Investigation of possible transmission of a susceptible microorganism through a contaminated duodenoscope; a case report
BACKGROUND: Despite compliance to extensive reprocessing protocols, duodenoscopes have been linked to outbreaks of susceptible and multi-drug resistant organisms (MDRO) due to persistent duodenoscope contamination. Duodenoscope-associated infections (DAIs) based on transmission of susceptible microo...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8403455/ https://www.ncbi.nlm.nih.gov/pubmed/34454611 http://dx.doi.org/10.1186/s13756-021-00996-7 |
Sumario: | BACKGROUND: Despite compliance to extensive reprocessing protocols, duodenoscopes have been linked to outbreaks of susceptible and multi-drug resistant organisms (MDRO) due to persistent duodenoscope contamination. Duodenoscope-associated infections (DAIs) based on transmission of susceptible microorganisms are likely to be underreported due to detection bias. CASE PRESENTATION: We describe the retrospective detection of a DAI case caused by a susceptible microorganism which at the time of clinical infection was not recognized as such. During 2017 and 2018, duodenoscopes were cultured on a daily basis due to research activities. While analyzing this data, it was found that a duodenoscope had been contaminated with Enterobacter cloacae complex over a period of 3 months. We checked whether patients treated with this duodenoscope had developed infections and found one patient with an E. cloacae cholangitis 3 months after the ERCP (Endoscopic retrograde cholangiopancreaticography) procedure. The isolates on the duodenoscope and in the patients’ blood culture were indistinguishable by amplified fragment length polymorphism (AFLP). By classical multi-locus sequence typing (MLST), both strains were of the same (but novel) sequence type. Application of whole genome MLST showed 93 (out of 3757) allelic differences. CONCLUSION: This case report describes a plausible link between a contaminated duodenoscope and a patient infection with E. cloacae. Transmission of susceptible E. cloacae was highly suspected from AFLP and MLST results; by WGS, 93 allelic differences were found which proves closely related strains. This report shows that DAIs by susceptible microorganisms can be easily missed and therefore its true prevalence remains underscored. |
---|