Cargando…

Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement

Terahertz time-domain spectroscopy systems driven by monolithic mode-locked laser diodes (MLLDs) exhibit bandwidths exceeding 1 THz and a peak dynamic range that can compete with other state-of-the-art systems. Their main difference compared to fiber-laser-driven systems is their ultra-high repetiti...

Descripción completa

Detalles Bibliográficos
Autores principales: Kolpatzeck, Kevin, Liu, Xuan, Häring, Lars, Balzer, Jan C., Czylwik, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8400559/
https://www.ncbi.nlm.nih.gov/pubmed/34450830
http://dx.doi.org/10.3390/s21165389
_version_ 1783745343467290624
author Kolpatzeck, Kevin
Liu, Xuan
Häring, Lars
Balzer, Jan C.
Czylwik, Andreas
author_facet Kolpatzeck, Kevin
Liu, Xuan
Häring, Lars
Balzer, Jan C.
Czylwik, Andreas
author_sort Kolpatzeck, Kevin
collection PubMed
description Terahertz time-domain spectroscopy systems driven by monolithic mode-locked laser diodes (MLLDs) exhibit bandwidths exceeding 1 THz and a peak dynamic range that can compete with other state-of-the-art systems. Their main difference compared to fiber-laser-driven systems is their ultra-high repetition rate of typically dozens of GHz. This makes them interesting for applications where the length of the terahertz path may not be precisely known and it enables the use of a very short and potentially fast optical delay unit. However, the phase accuracy of the system is limited by the accuracy with which the delay axes of subsequent measurements are synchronized. In this work, we utilize an all-fiber approach that uses the optical signal from the MLLD in a Mach–Zehnder interferometer to generate a reference signal that we use to synchronize the detected terahertz signals. We demonstrate transmission-mode thickness measurements of stacked layers of [Formula: see text] m thick low-density polyethylene (LDPE) films.
format Online
Article
Text
id pubmed-8400559
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84005592021-08-29 Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement Kolpatzeck, Kevin Liu, Xuan Häring, Lars Balzer, Jan C. Czylwik, Andreas Sensors (Basel) Article Terahertz time-domain spectroscopy systems driven by monolithic mode-locked laser diodes (MLLDs) exhibit bandwidths exceeding 1 THz and a peak dynamic range that can compete with other state-of-the-art systems. Their main difference compared to fiber-laser-driven systems is their ultra-high repetition rate of typically dozens of GHz. This makes them interesting for applications where the length of the terahertz path may not be precisely known and it enables the use of a very short and potentially fast optical delay unit. However, the phase accuracy of the system is limited by the accuracy with which the delay axes of subsequent measurements are synchronized. In this work, we utilize an all-fiber approach that uses the optical signal from the MLLD in a Mach–Zehnder interferometer to generate a reference signal that we use to synchronize the detected terahertz signals. We demonstrate transmission-mode thickness measurements of stacked layers of [Formula: see text] m thick low-density polyethylene (LDPE) films. MDPI 2021-08-10 /pmc/articles/PMC8400559/ /pubmed/34450830 http://dx.doi.org/10.3390/s21165389 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kolpatzeck, Kevin
Liu, Xuan
Häring, Lars
Balzer, Jan C.
Czylwik, Andreas
Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement
title Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement
title_full Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement
title_fullStr Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement
title_full_unstemmed Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement
title_short Ultra-High Repetition Rate Terahertz Time-Domain Spectroscopy for Micrometer Layer Thickness Measurement
title_sort ultra-high repetition rate terahertz time-domain spectroscopy for micrometer layer thickness measurement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8400559/
https://www.ncbi.nlm.nih.gov/pubmed/34450830
http://dx.doi.org/10.3390/s21165389
work_keys_str_mv AT kolpatzeckkevin ultrahighrepetitionrateterahertztimedomainspectroscopyformicrometerlayerthicknessmeasurement
AT liuxuan ultrahighrepetitionrateterahertztimedomainspectroscopyformicrometerlayerthicknessmeasurement
AT haringlars ultrahighrepetitionrateterahertztimedomainspectroscopyformicrometerlayerthicknessmeasurement
AT balzerjanc ultrahighrepetitionrateterahertztimedomainspectroscopyformicrometerlayerthicknessmeasurement
AT czylwikandreas ultrahighrepetitionrateterahertztimedomainspectroscopyformicrometerlayerthicknessmeasurement