Cargando…

Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction

Background: The presence of noise is problematic in the analysis and interpretation of the ECG, especially in ambulatory monitoring. Restricting the analysis to high-quality signal segments only comes with the risk of excluding significant arrhythmia episodes. Therefore, the development of novel ele...

Descripción completa

Detalles Bibliográficos
Autores principales: Halvaei, Hesam, Sörnmo, Leif, Stridh, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8402297/
https://www.ncbi.nlm.nih.gov/pubmed/34450990
http://dx.doi.org/10.3390/s21165548
_version_ 1783745756050489344
author Halvaei, Hesam
Sörnmo, Leif
Stridh, Martin
author_facet Halvaei, Hesam
Sörnmo, Leif
Stridh, Martin
author_sort Halvaei, Hesam
collection PubMed
description Background: The presence of noise is problematic in the analysis and interpretation of the ECG, especially in ambulatory monitoring. Restricting the analysis to high-quality signal segments only comes with the risk of excluding significant arrhythmia episodes. Therefore, the development of novel electrode technology, robust to noise, continues to be warranted. Methods: The signal quality of a novel wet ECG electrode (Piotrode) is assessed and compared to a commercially available, commonly used electrode (Ambu). The assessment involves indices of QRS detection and atrial fibrillation detection performance, as well as signal quality indices (ensemble standard deviation and time–frequency repeatability), computed from ECGs recorded simultaneously from 20 healthy subjects performing everyday activities. Results: The QRS detection performance using the Piotrode was considerably better than when using the Ambu, especially for running but also for lighter activities. The two signal quality indices demonstrated similar trends: the gap in quality became increasingly larger as the subjects became increasingly more active. Conclusions: The novel wet ECG electrode produces signals with less motion artifacts, thereby offering the potential to reduce the review burden, and accordingly the cost, associated with ambulatory monitoring.
format Online
Article
Text
id pubmed-8402297
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84022972021-08-29 Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction Halvaei, Hesam Sörnmo, Leif Stridh, Martin Sensors (Basel) Article Background: The presence of noise is problematic in the analysis and interpretation of the ECG, especially in ambulatory monitoring. Restricting the analysis to high-quality signal segments only comes with the risk of excluding significant arrhythmia episodes. Therefore, the development of novel electrode technology, robust to noise, continues to be warranted. Methods: The signal quality of a novel wet ECG electrode (Piotrode) is assessed and compared to a commercially available, commonly used electrode (Ambu). The assessment involves indices of QRS detection and atrial fibrillation detection performance, as well as signal quality indices (ensemble standard deviation and time–frequency repeatability), computed from ECGs recorded simultaneously from 20 healthy subjects performing everyday activities. Results: The QRS detection performance using the Piotrode was considerably better than when using the Ambu, especially for running but also for lighter activities. The two signal quality indices demonstrated similar trends: the gap in quality became increasingly larger as the subjects became increasingly more active. Conclusions: The novel wet ECG electrode produces signals with less motion artifacts, thereby offering the potential to reduce the review burden, and accordingly the cost, associated with ambulatory monitoring. MDPI 2021-08-18 /pmc/articles/PMC8402297/ /pubmed/34450990 http://dx.doi.org/10.3390/s21165548 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Halvaei, Hesam
Sörnmo, Leif
Stridh, Martin
Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction
title Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction
title_full Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction
title_fullStr Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction
title_full_unstemmed Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction
title_short Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction
title_sort signal quality assessment of a novel ecg electrode for motion artifact reduction
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8402297/
https://www.ncbi.nlm.nih.gov/pubmed/34450990
http://dx.doi.org/10.3390/s21165548
work_keys_str_mv AT halvaeihesam signalqualityassessmentofanovelecgelectrodeformotionartifactreduction
AT sornmoleif signalqualityassessmentofanovelecgelectrodeformotionartifactreduction
AT stridhmartin signalqualityassessmentofanovelecgelectrodeformotionartifactreduction