Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement
Terahertz time-domain spectroscopy systems driven by monolithic mode-locked laser diodes (MLLDs) exhibit bandwidths exceeding 1 THz and a peak dynamic range that can compete with other state-of-the-art systems. Their main difference compared to fiber-laser-driven systems is their ultra-high repetiti...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8400559/ https://www.ncbi.nlm.nih.gov/pubmed/34450830 http://dx.doi.org/10.3390/s21165389 |
_version_ | 1783745343467290624 |
---|---|
author | Kolpatzeck, Kevin Liu, Xuan Häring, Lars Balzer, Jan C. Czylwik, Andreas |
author_facet | Kolpatzeck, Kevin Liu, Xuan Häring, Lars Balzer, Jan C. Czylwik, Andreas |
author_sort | Kolpatzeck, Kevin |
collection | PubMed |
description | Terahertz time-domain spectroscopy systems driven by monolithic mode-locked laser diodes (MLLDs) exhibit bandwidths exceeding 1 THz and a peak dynamic range that can compete with other state-of-the-art systems. Their main difference compared to fiber-laser-driven systems is their ultra-high repetition rate of typically dozens of GHz. This makes them interesting for applications where the length of the terahertz path may not be precisely known and it enables the use of a very short and potentially fast optical delay unit. However, the phase accuracy of the system is limited by the accuracy with which the delay axes of subsequent measurements are synchronized. In this work, we utilize an all-fiber approach that uses the optical signal from the MLLD in a Mach–Zehnder interferometer to generate a reference signal that we use to synchronize the detected terahertz signals. We demonstrate transmission-mode thickness measurements of stacked layers of [Formula: see text] m thick low-density polyethylene (LDPE) films. |
format | Online Article Text |
id | pubmed-8400559 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84005592021-08-29 Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement Kolpatzeck, Kevin Liu, Xuan Häring, Lars Balzer, Jan C. Czylwik, Andreas Sensors (Basel) Article Terahertz time-domain spectroscopy systems driven by monolithic mode-locked laser diodes (MLLDs) exhibit bandwidths exceeding 1 THz and a peak dynamic range that can compete with other state-of-the-art systems. Their main difference compared to fiber-laser-driven systems is their ultra-high repetition rate of typically dozens of GHz. This makes them interesting for applications where the length of the terahertz path may not be precisely known and it enables the use of a very short and potentially fast optical delay unit. However, the phase accuracy of the system is limited by the accuracy with which the delay axes of subsequent measurements are synchronized. In this work, we utilize an all-fiber approach that uses the optical signal from the MLLD in a Mach–Zehnder interferometer to generate a reference signal that we use to synchronize the detected terahertz signals. We demonstrate transmission-mode thickness measurements of stacked layers of [Formula: see text] m thick low-density polyethylene (LDPE) films. MDPI 2021-08-10 /pmc/articles/PMC8400559/ /pubmed/34450830 http://dx.doi.org/10.3390/s21165389 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kolpatzeck, Kevin Liu, Xuan Häring, Lars Balzer, Jan C. Czylwik, Andreas Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement |
title | Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement |
title_full | Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement |
title_fullStr | Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement |
title_full_unstemmed | Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement |
title_short | Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement |
title_sort | ultra-high repetition rate terahertz time-domain spectroscopy for micrometer layer thickness measurement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8400559/ https://www.ncbi.nlm.nih.gov/pubmed/34450830 http://dx.doi.org/10.3390/s21165389 |
work_keys_str_mv | AT kolpatzeckkevin ultrahighrepetitionrateterahertztimedomainspectroscopyformicrometerlayerthicknessmeasurement AT liuxuan ultrahighrepetitionrateterahertztimedomainspectroscopyformicrometerlayerthicknessmeasurement AT haringlars ultrahighrepetitionrateterahertztimedomainspectroscopyformicrometerlayerthicknessmeasurement AT balzerjanc ultrahighrepetitionrateterahertztimedomainspectroscopyformicrometerlayerthicknessmeasurement AT czylwikandreas ultrahighrepetitionrateterahertztimedomainspectroscopyformicrometerlayerthicknessmeasurement |