Cargando…

Optimal Combination of Mixing Units Using the Design of Experiments Method

A passive micromixer was designed by combining two mixing units: the cross-channel split and recombined (CC-SAR) and a mixing cell with baffles (MC-B). The passive micromixer was comprised of eight mixing slots that corresponded to four combination units; two mixing slots were grouped as one combina...

Descripción completa

Detalles Bibliográficos
Autores principales: Juraeva, Makhsuda, Kang, Dong-Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8398973/
https://www.ncbi.nlm.nih.gov/pubmed/34442607
http://dx.doi.org/10.3390/mi12080985
_version_ 1783744965969444864
author Juraeva, Makhsuda
Kang, Dong-Jin
author_facet Juraeva, Makhsuda
Kang, Dong-Jin
author_sort Juraeva, Makhsuda
collection PubMed
description A passive micromixer was designed by combining two mixing units: the cross-channel split and recombined (CC-SAR) and a mixing cell with baffles (MC-B). The passive micromixer was comprised of eight mixing slots that corresponded to four combination units; two mixing slots were grouped as one combination unit. The combination of the two mixing units was based on four combination schemes: (A) first mixing unit, (B) first combination unit, (C) first combination module, and (D) second combination module. The statistical significance of the four combination schemes was analyzed using analysis of variance (ANOVA) in terms of the degree of mixing (DOM) and mixing energy cost (MEC). The DOM and MEC were simulated numerically for three Reynolds numbers (Re = 0.5, 2, and 50), representing three mixing regimes. The combination scheme (B), using different mixing units in the first two mixing slots, was significant for Re = 2 and 50. The four combination schemes had little effect on the mixing performance of a passive micromixer operating in the mixing regime of molecular dominance. The combination scheme (B) was generalized to arbitrary mixing slots, and its significance was analyzed for Re = 2 and 50. The general combination scheme meant two different mixing units in two consecutive mixing slots. The numerical simulation results showed that the general combination scheme was statistically significant in the first three combination units for Re = 2, and significant in the first two combination units for Re = 50. The combined micromixer based on the general combination scheme throughout the entire micromixer showed the best mixing performance over a wide range of Reynolds numbers, compared to other micromixers that did not adopt completely the general combination scheme. The most significant enhancement due to the general combination scheme was observed in the transition mixing scheme and was negligible in the molecular dominance scheme. The combination order was less significant after three combination units.
format Online
Article
Text
id pubmed-8398973
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83989732021-08-29 Optimal Combination of Mixing Units Using the Design of Experiments Method Juraeva, Makhsuda Kang, Dong-Jin Micromachines (Basel) Article A passive micromixer was designed by combining two mixing units: the cross-channel split and recombined (CC-SAR) and a mixing cell with baffles (MC-B). The passive micromixer was comprised of eight mixing slots that corresponded to four combination units; two mixing slots were grouped as one combination unit. The combination of the two mixing units was based on four combination schemes: (A) first mixing unit, (B) first combination unit, (C) first combination module, and (D) second combination module. The statistical significance of the four combination schemes was analyzed using analysis of variance (ANOVA) in terms of the degree of mixing (DOM) and mixing energy cost (MEC). The DOM and MEC were simulated numerically for three Reynolds numbers (Re = 0.5, 2, and 50), representing three mixing regimes. The combination scheme (B), using different mixing units in the first two mixing slots, was significant for Re = 2 and 50. The four combination schemes had little effect on the mixing performance of a passive micromixer operating in the mixing regime of molecular dominance. The combination scheme (B) was generalized to arbitrary mixing slots, and its significance was analyzed for Re = 2 and 50. The general combination scheme meant two different mixing units in two consecutive mixing slots. The numerical simulation results showed that the general combination scheme was statistically significant in the first three combination units for Re = 2, and significant in the first two combination units for Re = 50. The combined micromixer based on the general combination scheme throughout the entire micromixer showed the best mixing performance over a wide range of Reynolds numbers, compared to other micromixers that did not adopt completely the general combination scheme. The most significant enhancement due to the general combination scheme was observed in the transition mixing scheme and was negligible in the molecular dominance scheme. The combination order was less significant after three combination units. MDPI 2021-08-19 /pmc/articles/PMC8398973/ /pubmed/34442607 http://dx.doi.org/10.3390/mi12080985 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Juraeva, Makhsuda
Kang, Dong-Jin
Optimal Combination of Mixing Units Using the Design of Experiments Method
title Optimal Combination of Mixing Units Using the Design of Experiments Method
title_full Optimal Combination of Mixing Units Using the Design of Experiments Method
title_fullStr Optimal Combination of Mixing Units Using the Design of Experiments Method
title_full_unstemmed Optimal Combination of Mixing Units Using the Design of Experiments Method
title_short Optimal Combination of Mixing Units Using the Design of Experiments Method
title_sort optimal combination of mixing units using the design of experiments method
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8398973/
https://www.ncbi.nlm.nih.gov/pubmed/34442607
http://dx.doi.org/10.3390/mi12080985
work_keys_str_mv AT juraevamakhsuda optimalcombinationofmixingunitsusingthedesignofexperimentsmethod
AT kangdongjin optimalcombinationofmixingunitsusingthedesignofexperimentsmethod