Decreased Opioid Consumption and Durable Pain Relief in Patients Treated with 10 kHz SCS: A Retrospective Analysis of Outcomes from Single-Center

BACKGROUND: Chronic pain is frequently treated with opioid analgesics, but there is limited evidence for efficacy for chronic use of opioids and the drugs pose significant risks to patients’ physical and mental health. Spinal cord stimulation delivered at a frequency of 10,000 Hertz (10 kHz SCS) is...

Descripción completa

Detalles Bibliográficos
Autores principales: Feng, Honghui, Doherty, Patrick, Rotte, Anand
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8403026/
https://www.ncbi.nlm.nih.gov/pubmed/34466027
http://dx.doi.org/10.2147/JPR.S312932
_version_ 1783745930718085120
author Feng, Honghui
Doherty, Patrick
Rotte, Anand
author_facet Feng, Honghui
Doherty, Patrick
Rotte, Anand
author_sort Feng, Honghui
collection PubMed
description BACKGROUND: Chronic pain is frequently treated with opioid analgesics, but there is limited evidence for efficacy for chronic use of opioids and the drugs pose significant risks to patients’ physical and mental health. Spinal cord stimulation delivered at a frequency of 10,000 Hertz (10 kHz SCS) is a minimally invasive therapy with demonstrated efficacy and safety in treating chronic pain that has also been associated with decreased opioid use. OBJECTIVE: To evaluate opioid reduction and pain relief in real-world cohort. STUDY DESIGN: Retrospective review. SETTING: Single center. PATIENTS AND METHODS: Consecutive patients who were implanted with 10 kHz SCS devices from December 1, 2015, to June 30, 2020 for the treatment of chronic pain in the trunk or lower limbs were included. Changes in opioid use following 10 kHz SCS treatment were extracted from electronic medical records, and patient-reported pain relief, improvement in function and sleep were extracted from manufacturer’s database. Responder rate was defined as the proportion of patients with at least 50% pain relief. Anonymised results from descriptive analysis of the data are reported. RESULTS: At last follow-up (median 21.4 months), mean daily opioid dose fell by 48.4 morphine milligram equivalents (MME), and fewer patients used opioids. Mean pain relief in these patients was 57% ± 4%, and responder rate was 68% at last recorded follow-up. Interestingly, pain relief (66%) and responder rate (86%) were higher in patients with 1 year or more. Finally, 50% of patients reported improved sleep, and 73% reported improvement in function at last recorded follow-up after treatment with 10 kHz SCS. CONCLUSION: These results support 10 kHz SCS as a safe and effective treatment of chronic pain in real-world patients with secondary benefits to opioid consumption and measures of patients’ quality of life.
format Online
Article
Text
id pubmed-8403026
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-84030262021-08-30 Decreased Opioid Consumption and Durable Pain Relief in Patients Treated with 10 kHz SCS: A Retrospective Analysis of Outcomes from Single-Center Feng, Honghui Doherty, Patrick Rotte, Anand J Pain Res Original Research BACKGROUND: Chronic pain is frequently treated with opioid analgesics, but there is limited evidence for efficacy for chronic use of opioids and the drugs pose significant risks to patients’ physical and mental health. Spinal cord stimulation delivered at a frequency of 10,000 Hertz (10 kHz SCS) is a minimally invasive therapy with demonstrated efficacy and safety in treating chronic pain that has also been associated with decreased opioid use. OBJECTIVE: To evaluate opioid reduction and pain relief in real-world cohort. STUDY DESIGN: Retrospective review. SETTING: Single center. PATIENTS AND METHODS: Consecutive patients who were implanted with 10 kHz SCS devices from December 1, 2015, to June 30, 2020 for the treatment of chronic pain in the trunk or lower limbs were included. Changes in opioid use following 10 kHz SCS treatment were extracted from electronic medical records, and patient-reported pain relief, improvement in function and sleep were extracted from manufacturer’s database. Responder rate was defined as the proportion of patients with at least 50% pain relief. Anonymised results from descriptive analysis of the data are reported. RESULTS: At last follow-up (median 21.4 months), mean daily opioid dose fell by 48.4 morphine milligram equivalents (MME), and fewer patients used opioids. Mean pain relief in these patients was 57% ± 4%, and responder rate was 68% at last recorded follow-up. Interestingly, pain relief (66%) and responder rate (86%) were higher in patients with 1 year or more. Finally, 50% of patients reported improved sleep, and 73% reported improvement in function at last recorded follow-up after treatment with 10 kHz SCS. CONCLUSION: These results support 10 kHz SCS as a safe and effective treatment of chronic pain in real-world patients with secondary benefits to opioid consumption and measures of patients’ quality of life. Dove 2021-08-24 /pmc/articles/PMC8403026/ /pubmed/34466027 http://dx.doi.org/10.2147/JPR.S312932 Text en © 2021 Feng et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Feng, Honghui
Doherty, Patrick
Rotte, Anand
Decreased Opioid Consumption and Durable Pain Relief in Patients Treated with 10 kHz SCS: A Retrospective Analysis of Outcomes from Single-Center
title Decreased Opioid Consumption and Durable Pain Relief in Patients Treated with 10 kHz SCS: A Retrospective Analysis of Outcomes from Single-Center
title_full Decreased Opioid Consumption and Durable Pain Relief in Patients Treated with 10 kHz SCS: A Retrospective Analysis of Outcomes from Single-Center
title_fullStr Decreased Opioid Consumption and Durable Pain Relief in Patients Treated with 10 kHz SCS: A Retrospective Analysis of Outcomes from Single-Center
title_full_unstemmed Decreased Opioid Consumption and Durable Pain Relief in Patients Treated with 10 kHz SCS: A Retrospective Analysis of Outcomes from Single-Center
title_short Decreased Opioid Consumption and Durable Pain Relief in Patients Treated with 10 kHz SCS: A Retrospective Analysis of Outcomes from Single-Center
title_sort decreased opioid consumption and durable pain relief in patients treated with 10 khz scs: a retrospective analysis of outcomes from single-center
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8403026/
https://www.ncbi.nlm.nih.gov/pubmed/34466027
http://dx.doi.org/10.2147/JPR.S312932
work_keys_str_mv AT fenghonghui decreasedopioidconsumptionanddurablepainreliefinpatientstreatedwith10khzscsaretrospectiveanalysisofoutcomesfromsinglecenter
AT dohertypatrick decreasedopioidconsumptionanddurablepainreliefinpatientstreatedwith10khzscsaretrospectiveanalysisofoutcomesfromsinglecenter
AT rotteanand decreasedopioidconsumptionanddurablepainreliefinpatientstreatedwith10khzscsaretrospectiveanalysisofoutcomesfromsinglecenter