A novel specimen shape for measurement of linear strain fields by means of digital image correlation
Strains on the surface of engineering structures or biological tissues are non-homogeneous. These strain fields can be captured by means of Digital Image Correlation (DIC). However, DIC strain field measurements are prone to noise and filtering of these fields influences measured strain gradients. T...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8410939/ https://www.ncbi.nlm.nih.gov/pubmed/34471200 http://dx.doi.org/10.1038/s41598-021-97085-x |
_version_ | 1783747199454150656 |
---|---|
author | Amraish, Nedaa Reisinger, Andreas Pahr, Dieter |
author_facet | Amraish, Nedaa Reisinger, Andreas Pahr, Dieter |
author_sort | Amraish, Nedaa |
collection | PubMed |
description | Strains on the surface of engineering structures or biological tissues are non-homogeneous. These strain fields can be captured by means of Digital Image Correlation (DIC). However, DIC strain field measurements are prone to noise and filtering of these fields influences measured strain gradients. This study aims to design a novel tensile test specimen showing two linear gradients, to measure full-field linear strain measurements on the surface of test specimens, and to investigate the accuracy of DIC strain measurements globally (full-field) and locally (strain gauges’ positions), with and without filtering of the DIC strain fields. Three materials were employed for this study: aluminium, polymer, and bovine bone. Normalized strain gradients were introduced that are load independent and evaluated at two local positions showing 3.6 and 6.9% strain change per mm. Such levels are typically found in human bones. At these two positions, two strain gauges were applied to check the experimental strain magnitudes. A third strain gauge was applied to measure the strain in a neutral position showing no gradient. The accuracy of the DIC field measurement was evaluated at two deformation stages (at [Formula: see text] 500 and 1750 μstrain) using the root mean square error (RMSE). The RMSE over the two linear strain fields was less than 500 μstrain for both deformation stages and all materials. Gaussian low-pass filter (LPF) reduced the DIC noise between 25% and 64% on average. As well, filtering improved the accuracy of the local normalized strain gradients measurements with relative difference less than 20% and 12% for the high- and low-gradient, respectively. In summary, a novel specimen shape and methodological approach are presented which are useful for evaluating and improving the accuracy of the DIC measurement where non-homogeneous strain fields are expected such as on bone tissue due to their hierarchical structure. |
format | Online Article Text |
id | pubmed-8410939 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-84109392021-09-03 A novel specimen shape for measurement of linear strain fields by means of digital image correlation Amraish, Nedaa Reisinger, Andreas Pahr, Dieter Sci Rep Article Strains on the surface of engineering structures or biological tissues are non-homogeneous. These strain fields can be captured by means of Digital Image Correlation (DIC). However, DIC strain field measurements are prone to noise and filtering of these fields influences measured strain gradients. This study aims to design a novel tensile test specimen showing two linear gradients, to measure full-field linear strain measurements on the surface of test specimens, and to investigate the accuracy of DIC strain measurements globally (full-field) and locally (strain gauges’ positions), with and without filtering of the DIC strain fields. Three materials were employed for this study: aluminium, polymer, and bovine bone. Normalized strain gradients were introduced that are load independent and evaluated at two local positions showing 3.6 and 6.9% strain change per mm. Such levels are typically found in human bones. At these two positions, two strain gauges were applied to check the experimental strain magnitudes. A third strain gauge was applied to measure the strain in a neutral position showing no gradient. The accuracy of the DIC field measurement was evaluated at two deformation stages (at [Formula: see text] 500 and 1750 μstrain) using the root mean square error (RMSE). The RMSE over the two linear strain fields was less than 500 μstrain for both deformation stages and all materials. Gaussian low-pass filter (LPF) reduced the DIC noise between 25% and 64% on average. As well, filtering improved the accuracy of the local normalized strain gradients measurements with relative difference less than 20% and 12% for the high- and low-gradient, respectively. In summary, a novel specimen shape and methodological approach are presented which are useful for evaluating and improving the accuracy of the DIC measurement where non-homogeneous strain fields are expected such as on bone tissue due to their hierarchical structure. Nature Publishing Group UK 2021-09-01 /pmc/articles/PMC8410939/ /pubmed/34471200 http://dx.doi.org/10.1038/s41598-021-97085-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Amraish, Nedaa Reisinger, Andreas Pahr, Dieter A novel specimen shape for measurement of linear strain fields by means of digital image correlation |
title | A novel specimen shape for measurement of linear strain fields by means of digital image correlation |
title_full | A novel specimen shape for measurement of linear strain fields by means of digital image correlation |
title_fullStr | A novel specimen shape for measurement of linear strain fields by means of digital image correlation |
title_full_unstemmed | A novel specimen shape for measurement of linear strain fields by means of digital image correlation |
title_short | A novel specimen shape for measurement of linear strain fields by means of digital image correlation |
title_sort | novel specimen shape for measurement of linear strain fields by means of digital image correlation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8410939/ https://www.ncbi.nlm.nih.gov/pubmed/34471200 http://dx.doi.org/10.1038/s41598-021-97085-x |
work_keys_str_mv | AT amraishnedaa anovelspecimenshapeformeasurementoflinearstrainfieldsbymeansofdigitalimagecorrelation AT reisingerandreas anovelspecimenshapeformeasurementoflinearstrainfieldsbymeansofdigitalimagecorrelation AT pahrdieter anovelspecimenshapeformeasurementoflinearstrainfieldsbymeansofdigitalimagecorrelation AT amraishnedaa novelspecimenshapeformeasurementoflinearstrainfieldsbymeansofdigitalimagecorrelation AT reisingerandreas novelspecimenshapeformeasurementoflinearstrainfieldsbymeansofdigitalimagecorrelation AT pahrdieter novelspecimenshapeformeasurementoflinearstrainfieldsbymeansofdigitalimagecorrelation |