A Pressure-Pad-Embedded Treadmill Yields Time-Dependent Errors in Estimating Ground Reaction Force during Walking

Accurate and reliable vertical ground reaction force (VGRF) measurement is essential in various biomechanical and clinical studies. Recently, pressure–pad-embedded treadmills have been widely used for VGRF measurement as a relatively less expensive option than the force platform-mounted treadmills....

Descripción completa

Detalles Bibliográficos
Autores principales: Pathak, Prabhat, Ahn, Jooeun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8401449/
https://www.ncbi.nlm.nih.gov/pubmed/34450953
http://dx.doi.org/10.3390/s21165511
_version_ 1783745553906008064
author Pathak, Prabhat
Ahn, Jooeun
author_facet Pathak, Prabhat
Ahn, Jooeun
author_sort Pathak, Prabhat
collection PubMed
description Accurate and reliable vertical ground reaction force (VGRF) measurement is essential in various biomechanical and clinical studies. Recently, pressure–pad-embedded treadmills have been widely used for VGRF measurement as a relatively less expensive option than the force platform-mounted treadmills. Prior studies have shown that the popular Zebris treadmill is reliable when used to measure peak VGRF for short walking sessions. However, comprehensive evaluation of human walking requires information of gait parameters over sufficient gait cycles. In this study, we quantify the long-term temporal changes in VGRF values measured by the Zebris treadmill. Twenty participants walked on the treadmill for 10 min twice, with 10 min rest between trials. We found an evident decline in the measured VGRF and impulse over time for both trials. The Zebris system also consistently yielded the lower VGRF values during the second trials. These results indicate that the Zebris treadmill is unreliable in measuring VGRF during walking, and a 10 min break is not enough for the embedded sensors to recover their sensitivity. We provided a way to resolve these time-dependent errors; using the impulse-momentum theorem and collected kinematics of the participants, we formulated a curve-fitting model encapsulating the growing VGRF estimation error.
format Online
Article
Text
id pubmed-8401449
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84014492021-08-29 A Pressure-Pad-Embedded Treadmill Yields Time-Dependent Errors in Estimating Ground Reaction Force during Walking Pathak, Prabhat Ahn, Jooeun Sensors (Basel) Article Accurate and reliable vertical ground reaction force (VGRF) measurement is essential in various biomechanical and clinical studies. Recently, pressure–pad-embedded treadmills have been widely used for VGRF measurement as a relatively less expensive option than the force platform-mounted treadmills. Prior studies have shown that the popular Zebris treadmill is reliable when used to measure peak VGRF for short walking sessions. However, comprehensive evaluation of human walking requires information of gait parameters over sufficient gait cycles. In this study, we quantify the long-term temporal changes in VGRF values measured by the Zebris treadmill. Twenty participants walked on the treadmill for 10 min twice, with 10 min rest between trials. We found an evident decline in the measured VGRF and impulse over time for both trials. The Zebris system also consistently yielded the lower VGRF values during the second trials. These results indicate that the Zebris treadmill is unreliable in measuring VGRF during walking, and a 10 min break is not enough for the embedded sensors to recover their sensitivity. We provided a way to resolve these time-dependent errors; using the impulse-momentum theorem and collected kinematics of the participants, we formulated a curve-fitting model encapsulating the growing VGRF estimation error. MDPI 2021-08-17 /pmc/articles/PMC8401449/ /pubmed/34450953 http://dx.doi.org/10.3390/s21165511 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pathak, Prabhat
Ahn, Jooeun
A Pressure-Pad-Embedded Treadmill Yields Time-Dependent Errors in Estimating Ground Reaction Force during Walking
title A Pressure-Pad-Embedded Treadmill Yields Time-Dependent Errors in Estimating Ground Reaction Force during Walking
title_full A Pressure-Pad-Embedded Treadmill Yields Time-Dependent Errors in Estimating Ground Reaction Force during Walking
title_fullStr A Pressure-Pad-Embedded Treadmill Yields Time-Dependent Errors in Estimating Ground Reaction Force during Walking
title_full_unstemmed A Pressure-Pad-Embedded Treadmill Yields Time-Dependent Errors in Estimating Ground Reaction Force during Walking
title_short A Pressure-Pad-Embedded Treadmill Yields Time-Dependent Errors in Estimating Ground Reaction Force during Walking
title_sort pressure-pad-embedded treadmill yields time-dependent errors in estimating ground reaction force during walking
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8401449/
https://www.ncbi.nlm.nih.gov/pubmed/34450953
http://dx.doi.org/10.3390/s21165511
work_keys_str_mv AT pathakprabhat apressurepadembeddedtreadmillyieldstimedependenterrorsinestimatinggroundreactionforceduringwalking
AT ahnjooeun apressurepadembeddedtreadmillyieldstimedependenterrorsinestimatinggroundreactionforceduringwalking
AT pathakprabhat pressurepadembeddedtreadmillyieldstimedependenterrorsinestimatinggroundreactionforceduringwalking
AT ahnjooeun pressurepadembeddedtreadmillyieldstimedependenterrorsinestimatinggroundreactionforceduringwalking