Preoperative mitral annulus size – Can we get it right?
OBJECTIVE: We looked for a correlation between the surgically measured mitral valve size and the cardiac dimensions (left ventricle internal diameter, left atrial size, aorta size, and body surface area) measured by preoperative and intraoperative echocardiography. We also assessed to see if we coul...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8404588/ https://www.ncbi.nlm.nih.gov/pubmed/34269261 http://dx.doi.org/10.4103/aca.ACA_91_20 |
_version_ | 1783746196470235136 |
---|---|
author | Panicker, Varghese T. Sreekantan, Renjith Lokanath, Nagananda |
author_facet | Panicker, Varghese T. Sreekantan, Renjith Lokanath, Nagananda |
author_sort | Panicker, Varghese T. |
collection | PubMed |
description | OBJECTIVE: We looked for a correlation between the surgically measured mitral valve size and the cardiac dimensions (left ventricle internal diameter, left atrial size, aorta size, and body surface area) measured by preoperative and intraoperative echocardiography. We also assessed to see if we could predict the mitral prosthesis size based on the correlation data obtained. METHODS: The hospital records of 180 patients who underwent mitral valve replacement (MVR) with TTK Chitra valve between January 2008 and December 2012 at our hospital, were studied. The correlation between surgically measured mitral annulus size to left ventricular internal diameter systolic (LVIDS) and diastolic (LVIDD), left atrial size (linear measurement), and aorta size on echocardiography and body surface area was calculated using Pearson correlation coefficient. Mean LVIDS was calculated for each valve prosthesis size separately and the correlation was studied. RESULTS: The correlation between mitral valve prosthesis size and left ventricular internal diameter (systolic) showed a Pearson coefficient of 3.3 with significance at the level 0.01. Mitral valve size and left atrial size showed a correlation coefficient of 2.7 with significance at the level 0.01. The correlation coefficient for mitral valve size with left ventricular internal diameter diastolic, aorta and body surface area were 2.5, 1.9, and 1.8, respectively. There was a gradual increase in the mean LVIDS with increase in the prosthetic valve size. Box plot and scatter plot showed linear correlation between valve size and mean LVIDS. |
format | Online Article Text |
id | pubmed-8404588 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-84045882021-09-07 Preoperative mitral annulus size – Can we get it right? Panicker, Varghese T. Sreekantan, Renjith Lokanath, Nagananda Ann Card Anaesth Original Article OBJECTIVE: We looked for a correlation between the surgically measured mitral valve size and the cardiac dimensions (left ventricle internal diameter, left atrial size, aorta size, and body surface area) measured by preoperative and intraoperative echocardiography. We also assessed to see if we could predict the mitral prosthesis size based on the correlation data obtained. METHODS: The hospital records of 180 patients who underwent mitral valve replacement (MVR) with TTK Chitra valve between January 2008 and December 2012 at our hospital, were studied. The correlation between surgically measured mitral annulus size to left ventricular internal diameter systolic (LVIDS) and diastolic (LVIDD), left atrial size (linear measurement), and aorta size on echocardiography and body surface area was calculated using Pearson correlation coefficient. Mean LVIDS was calculated for each valve prosthesis size separately and the correlation was studied. RESULTS: The correlation between mitral valve prosthesis size and left ventricular internal diameter (systolic) showed a Pearson coefficient of 3.3 with significance at the level 0.01. Mitral valve size and left atrial size showed a correlation coefficient of 2.7 with significance at the level 0.01. The correlation coefficient for mitral valve size with left ventricular internal diameter diastolic, aorta and body surface area were 2.5, 1.9, and 1.8, respectively. There was a gradual increase in the mean LVIDS with increase in the prosthetic valve size. Box plot and scatter plot showed linear correlation between valve size and mean LVIDS. Wolters Kluwer - Medknow 2021 2021-07-09 /pmc/articles/PMC8404588/ /pubmed/34269261 http://dx.doi.org/10.4103/aca.ACA_91_20 Text en Copyright: © 2021 Annals of Cardiac Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Panicker, Varghese T. Sreekantan, Renjith Lokanath, Nagananda Preoperative mitral annulus size – Can we get it right? |
title | Preoperative mitral annulus size – Can we get it right? |
title_full | Preoperative mitral annulus size – Can we get it right? |
title_fullStr | Preoperative mitral annulus size – Can we get it right? |
title_full_unstemmed | Preoperative mitral annulus size – Can we get it right? |
title_short | Preoperative mitral annulus size – Can we get it right? |
title_sort | preoperative mitral annulus size – can we get it right? |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8404588/ https://www.ncbi.nlm.nih.gov/pubmed/34269261 http://dx.doi.org/10.4103/aca.ACA_91_20 |
work_keys_str_mv | AT panickervargheset preoperativemitralannulussizecanwegetitright AT sreekantanrenjith preoperativemitralannulussizecanwegetitright AT lokanathnagananda preoperativemitralannulussizecanwegetitright |