Cargando…
Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater
Accurate and precise application of ion-selective electrodes (ISEs) in the quantification of environmental pollutants is a strenuous task. In this work, the electrochemical response of alendronate sodium trihydrate (ALN) was evaluated by the fabrication of two sensitive and delicate membrane electro...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8401776/ https://www.ncbi.nlm.nih.gov/pubmed/34443681 http://dx.doi.org/10.3390/molecules26165093 |
_version_ | 1783745631404163072 |
---|---|
author | Abdel-Gawad, Sherif A. Afzal, Obaid Arab, Hany H. Alabbas, Alhumaidi B. Alqarni, Abdulmalik M. |
author_facet | Abdel-Gawad, Sherif A. Afzal, Obaid Arab, Hany H. Alabbas, Alhumaidi B. Alqarni, Abdulmalik M. |
author_sort | Abdel-Gawad, Sherif A. |
collection | PubMed |
description | Accurate and precise application of ion-selective electrodes (ISEs) in the quantification of environmental pollutants is a strenuous task. In this work, the electrochemical response of alendronate sodium trihydrate (ALN) was evaluated by the fabrication of two sensitive and delicate membrane electrodes, viz. polyvinyl chloride (PVC) and glassy carbon (GC) electrodes. A linear response was obtained at concentrations from 1 × 10(−5) to 1 × 10(−2) M for both electrodes. A Nernstian slope of 29 mV/decade over a pH range of 8–11 for the PVC and GC membrane electrodes was obtained. All assay settings were carefully adjusted to obtain the best electrochemical response. The proposed technique was effectively applied for the quantification of ALN in pure form and wastewater samples, acquired from manufacturing industries. The proposed electrodes were effectively used for the determination of ALN in real wastewater samples without any prior treatment. The current findings guarantee the applicability of the fabricated ISEs for the environmental monitoring of ALN. |
format | Online Article Text |
id | pubmed-8401776 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84017762021-08-29 Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater Abdel-Gawad, Sherif A. Afzal, Obaid Arab, Hany H. Alabbas, Alhumaidi B. Alqarni, Abdulmalik M. Molecules Article Accurate and precise application of ion-selective electrodes (ISEs) in the quantification of environmental pollutants is a strenuous task. In this work, the electrochemical response of alendronate sodium trihydrate (ALN) was evaluated by the fabrication of two sensitive and delicate membrane electrodes, viz. polyvinyl chloride (PVC) and glassy carbon (GC) electrodes. A linear response was obtained at concentrations from 1 × 10(−5) to 1 × 10(−2) M for both electrodes. A Nernstian slope of 29 mV/decade over a pH range of 8–11 for the PVC and GC membrane electrodes was obtained. All assay settings were carefully adjusted to obtain the best electrochemical response. The proposed technique was effectively applied for the quantification of ALN in pure form and wastewater samples, acquired from manufacturing industries. The proposed electrodes were effectively used for the determination of ALN in real wastewater samples without any prior treatment. The current findings guarantee the applicability of the fabricated ISEs for the environmental monitoring of ALN. MDPI 2021-08-22 /pmc/articles/PMC8401776/ /pubmed/34443681 http://dx.doi.org/10.3390/molecules26165093 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Abdel-Gawad, Sherif A. Afzal, Obaid Arab, Hany H. Alabbas, Alhumaidi B. Alqarni, Abdulmalik M. Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater |
title | Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater |
title_full | Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater |
title_fullStr | Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater |
title_full_unstemmed | Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater |
title_short | Fabrication of Membrane Sensitive Electrodes for the Validated Electrochemical Quantification of Anti-Osteoporotic Drug Residues in Pharmaceutical Industrial Wastewater |
title_sort | fabrication of membrane sensitive electrodes for the validated electrochemical quantification of anti-osteoporotic drug residues in pharmaceutical industrial wastewater |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8401776/ https://www.ncbi.nlm.nih.gov/pubmed/34443681 http://dx.doi.org/10.3390/molecules26165093 |
work_keys_str_mv | AT abdelgawadsherifa fabricationofmembranesensitiveelectrodesforthevalidatedelectrochemicalquantificationofantiosteoporoticdrugresiduesinpharmaceuticalindustrialwastewater AT afzalobaid fabricationofmembranesensitiveelectrodesforthevalidatedelectrochemicalquantificationofantiosteoporoticdrugresiduesinpharmaceuticalindustrialwastewater AT arabhanyh fabricationofmembranesensitiveelectrodesforthevalidatedelectrochemicalquantificationofantiosteoporoticdrugresiduesinpharmaceuticalindustrialwastewater AT alabbasalhumaidib fabricationofmembranesensitiveelectrodesforthevalidatedelectrochemicalquantificationofantiosteoporoticdrugresiduesinpharmaceuticalindustrialwastewater AT alqarniabdulmalikm fabricationofmembranesensitiveelectrodesforthevalidatedelectrochemicalquantificationofantiosteoporoticdrugresiduesinpharmaceuticalindustrialwastewater |