Cargando…
Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details
BACKGROUND: To characterize the diagnostic role of swept source anterior segment optical coherence tomography (SS-ASOCT) in strabismus re-operations with lost surgical details. METHODS: Patients presenting to our outpatient services for strabismus care from February 2020 to March 15th 2021 were syst...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8403674/ https://www.ncbi.nlm.nih.gov/pubmed/34471343 http://dx.doi.org/10.2147/OPTH.S328215 |
_version_ | 1783746036096827392 |
---|---|
author | Pujari, Amar Modaboyina, Sujeeth Das, Deepsekhar Mahajan, Asmita Thangavel, Rajeswari Phuljhele, Swati Saxena, Rohit Sharma, Namrata Sharma, Pradeep |
author_facet | Pujari, Amar Modaboyina, Sujeeth Das, Deepsekhar Mahajan, Asmita Thangavel, Rajeswari Phuljhele, Swati Saxena, Rohit Sharma, Namrata Sharma, Pradeep |
author_sort | Pujari, Amar |
collection | PubMed |
description | BACKGROUND: To characterize the diagnostic role of swept source anterior segment optical coherence tomography (SS-ASOCT) in strabismus re-operations with lost surgical details. METHODS: Patients presenting to our outpatient services for strabismus care from February 2020 to March 15th 2021 were systematically evaluated. Those willing to undergo re-operation were included in the study. A total of 30 patients were identified and out of this a total of 10 eyes of 10 patients with lost surgical details were finally included in the study. Demographic details, preoperative deviation, ocular findings, orthoptic measurements, detailed SS-ASOCT findings, intraoperative measurements, and post-operative outcomes were recorded. RESULTS: The mean age of 10 patients was 23.7±5.75 years. Seven were male and three were female. The mean pre-operative SS-ASOCT measured distance from angle to insertion was 8.90±1.85 mm and the mean intraoperative distance was 9.12±2.14 mm. A mean difference of 0.21±1.31 mm was noted, and this difference was statistically insignificant (paired t test, p = 0.57). In addition, SS-ASOCT unraveled novel signs to differentiate operated eyes from the un-operated eyes, and recessed muscle from the resected muscle. CONCLUSION: In strabismus re-operation with lost surgical details, the pre-operative SS-ASOCT can provide reliable muscle details with respect to its type of surgery and amount surgery. |
format | Online Article Text |
id | pubmed-8403674 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-84036742021-08-31 Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details Pujari, Amar Modaboyina, Sujeeth Das, Deepsekhar Mahajan, Asmita Thangavel, Rajeswari Phuljhele, Swati Saxena, Rohit Sharma, Namrata Sharma, Pradeep Clin Ophthalmol Original Research BACKGROUND: To characterize the diagnostic role of swept source anterior segment optical coherence tomography (SS-ASOCT) in strabismus re-operations with lost surgical details. METHODS: Patients presenting to our outpatient services for strabismus care from February 2020 to March 15th 2021 were systematically evaluated. Those willing to undergo re-operation were included in the study. A total of 30 patients were identified and out of this a total of 10 eyes of 10 patients with lost surgical details were finally included in the study. Demographic details, preoperative deviation, ocular findings, orthoptic measurements, detailed SS-ASOCT findings, intraoperative measurements, and post-operative outcomes were recorded. RESULTS: The mean age of 10 patients was 23.7±5.75 years. Seven were male and three were female. The mean pre-operative SS-ASOCT measured distance from angle to insertion was 8.90±1.85 mm and the mean intraoperative distance was 9.12±2.14 mm. A mean difference of 0.21±1.31 mm was noted, and this difference was statistically insignificant (paired t test, p = 0.57). In addition, SS-ASOCT unraveled novel signs to differentiate operated eyes from the un-operated eyes, and recessed muscle from the resected muscle. CONCLUSION: In strabismus re-operation with lost surgical details, the pre-operative SS-ASOCT can provide reliable muscle details with respect to its type of surgery and amount surgery. Dove 2021-08-25 /pmc/articles/PMC8403674/ /pubmed/34471343 http://dx.doi.org/10.2147/OPTH.S328215 Text en © 2021 Pujari et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Pujari, Amar Modaboyina, Sujeeth Das, Deepsekhar Mahajan, Asmita Thangavel, Rajeswari Phuljhele, Swati Saxena, Rohit Sharma, Namrata Sharma, Pradeep Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details |
title | Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details |
title_full | Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details |
title_fullStr | Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details |
title_full_unstemmed | Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details |
title_short | Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details |
title_sort | clinical role of swept source anterior segment optical coherence tomography in strabismus re-operation with lost surgical details |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8403674/ https://www.ncbi.nlm.nih.gov/pubmed/34471343 http://dx.doi.org/10.2147/OPTH.S328215 |
work_keys_str_mv | AT pujariamar clinicalroleofsweptsourceanteriorsegmentopticalcoherencetomographyinstrabismusreoperationwithlostsurgicaldetails AT modaboyinasujeeth clinicalroleofsweptsourceanteriorsegmentopticalcoherencetomographyinstrabismusreoperationwithlostsurgicaldetails AT dasdeepsekhar clinicalroleofsweptsourceanteriorsegmentopticalcoherencetomographyinstrabismusreoperationwithlostsurgicaldetails AT mahajanasmita clinicalroleofsweptsourceanteriorsegmentopticalcoherencetomographyinstrabismusreoperationwithlostsurgicaldetails AT thangavelrajeswari clinicalroleofsweptsourceanteriorsegmentopticalcoherencetomographyinstrabismusreoperationwithlostsurgicaldetails AT phuljheleswati clinicalroleofsweptsourceanteriorsegmentopticalcoherencetomographyinstrabismusreoperationwithlostsurgicaldetails AT saxenarohit clinicalroleofsweptsourceanteriorsegmentopticalcoherencetomographyinstrabismusreoperationwithlostsurgicaldetails AT sharmanamrata clinicalroleofsweptsourceanteriorsegmentopticalcoherencetomographyinstrabismusreoperationwithlostsurgicaldetails AT sharmapradeep clinicalroleofsweptsourceanteriorsegmentopticalcoherencetomographyinstrabismusreoperationwithlostsurgicaldetails |