Cargando…

The validity of using one force platform to quantify whole-body forces, velocities, and power during a plyometric push-up

BACKGROUND: Previous studies have typically measured velocity and power parameters during the push-up, either using one or two force platforms. The purpose of the study was to compare the force, velocity, and power parameters between the one-force-platform method and the two-force-platform method du...

Descripción completa

Detalles Bibliográficos
Autores principales: Sha, Zhanxin, Dai, Boyi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8406610/
https://www.ncbi.nlm.nih.gov/pubmed/34462003
http://dx.doi.org/10.1186/s13102-021-00330-z
Descripción
Sumario:BACKGROUND: Previous studies have typically measured velocity and power parameters during the push-up, either using one or two force platforms. The purpose of the study was to compare the force, velocity, and power parameters between the one-force-platform method and the two-force-platform method during plyometric push-ups. METHODS: Thirty-four physically active young adults participated in the study to perform the plyometric push-up. For the two-force-platform calculation method, the forces applied to the feet and hands were both measured. For the one-force-platform calculation method, the forces applied to the feet were assumed to be constant, while the forces applied to hands were measured by one force platform. Whole-body linear velocities were calculated based on the impulse and momentum theorem. Whole-body power was calculated as the product of the whole-body forces and velocities. RESULTS: The one-force-platform method overestimated the whole-body velocities and power compared with the two-force-platform method (1.39 ± 0.37 m/s vs. 0.90 ± 0.23 m/s, Cohen’s d = 1.59, p < 0.05; 1.63 ± 0.47 W/body weight vs. 1.03 ± 0.29 W/body weight, Cohen’s d = 1.49, p < 0.05). These differences were caused by the decreased forces applied to the feet compared to the initial value throughout most of the push-up phase. Large to perfect correlations (r = 0.55 – 0.99) were found for most variables between the two-force-platform and one-force-platform methods. Previous findings of push-up velocities and power using the two-force-platform and one-force-platform methods should be compared with caution. While the two-force-platform method is recommended, linear regression equations may be used to predict velocities and power parameters obtained from one force platform. CONCLUSIONS: For those professionals who need to accurately quantify kinetic variables during the plyometric push-up, the two-force-platform method should be considered.