Cargando…
Implant-Related Complications Using Uniaxial Implants In Pediatric Spinal Deformity Surgery
Introduction: The successful surgical treatment of paediatric spinal deformity relies on robust anchors to achieve correction. Uniaxial pedicle screws are designed with articulation between the screw head and screw shaft, thus reducing the risk of anchor failure whilst permitting corrective manoeuvr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8400604/ https://www.ncbi.nlm.nih.gov/pubmed/34471573 http://dx.doi.org/10.7759/cureus.16715 |
_version_ | 1783745354055811072 |
---|---|
author | Machida, Masayoshi Rocos, Brett Lebel, David E Nallet, Jeremie Zeller, Reinhard |
author_facet | Machida, Masayoshi Rocos, Brett Lebel, David E Nallet, Jeremie Zeller, Reinhard |
author_sort | Machida, Masayoshi |
collection | PubMed |
description | Introduction: The successful surgical treatment of paediatric spinal deformity relies on robust anchors to achieve correction. Uniaxial pedicle screws are designed with articulation between the screw head and screw shaft, thus reducing the risk of anchor failure whilst permitting corrective manoeuvres. The purpose of this study was to describe the incidence, nature, and chronology of implant-related complications in pediatric spinal deformity treated with uniaxial pedicle screws. Methods: A retrospective radiographic analysis was carried out on paediatric patients treated for spinal deformity with more than two years of follow-up. Each was treated with posterior instrumented spinal fusion (PISF) using a uniaxial pedicle screw system by a single surgeon at a single institution. Surgical records, post-operative radiographs, and follow-up documentation were scrutinised for details of the implants used, implant failure, and revision procedures. Results: Three hundred and eighty-nine eligible patients with a mean follow-up of 3.3 years were identified. The mean anchor density was 1.7. Seven implant complications were observed. Early complications (<12 months) occurred in four cases and late (>12 months) in three cases. None of the early complications were associated with non-union. Two early and two late complications required revision surgery to manage implant failure and non-union. Patients who underwent fusion across the lumbosacral junction showed a higher than expected rate of implant-related complication (P=0.02). Conclusion: This study shows that there is a rate of implant-related failure of 1.8% after PISF with uniaxial implants in pediatric spinal deformities. There is a distinction between early and late implant-related complications, with early failure being due to loss of construct integrity, whereas late failure is due to pseudarthrosis and construct fatigue. |
format | Online Article Text |
id | pubmed-8400604 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-84006042021-08-31 Implant-Related Complications Using Uniaxial Implants In Pediatric Spinal Deformity Surgery Machida, Masayoshi Rocos, Brett Lebel, David E Nallet, Jeremie Zeller, Reinhard Cureus Pediatric Surgery Introduction: The successful surgical treatment of paediatric spinal deformity relies on robust anchors to achieve correction. Uniaxial pedicle screws are designed with articulation between the screw head and screw shaft, thus reducing the risk of anchor failure whilst permitting corrective manoeuvres. The purpose of this study was to describe the incidence, nature, and chronology of implant-related complications in pediatric spinal deformity treated with uniaxial pedicle screws. Methods: A retrospective radiographic analysis was carried out on paediatric patients treated for spinal deformity with more than two years of follow-up. Each was treated with posterior instrumented spinal fusion (PISF) using a uniaxial pedicle screw system by a single surgeon at a single institution. Surgical records, post-operative radiographs, and follow-up documentation were scrutinised for details of the implants used, implant failure, and revision procedures. Results: Three hundred and eighty-nine eligible patients with a mean follow-up of 3.3 years were identified. The mean anchor density was 1.7. Seven implant complications were observed. Early complications (<12 months) occurred in four cases and late (>12 months) in three cases. None of the early complications were associated with non-union. Two early and two late complications required revision surgery to manage implant failure and non-union. Patients who underwent fusion across the lumbosacral junction showed a higher than expected rate of implant-related complication (P=0.02). Conclusion: This study shows that there is a rate of implant-related failure of 1.8% after PISF with uniaxial implants in pediatric spinal deformities. There is a distinction between early and late implant-related complications, with early failure being due to loss of construct integrity, whereas late failure is due to pseudarthrosis and construct fatigue. Cureus 2021-07-29 /pmc/articles/PMC8400604/ /pubmed/34471573 http://dx.doi.org/10.7759/cureus.16715 Text en Copyright © 2021, Machida et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Pediatric Surgery Machida, Masayoshi Rocos, Brett Lebel, David E Nallet, Jeremie Zeller, Reinhard Implant-Related Complications Using Uniaxial Implants In Pediatric Spinal Deformity Surgery |
title | Implant-Related Complications Using Uniaxial Implants In Pediatric Spinal Deformity Surgery |
title_full | Implant-Related Complications Using Uniaxial Implants In Pediatric Spinal Deformity Surgery |
title_fullStr | Implant-Related Complications Using Uniaxial Implants In Pediatric Spinal Deformity Surgery |
title_full_unstemmed | Implant-Related Complications Using Uniaxial Implants In Pediatric Spinal Deformity Surgery |
title_short | Implant-Related Complications Using Uniaxial Implants In Pediatric Spinal Deformity Surgery |
title_sort | implant-related complications using uniaxial implants in pediatric spinal deformity surgery |
topic | Pediatric Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8400604/ https://www.ncbi.nlm.nih.gov/pubmed/34471573 http://dx.doi.org/10.7759/cureus.16715 |
work_keys_str_mv | AT machidamasayoshi implantrelatedcomplicationsusinguniaxialimplantsinpediatricspinaldeformitysurgery AT rocosbrett implantrelatedcomplicationsusinguniaxialimplantsinpediatricspinaldeformitysurgery AT lebeldavide implantrelatedcomplicationsusinguniaxialimplantsinpediatricspinaldeformitysurgery AT nalletjeremie implantrelatedcomplicationsusinguniaxialimplantsinpediatricspinaldeformitysurgery AT zellerreinhard implantrelatedcomplicationsusinguniaxialimplantsinpediatricspinaldeformitysurgery |