-Šinkar, Jekaterina Molecules Review Flow analysis is the science of performing quantitative analytical chemistry in flowing streams. Because of its efficiency and speed of analysis, capillary electrophoresis (CE) is a prospective method for the monitoring of a flow composition withdrawn from various processes (e.g., occurring in bioreactors, fermentations, enzymatic assays, and microdialysis samples). However, interfacing CE to a various flow of interest requires further study. In this paper, several ingenious approaches on interfacing flow from various chemical or bioprocesses to a capillary electrophoresis instrument are reviewed. Most of these interfaces can be described as computer-controlled autosamplers. Even though most of the described interfaces waste too many samples, many interesting and important applications of the devices are reported. However, the lack of commercially available devices prevents the wide application of CE for flow analysis. On the contrary, this fact opens up a potential avenue for future research in the field of flow sampling by CE. MDPI 2021-08-13 /pmc/articles/PMC8398840/ /pubmed/34443507 http://dx.doi.org/10.3390/molecules26164918 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Kaljurand, Mihkel
Saar-Reismaa, Piret
Vaher, Merike
Gorbatsova, Jelena
Mazina-Šinkar, Jekaterina
Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination
title Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination
title_full Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination
title_fullStr Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination
title_full_unstemmed Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination
title_short Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination
title_sort capillary electrophoresis as a monitoring tool for flow composition determination
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8398840/
https://www.ncbi.nlm.nih.gov/pubmed/34443507
http://dx.doi.org/10.3390/molecules26164918
work_keys_str_mv AT kaljurandmihkel capillaryelectrophoresisasamonitoringtoolforflowcompositiondetermination
AT saarreismaapiret capillaryelectrophoresisasamonitoringtoolforflowcompositiondetermination
AT vahermerike capillaryelectrophoresisasamonitoringtoolforflowcompositiondetermination
AT gorbatsovajelena capillaryelectrophoresisasamonitoringtoolforflowcompositiondetermination
AT mazinasinkarjekaterina capillaryelectrophoresisasamonitoringtoolforflowcompositiondetermination