Cargando…
Evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners
OBJECTIVE: The objective of this study was to assess the accuracy of physical reproductions of plaster orthodontic study casts fabricated by two different rapid prototyping techniques: Fused Deposition Modeling (FDM) and Digital Light Processing (DLP). MATERIALS AND METHODS: Twenty pairs of pretreat...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8404487/ https://www.ncbi.nlm.nih.gov/pubmed/33258297 http://dx.doi.org/10.1002/cre2.366 |
_version_ | 1783746177996423168 |
---|---|
author | Jaber, Samer T. Hajeer, Mohammad Y. Khattab, Tarek Z. Mahaini, Luai |
author_facet | Jaber, Samer T. Hajeer, Mohammad Y. Khattab, Tarek Z. Mahaini, Luai |
author_sort | Jaber, Samer T. |
collection | PubMed |
description | OBJECTIVE: The objective of this study was to assess the accuracy of physical reproductions of plaster orthodontic study casts fabricated by two different rapid prototyping techniques: Fused Deposition Modeling (FDM) and Digital Light Processing (DLP). MATERIALS AND METHODS: Twenty pairs of pretreatment plaster models were prepared from randomly selected patients at the Orthodontic Department, University of Damascus Dental School. Twenty‐one reference points were placed on plaster models, followed by scanning and printing of these models using FDM and DLP techniques. Forty measurements were made on these models using a digital caliper. Paired t tests were used to detect significant differences in the measurements between the 3D printed replicas and the original plaster models (Gold Standard). Alpha level was adjusted due to the multiplicity of the tests. RESULTS: The intraclass correlation coefficients for all the comparisons made between the 3D replicas and the gold standard models were greater than 0.80 with ICCs ranging from 0.802 to 0.990 and from 0.853 to 0.990 for the FDM and DLP techniques, respectively. This indicated an excellent agreement. No statistically significant differences could be detected between the 3D‐printed models and their corresponding plaster models. The overall mean difference was −0.11 mm and 0.00 ranging from −0.49 to 0.17 mm and from −0.42 to 0.50 mm, for the FDM and DLP techniques, respectively. CONCLUSION: The accuracy of the 3D models produced by the DLP and FDM techniques was acceptable. However, for the fabrication of clear aligners, the optimum fit of the produced plates in the patients' mouths is not completely guaranteed. |
format | Online Article Text |
id | pubmed-8404487 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-84044872021-09-03 Evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners Jaber, Samer T. Hajeer, Mohammad Y. Khattab, Tarek Z. Mahaini, Luai Clin Exp Dent Res Original Articles OBJECTIVE: The objective of this study was to assess the accuracy of physical reproductions of plaster orthodontic study casts fabricated by two different rapid prototyping techniques: Fused Deposition Modeling (FDM) and Digital Light Processing (DLP). MATERIALS AND METHODS: Twenty pairs of pretreatment plaster models were prepared from randomly selected patients at the Orthodontic Department, University of Damascus Dental School. Twenty‐one reference points were placed on plaster models, followed by scanning and printing of these models using FDM and DLP techniques. Forty measurements were made on these models using a digital caliper. Paired t tests were used to detect significant differences in the measurements between the 3D printed replicas and the original plaster models (Gold Standard). Alpha level was adjusted due to the multiplicity of the tests. RESULTS: The intraclass correlation coefficients for all the comparisons made between the 3D replicas and the gold standard models were greater than 0.80 with ICCs ranging from 0.802 to 0.990 and from 0.853 to 0.990 for the FDM and DLP techniques, respectively. This indicated an excellent agreement. No statistically significant differences could be detected between the 3D‐printed models and their corresponding plaster models. The overall mean difference was −0.11 mm and 0.00 ranging from −0.49 to 0.17 mm and from −0.42 to 0.50 mm, for the FDM and DLP techniques, respectively. CONCLUSION: The accuracy of the 3D models produced by the DLP and FDM techniques was acceptable. However, for the fabrication of clear aligners, the optimum fit of the produced plates in the patients' mouths is not completely guaranteed. John Wiley and Sons Inc. 2020-11-30 /pmc/articles/PMC8404487/ /pubmed/33258297 http://dx.doi.org/10.1002/cre2.366 Text en © 2020 The Authors. Clinical and Experimental Dental Research published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Jaber, Samer T. Hajeer, Mohammad Y. Khattab, Tarek Z. Mahaini, Luai Evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners |
title | Evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners |
title_full | Evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners |
title_fullStr | Evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners |
title_full_unstemmed | Evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners |
title_short | Evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners |
title_sort | evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8404487/ https://www.ncbi.nlm.nih.gov/pubmed/33258297 http://dx.doi.org/10.1002/cre2.366 |
work_keys_str_mv | AT jabersamert evaluationofthefuseddepositionmodelingandthedigitallightprocessingtechniquesintermsofdimensionalaccuracyofprintingdentalmodelsusedforthefabricationofclearaligners AT hajeermohammady evaluationofthefuseddepositionmodelingandthedigitallightprocessingtechniquesintermsofdimensionalaccuracyofprintingdentalmodelsusedforthefabricationofclearaligners AT khattabtarekz evaluationofthefuseddepositionmodelingandthedigitallightprocessingtechniquesintermsofdimensionalaccuracyofprintingdentalmodelsusedforthefabricationofclearaligners AT mahainiluai evaluationofthefuseddepositionmodelingandthedigitallightprocessingtechniquesintermsofdimensionalaccuracyofprintingdentalmodelsusedforthefabricationofclearaligners |