Cargando…

Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater

Accurate and precise application of ion-selective electrodes (ISEs) in the quantification of environmental pollutants is a strenuous task. In this work, the electrochemical response of alendronate sodium trihydrate (ALN) was evaluated by the fabrication of two sensitive and delicate membrane electro...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdel-Gawad, Sherif A., Afzal, Obaid, Arab, Hany H., Alabbas, Alhumaidi B., Alqarni, Abdulmalik M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8401776/
https://www.ncbi.nlm.nih.gov/pubmed/34443681
http://dx.doi.org/10.3390/molecules26165093
_version_ 1783745631404163072
author Abdel-Gawad, Sherif A.
Afzal, Obaid
Arab, Hany H.
Alabbas, Alhumaidi B.
Alqarni, Abdulmalik M.
author_facet Abdel-Gawad, Sherif A.
Afzal, Obaid
Arab, Hany H.
Alabbas, Alhumaidi B.
Alqarni, Abdulmalik M.
author_sort Abdel-Gawad, Sherif A.
collection PubMed
description Accurate and precise application of ion-selective electrodes (ISEs) in the quantification of environmental pollutants is a strenuous task. In this work, the electrochemical response of alendronate sodium trihydrate (ALN) was evaluated by the fabrication of two sensitive and delicate membrane electrodes, viz. polyvinyl chloride (PVC) and glassy carbon (GC) electrodes. A linear response was obtained at concentrations from 1 × 10(−5) to 1 × 10(−2) M for both electrodes. A Nernstian slope of 29 mV/decade over a pH range of 8–11 for the PVC and GC membrane electrodes was obtained. All assay settings were carefully adjusted to obtain the best electrochemical response. The proposed technique was effectively applied for the quantification of ALN in pure form and wastewater samples, acquired from manufacturing industries. The proposed electrodes were effectively used for the determination of ALN in real wastewater samples without any prior treatment. The current findings guarantee the applicability of the fabricated ISEs for the environmental monitoring of ALN.
format Online
Article
Text
id pubmed-8401776
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84017762021-08-29 Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater Abdel-Gawad, Sherif A. Afzal, Obaid Arab, Hany H. Alabbas, Alhumaidi B. Alqarni, Abdulmalik M. Molecules Article Accurate and precise application of ion-selective electrodes (ISEs) in the quantification of environmental pollutants is a strenuous task. In this work, the electrochemical response of alendronate sodium trihydrate (ALN) was evaluated by the fabrication of two sensitive and delicate membrane electrodes, viz. polyvinyl chloride (PVC) and glassy carbon (GC) electrodes. A linear response was obtained at concentrations from 1 × 10(−5) to 1 × 10(−2) M for both electrodes. A Nernstian slope of 29 mV/decade over a pH range of 8–11 for the PVC and GC membrane electrodes was obtained. All assay settings were carefully adjusted to obtain the best electrochemical response. The proposed technique was effectively applied for the quantification of ALN in pure form and wastewater samples, acquired from manufacturing industries. The proposed electrodes were effectively used for the determination of ALN in real wastewater samples without any prior treatment. The current findings guarantee the applicability of the fabricated ISEs for the environmental monitoring of ALN. MDPI 2021-08-22 /pmc/articles/PMC8401776/ /pubmed/34443681 http://dx.doi.org/10.3390/molecules26165093 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Abdel-Gawad, Sherif A.
Afzal, Obaid
Arab, Hany H.
Alabbas, Alhumaidi B.
Alqarni, Abdulmalik M.
Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater
title Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater
title_full Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater
title_fullStr Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater
title_full_unstemmed Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater
title_short Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater
title_sort fabrication of membrane sensitive electrodes for the validated electrochemical quantification of anti-osteoporotic drug residues in pharmaceutical industrial wastewater
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8401776/
https://www.ncbi.nlm.nih.gov/pubmed/34443681
http://dx.doi.org/10.3390/molecules26165093
work_keys_str_mv AT abdelgawadsherifa fabricationofmembranesensitiveelectrodesforthevalidatedelectrochemicalquantificationofantiosteoporoticdrugresiduesinpharmaceuticalindustrialwastewater
AT afzalobaid fabricationofmembranesensitiveelectrodesforthevalidatedelectrochemicalquantificationofantiosteoporoticdrugresiduesinpharmaceuticalindustrialwastewater
AT arabhanyh fabricationofmembranesensitiveelectrodesforthevalidatedelectrochemicalquantificationofantiosteoporoticdrugresiduesinpharmaceuticalindustrialwastewater
AT alabbasalhumaidib fabricationofmembranesensitiveelectrodesforthevalidatedelectrochemicalquantificationofantiosteoporoticdrugresiduesinpharmaceuticalindustrialwastewater
AT alqarniabdulmalikm fabricationofmembranesensitiveelectrodesforthevalidatedelectrochemicalquantificationofantiosteoporoticdrugresiduesinpharmaceuticalindustrialwastewater