Cargando…

Spheroid-on-chip microfluidic technology for the evaluation of the impact of continuous flow on metastatic potential in cancer models in vitro

The majority of cancer deaths are linked to tumor spread, or metastasis, but 3D in vitro metastasis models relevant to the tumor microenvironment (including interstitial fluid flow) remain an area of unmet need. Microfluidics allows us to introduce controlled flow to an in vitro cancer model to bett...

Descripción completa

Detalles Bibliográficos
Autores principales: Collins, Thomas, Pyne, Emily, Christensen, Martin, Iles, Alexander, Pamme, Nicole, Pires, Isabel M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AIP Publishing LLC 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8403013/
https://www.ncbi.nlm.nih.gov/pubmed/34504636
http://dx.doi.org/10.1063/5.0061373
_version_ 1783745927376273408
author Collins, Thomas
Pyne, Emily
Christensen, Martin
Iles, Alexander
Pamme, Nicole
Pires, Isabel M.
author_facet Collins, Thomas
Pyne, Emily
Christensen, Martin
Iles, Alexander
Pamme, Nicole
Pires, Isabel M.
author_sort Collins, Thomas
collection PubMed
description The majority of cancer deaths are linked to tumor spread, or metastasis, but 3D in vitro metastasis models relevant to the tumor microenvironment (including interstitial fluid flow) remain an area of unmet need. Microfluidics allows us to introduce controlled flow to an in vitro cancer model to better understand the relationship between flow and metastasis. Here, we report new hybrid spheroid-on-chip in vitro models for the impact of interstitial fluid flow on cancer spread. We designed a series of reusable glass microfluidic devices to contain one spheroid in a microwell under continuous perfusion culture. Spheroids derived from established cancer cell lines were perfused with complete media at a flow rate relevant to tumor interstitial fluid flow. Spheroid viability and migratory/invasive capabilities were maintained on-chip when compared to off-chip static conditions. Importantly, using flow conditions modeled in vitro, we are the first to report flow-induced secretion of pro-metastatic factors, in this case cytokines vascular endothelial growth factor and interleukin 6. In summary, we have developed a new, streamlined spheroid-on-chip in vitro model that represents a feasible in vitro alternative to conventional murine in vivo metastasis assays, including complex tumor environmental factors, such as interstitial fluid flow, extracellular matrices, and using 3D models to model nutrient and oxygen gradients. Our device, therefore, constitutes a robust alternative to in vivo early-metastasis models for determination of novel metastasis biomarkers as well as evaluation of therapeutically relevant molecular targets not possible in in vivo murine models.
format Online
Article
Text
id pubmed-8403013
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher AIP Publishing LLC
record_format MEDLINE/PubMed
spelling pubmed-84030132021-11-30 Spheroid-on-chip microfluidic technology for the evaluation of the impact of continuous flow on metastatic potential in cancer models in vitro Collins, Thomas Pyne, Emily Christensen, Martin Iles, Alexander Pamme, Nicole Pires, Isabel M. Biomicrofluidics Regular Articles The majority of cancer deaths are linked to tumor spread, or metastasis, but 3D in vitro metastasis models relevant to the tumor microenvironment (including interstitial fluid flow) remain an area of unmet need. Microfluidics allows us to introduce controlled flow to an in vitro cancer model to better understand the relationship between flow and metastasis. Here, we report new hybrid spheroid-on-chip in vitro models for the impact of interstitial fluid flow on cancer spread. We designed a series of reusable glass microfluidic devices to contain one spheroid in a microwell under continuous perfusion culture. Spheroids derived from established cancer cell lines were perfused with complete media at a flow rate relevant to tumor interstitial fluid flow. Spheroid viability and migratory/invasive capabilities were maintained on-chip when compared to off-chip static conditions. Importantly, using flow conditions modeled in vitro, we are the first to report flow-induced secretion of pro-metastatic factors, in this case cytokines vascular endothelial growth factor and interleukin 6. In summary, we have developed a new, streamlined spheroid-on-chip in vitro model that represents a feasible in vitro alternative to conventional murine in vivo metastasis assays, including complex tumor environmental factors, such as interstitial fluid flow, extracellular matrices, and using 3D models to model nutrient and oxygen gradients. Our device, therefore, constitutes a robust alternative to in vivo early-metastasis models for determination of novel metastasis biomarkers as well as evaluation of therapeutically relevant molecular targets not possible in in vivo murine models. AIP Publishing LLC 2021-08-27 /pmc/articles/PMC8403013/ /pubmed/34504636 http://dx.doi.org/10.1063/5.0061373 Text en © 2021 Author(s). https://creativecommons.org/licenses/by/4.0/All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Regular Articles
Collins, Thomas
Pyne, Emily
Christensen, Martin
Iles, Alexander
Pamme, Nicole
Pires, Isabel M.
Spheroid-on-chip microfluidic technology for the evaluation of the impact of continuous flow on metastatic potential in cancer models in vitro
title Spheroid-on-chip microfluidic technology for the evaluation of the impact of continuous flow on metastatic potential in cancer models in vitro
title_full Spheroid-on-chip microfluidic technology for the evaluation of the impact of continuous flow on metastatic potential in cancer models in vitro
title_fullStr Spheroid-on-chip microfluidic technology for the evaluation of the impact of continuous flow on metastatic potential in cancer models in vitro
title_full_unstemmed Spheroid-on-chip microfluidic technology for the evaluation of the impact of continuous flow on metastatic potential in cancer models in vitro
title_short Spheroid-on-chip microfluidic technology for the evaluation of the impact of continuous flow on metastatic potential in cancer models in vitro
title_sort spheroid-on-chip microfluidic technology for the evaluation of the impact of continuous flow on metastatic potential in cancer models in vitro
topic Regular Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8403013/
https://www.ncbi.nlm.nih.gov/pubmed/34504636
http://dx.doi.org/10.1063/5.0061373
work_keys_str_mv AT collinsthomas spheroidonchipmicrofluidictechnologyfortheevaluationoftheimpactofcontinuousflowonmetastaticpotentialincancermodelsinvitro
AT pyneemily spheroidonchipmicrofluidictechnologyfortheevaluationoftheimpactofcontinuousflowonmetastaticpotentialincancermodelsinvitro
AT christensenmartin spheroidonchipmicrofluidictechnologyfortheevaluationoftheimpactofcontinuousflowonmetastaticpotentialincancermodelsinvitro
AT ilesalexander spheroidonchipmicrofluidictechnologyfortheevaluationoftheimpactofcontinuousflowonmetastaticpotentialincancermodelsinvitro
AT pammenicole spheroidonchipmicrofluidictechnologyfortheevaluationoftheimpactofcontinuousflowonmetastaticpotentialincancermodelsinvitro
AT piresisabelm spheroidonchipmicrofluidictechnologyfortheevaluationoftheimpactofcontinuousflowonmetastaticpotentialincancermodelsinvitro