Cargando…

Analytical Evaluation of the Ideal Strategy for High-Throughput Flow Injection Analysis by Tandem Mass Spectrometry in Routine Newborn Screening

The introduction of tandem mass spectrometry (MS/MS) to clinical laboratories and the advent of expanded newborn screening (NBS) were crucial changes to public health programs worldwide. Speed, robustness, accuracy, selectivity, and specificity of analysis are all requirements of expanded NBS and ar...

Descripción completa

Detalles Bibliográficos
Autores principales: Cicalini, Ilaria, Valentinuzzi, Silvia, Pieragostino, Damiana, Consalvo, Ada, Zucchelli, Mirco, Donzelli, Simone, Ambrogi, Davide, Brown, Heather A., Calton, Lisa J., Stuppia, Liborio, De Laurenzi, Vincenzo, Del Boccio, Piero, Rossi, Claudia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8399422/
https://www.ncbi.nlm.nih.gov/pubmed/34436414
http://dx.doi.org/10.3390/metabo11080473
_version_ 1783745072634789888
author Cicalini, Ilaria
Valentinuzzi, Silvia
Pieragostino, Damiana
Consalvo, Ada
Zucchelli, Mirco
Donzelli, Simone
Ambrogi, Davide
Brown, Heather A.
Calton, Lisa J.
Stuppia, Liborio
De Laurenzi, Vincenzo
Del Boccio, Piero
Rossi, Claudia
author_facet Cicalini, Ilaria
Valentinuzzi, Silvia
Pieragostino, Damiana
Consalvo, Ada
Zucchelli, Mirco
Donzelli, Simone
Ambrogi, Davide
Brown, Heather A.
Calton, Lisa J.
Stuppia, Liborio
De Laurenzi, Vincenzo
Del Boccio, Piero
Rossi, Claudia
author_sort Cicalini, Ilaria
collection PubMed
description The introduction of tandem mass spectrometry (MS/MS) to clinical laboratories and the advent of expanded newborn screening (NBS) were crucial changes to public health programs worldwide. Speed, robustness, accuracy, selectivity, and specificity of analysis are all requirements of expanded NBS and are needed to minimize false positive results risks, to possibly eliminate false negatives, and to improve the positive predictive value of NBS. In this study, we firstly evaluated the analytical performances of the RenataDX Screening System, a fully integrated flow-injection MS/MS (FIA-MS/MS) IVD system for high-throughput dried blood spot (DBS) analysis in a routine NBS laboratory. Since a choice of several commercial NBS kits is available, we sought to compare NeoBase(TM) 2 (PerkinElmer(®)) and MassChrom(®) (Chromsystems) non-derivatized kits on the RenataDX platform by evaluating their analytical performances. Moreover, we verified the degree of correlation between data obtained by the two different NBS MS/MS kits by FIA-MS/MS of over 500 samples. Our data suggest that both methods correlate well with clinically insignificant differences that do not impact the NBS result. Finally, while NeoBase™ 2 offers an easier and faster sample preparation, MassChrom(®) provides a cleaner sample extract which empirically should improve instrument reliability.
format Online
Article
Text
id pubmed-8399422
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83994222021-08-29 Analytical Evaluation of the Ideal Strategy for High-Throughput Flow Injection Analysis by Tandem Mass Spectrometry in Routine Newborn Screening Cicalini, Ilaria Valentinuzzi, Silvia Pieragostino, Damiana Consalvo, Ada Zucchelli, Mirco Donzelli, Simone Ambrogi, Davide Brown, Heather A. Calton, Lisa J. Stuppia, Liborio De Laurenzi, Vincenzo Del Boccio, Piero Rossi, Claudia Metabolites Article The introduction of tandem mass spectrometry (MS/MS) to clinical laboratories and the advent of expanded newborn screening (NBS) were crucial changes to public health programs worldwide. Speed, robustness, accuracy, selectivity, and specificity of analysis are all requirements of expanded NBS and are needed to minimize false positive results risks, to possibly eliminate false negatives, and to improve the positive predictive value of NBS. In this study, we firstly evaluated the analytical performances of the RenataDX Screening System, a fully integrated flow-injection MS/MS (FIA-MS/MS) IVD system for high-throughput dried blood spot (DBS) analysis in a routine NBS laboratory. Since a choice of several commercial NBS kits is available, we sought to compare NeoBase(TM) 2 (PerkinElmer(®)) and MassChrom(®) (Chromsystems) non-derivatized kits on the RenataDX platform by evaluating their analytical performances. Moreover, we verified the degree of correlation between data obtained by the two different NBS MS/MS kits by FIA-MS/MS of over 500 samples. Our data suggest that both methods correlate well with clinically insignificant differences that do not impact the NBS result. Finally, while NeoBase™ 2 offers an easier and faster sample preparation, MassChrom(®) provides a cleaner sample extract which empirically should improve instrument reliability. MDPI 2021-07-22 /pmc/articles/PMC8399422/ /pubmed/34436414 http://dx.doi.org/10.3390/metabo11080473 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cicalini, Ilaria
Valentinuzzi, Silvia
Pieragostino, Damiana
Consalvo, Ada
Zucchelli, Mirco
Donzelli, Simone
Ambrogi, Davide
Brown, Heather A.
Calton, Lisa J.
Stuppia, Liborio
De Laurenzi, Vincenzo
Del Boccio, Piero
Rossi, Claudia
Analytical Evaluation of the Ideal Strategy for High-Throughput Flow Injection Analysis by Tandem Mass Spectrometry in Routine Newborn Screening
title Analytical Evaluation of the Ideal Strategy for High-Throughput Flow Injection Analysis by Tandem Mass Spectrometry in Routine Newborn Screening
title_full Analytical Evaluation of the Ideal Strategy for High-Throughput Flow Injection Analysis by Tandem Mass Spectrometry in Routine Newborn Screening
title_fullStr Analytical Evaluation of the Ideal Strategy for High-Throughput Flow Injection Analysis by Tandem Mass Spectrometry in Routine Newborn Screening
title_full_unstemmed Analytical Evaluation of the Ideal Strategy for High-Throughput Flow Injection Analysis by Tandem Mass Spectrometry in Routine Newborn Screening
title_short Analytical Evaluation of the Ideal Strategy for High-Throughput Flow Injection Analysis by Tandem Mass Spectrometry in Routine Newborn Screening
title_sort analytical evaluation of the ideal strategy for high-throughput flow injection analysis by tandem mass spectrometry in routine newborn screening
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8399422/
https://www.ncbi.nlm.nih.gov/pubmed/34436414
http://dx.doi.org/10.3390/metabo11080473
work_keys_str_mv AT cicaliniilaria analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT valentinuzzisilvia analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT pieragostinodamiana analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT consalvoada analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT zucchellimirco analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT donzellisimone analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT ambrogidavide analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT brownheathera analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT caltonlisaj analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT stuppialiborio analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT delaurenzivincenzo analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT delbocciopiero analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening
AT rossiclaudia analyticalevaluationoftheidealstrategyforhighthroughputflowinjectionanalysisbytandemmassspectrometryinroutinenewbornscreening