Cargando…

Effect of Leukoreduction by Pre-Storage Filtration on Coagulation Activity of Canine Plasma Collected for Transfusion

Leukoreduction of blood products is a technique used to prevent leukocyte-induced transfusion reactions and is extensively used in human, but rarely in veterinary patients. The concentration of some coagulation proteins can be affected by the processing steps used for the preparation of leuko-reduce...

Descripción completa

Detalles Bibliográficos
Autores principales: Spada, Eva, Perego, Roberta, Baggiani, Luciana, Proverbio, Daniela
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8402778/
https://www.ncbi.nlm.nih.gov/pubmed/34437479
http://dx.doi.org/10.3390/vetsci8080157
_version_ 1783745872075423744
author Spada, Eva
Perego, Roberta
Baggiani, Luciana
Proverbio, Daniela
author_facet Spada, Eva
Perego, Roberta
Baggiani, Luciana
Proverbio, Daniela
author_sort Spada, Eva
collection PubMed
description Leukoreduction of blood products is a technique used to prevent leukocyte-induced transfusion reactions and is extensively used in human, but rarely in veterinary patients. The concentration of some coagulation proteins can be affected by the processing steps used for the preparation of leuko-reduced plasma units. In this study, we assessed the effect of leukoreduction on coagulation activity of canine plasma collected for transfusion. Ten plasma units, five obtained from non-leuko-reduced (non-LR) whole blood (WB) units and five from leuko-reduced (LR) WB units were evaluated. Prothrombin time (PT), activated partial thromboplastin time (aPTT), coagulation factor activities of factors (F) V, VIII, X, XI, and von Willebrand (vWF), fibrinogen and D-dimers content were assessed at collection (baseline value, D0) and after 7 days of frozen storage at −18 °C (D7). Compared to non-LR plasma units, LR units showed a statistically significant prolonged aPTT and reduced FXI activity. Filtration had no significant effect on the other factors and parameters evaluated. Filtration-dependent changes appear to have no impact on the therapeutic quality of plasma obtained from leuko-reduced whole blood, other than for FXI activity. Further studies on a larger sample size comparing the same unit before and after leukoreduction are needed to confirm these findings.
format Online
Article
Text
id pubmed-8402778
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84027782021-08-29 Effect of Leukoreduction by Pre-Storage Filtration on Coagulation Activity of Canine Plasma Collected for Transfusion Spada, Eva Perego, Roberta Baggiani, Luciana Proverbio, Daniela Vet Sci Article Leukoreduction of blood products is a technique used to prevent leukocyte-induced transfusion reactions and is extensively used in human, but rarely in veterinary patients. The concentration of some coagulation proteins can be affected by the processing steps used for the preparation of leuko-reduced plasma units. In this study, we assessed the effect of leukoreduction on coagulation activity of canine plasma collected for transfusion. Ten plasma units, five obtained from non-leuko-reduced (non-LR) whole blood (WB) units and five from leuko-reduced (LR) WB units were evaluated. Prothrombin time (PT), activated partial thromboplastin time (aPTT), coagulation factor activities of factors (F) V, VIII, X, XI, and von Willebrand (vWF), fibrinogen and D-dimers content were assessed at collection (baseline value, D0) and after 7 days of frozen storage at −18 °C (D7). Compared to non-LR plasma units, LR units showed a statistically significant prolonged aPTT and reduced FXI activity. Filtration had no significant effect on the other factors and parameters evaluated. Filtration-dependent changes appear to have no impact on the therapeutic quality of plasma obtained from leuko-reduced whole blood, other than for FXI activity. Further studies on a larger sample size comparing the same unit before and after leukoreduction are needed to confirm these findings. MDPI 2021-08-04 /pmc/articles/PMC8402778/ /pubmed/34437479 http://dx.doi.org/10.3390/vetsci8080157 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Spada, Eva
Perego, Roberta
Baggiani, Luciana
Proverbio, Daniela
Effect of Leukoreduction by Pre-Storage Filtration on Coagulation Activity of Canine Plasma Collected for Transfusion
title Effect of Leukoreduction by Pre-Storage Filtration on Coagulation Activity of Canine Plasma Collected for Transfusion
title_full Effect of Leukoreduction by Pre-Storage Filtration on Coagulation Activity of Canine Plasma Collected for Transfusion
title_fullStr Effect of Leukoreduction by Pre-Storage Filtration on Coagulation Activity of Canine Plasma Collected for Transfusion
title_full_unstemmed Effect of Leukoreduction by Pre-Storage Filtration on Coagulation Activity of Canine Plasma Collected for Transfusion
title_short Effect of Leukoreduction by Pre-Storage Filtration on Coagulation Activity of Canine Plasma Collected for Transfusion
title_sort effect of leukoreduction by pre-storage filtration on coagulation activity of canine plasma collected for transfusion
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8402778/
https://www.ncbi.nlm.nih.gov/pubmed/34437479
http://dx.doi.org/10.3390/vetsci8080157
work_keys_str_mv AT spadaeva effectofleukoreductionbyprestoragefiltrationoncoagulationactivityofcanineplasmacollectedfortransfusion
AT peregoroberta effectofleukoreductionbyprestoragefiltrationoncoagulationactivityofcanineplasmacollectedfortransfusion
AT baggianiluciana effectofleukoreductionbyprestoragefiltrationoncoagulationactivityofcanineplasmacollectedfortransfusion
AT proverbiodaniela effectofleukoreductionbyprestoragefiltrationoncoagulationactivityofcanineplasmacollectedfortransfusion