Cargando…
A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone
The accuracy of implant placement with a fully guided digital template can be influenced by many factors, such as arch difference, alveolar bone density, timing of implant placement and open flap. The purpose of this article was to evaluate the factors presumptively affecting the accuracy of implant...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8399113/ https://www.ncbi.nlm.nih.gov/pubmed/34443154 http://dx.doi.org/10.3390/ma14164631 |
_version_ | 1783744998184845312 |
---|---|
author | Huang, Lirong Zhang, Xiaoqing Mo, Anchun |
author_facet | Huang, Lirong Zhang, Xiaoqing Mo, Anchun |
author_sort | Huang, Lirong |
collection | PubMed |
description | The accuracy of implant placement with a fully guided digital template can be influenced by many factors, such as arch difference, alveolar bone density, timing of implant placement and open flap. The purpose of this article was to evaluate the factors presumptively affecting the accuracy of implant placement assisted by the fully guided template in the anterior zone. In 40 patients with missing anterior teeth, a total of 52 implants were placed with tooth-borne, fully guided templates after CBCT evaluation, in West China Hospital of Stomatology, Sichuan University. After overlapping the pre-and post-operative DICOM data, measurements were taken in the dental implant planning software (Nobel Clinician(®)) to calculate linear and angular deviations between virtual placement plan and actual implant placement. Grouping was categorized according to three factors that possibly have an influence on accuracy: arch type (maxilla/mandible), timing of implant placement (immediate/delayed), surgical technique (open flap/flapless). The data was analyzed with independent sample t-test (p < 0.05). The results showed that the apical, coronal, depth and angular mean deviations of implant positions in anterior zone were 1.13 ± 0.39 mm, 0.86 ± 0.33 mm, 0.41 ± 0.66 mm, 3.32 ± 1.65° with the fully guided templates. The accuracy at apex level, coronal level and the angulation were similar between the maxilla and mandible, and the magnitude of all four deviations between immediate and delayed implantation, open flap and flapless technique were small. No statistically significant difference was observed (p > 0.05). Whereas there was significant difference in depth deviation between maxilla and mandible (p < 0.05). Conclusively, the implant site, alveolar bone density, timing of implant placement and surgical techniques merely compromise the implant placement accuracy under the assistance of a fully guided template. |
format | Online Article Text |
id | pubmed-8399113 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83991132021-08-29 A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone Huang, Lirong Zhang, Xiaoqing Mo, Anchun Materials (Basel) Article The accuracy of implant placement with a fully guided digital template can be influenced by many factors, such as arch difference, alveolar bone density, timing of implant placement and open flap. The purpose of this article was to evaluate the factors presumptively affecting the accuracy of implant placement assisted by the fully guided template in the anterior zone. In 40 patients with missing anterior teeth, a total of 52 implants were placed with tooth-borne, fully guided templates after CBCT evaluation, in West China Hospital of Stomatology, Sichuan University. After overlapping the pre-and post-operative DICOM data, measurements were taken in the dental implant planning software (Nobel Clinician(®)) to calculate linear and angular deviations between virtual placement plan and actual implant placement. Grouping was categorized according to three factors that possibly have an influence on accuracy: arch type (maxilla/mandible), timing of implant placement (immediate/delayed), surgical technique (open flap/flapless). The data was analyzed with independent sample t-test (p < 0.05). The results showed that the apical, coronal, depth and angular mean deviations of implant positions in anterior zone were 1.13 ± 0.39 mm, 0.86 ± 0.33 mm, 0.41 ± 0.66 mm, 3.32 ± 1.65° with the fully guided templates. The accuracy at apex level, coronal level and the angulation were similar between the maxilla and mandible, and the magnitude of all four deviations between immediate and delayed implantation, open flap and flapless technique were small. No statistically significant difference was observed (p > 0.05). Whereas there was significant difference in depth deviation between maxilla and mandible (p < 0.05). Conclusively, the implant site, alveolar bone density, timing of implant placement and surgical techniques merely compromise the implant placement accuracy under the assistance of a fully guided template. MDPI 2021-08-17 /pmc/articles/PMC8399113/ /pubmed/34443154 http://dx.doi.org/10.3390/ma14164631 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Huang, Lirong Zhang, Xiaoqing Mo, Anchun A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone |
title | A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone |
title_full | A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone |
title_fullStr | A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone |
title_full_unstemmed | A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone |
title_short | A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone |
title_sort | retrospective study on the transferring accuracy of a fully guided digital template in the anterior zone |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8399113/ https://www.ncbi.nlm.nih.gov/pubmed/34443154 http://dx.doi.org/10.3390/ma14164631 |
work_keys_str_mv | AT huanglirong aretrospectivestudyonthetransferringaccuracyofafullyguideddigitaltemplateintheanteriorzone AT zhangxiaoqing aretrospectivestudyonthetransferringaccuracyofafullyguideddigitaltemplateintheanteriorzone AT moanchun aretrospectivestudyonthetransferringaccuracyofafullyguideddigitaltemplateintheanteriorzone AT huanglirong retrospectivestudyonthetransferringaccuracyofafullyguideddigitaltemplateintheanteriorzone AT zhangxiaoqing retrospectivestudyonthetransferringaccuracyofafullyguideddigitaltemplateintheanteriorzone AT moanchun retrospectivestudyonthetransferringaccuracyofafullyguideddigitaltemplateintheanteriorzone |