Cargando…

Development and Validation of an Automated Algorithm to Detect Atrial Fibrillation Within Stored Intensive Care Unit Continuous Electrocardiographic Data: Observational Study

BACKGROUND: Atrial fibrillation (AF) is the most common arrhythmia during critical illness, representing a sepsis-defining cardiac dysfunction associated with adverse outcomes. Large burdens of premature beats and noisy signal during sepsis may pose unique challenges to automated AF detection. OBJEC...

Descripción completa

Detalles Bibliográficos
Autores principales: Walkey, Allan J, Bashar, Syed K, Hossain, Md Billal, Ding, Eric, Albuquerque, Daniella, Winter, Michael, Chon, Ki H, McManus, David D
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8411425/
https://www.ncbi.nlm.nih.gov/pubmed/33587041
http://dx.doi.org/10.2196/18840
_version_ 1783747294451990528
author Walkey, Allan J
Bashar, Syed K
Hossain, Md Billal
Ding, Eric
Albuquerque, Daniella
Winter, Michael
Chon, Ki H
McManus, David D
author_facet Walkey, Allan J
Bashar, Syed K
Hossain, Md Billal
Ding, Eric
Albuquerque, Daniella
Winter, Michael
Chon, Ki H
McManus, David D
author_sort Walkey, Allan J
collection PubMed
description BACKGROUND: Atrial fibrillation (AF) is the most common arrhythmia during critical illness, representing a sepsis-defining cardiac dysfunction associated with adverse outcomes. Large burdens of premature beats and noisy signal during sepsis may pose unique challenges to automated AF detection. OBJECTIVE: The objective of this study is to develop and validate an automated algorithm to accurately identify AF within electronic health care data among critically ill patients with sepsis. METHODS: This is a retrospective cohort study of patients hospitalized with sepsis identified from Medical Information Mart for Intensive Care (MIMIC III) electronic health data with linked electrocardiographic (ECG) telemetry waveforms. Within 3 separate cohorts of 50 patients, we iteratively developed and validated an automated algorithm that identifies ECG signals, removes noise, and identifies irregular rhythm and premature beats in order to identify AF. We compared the automated algorithm to current methods of AF identification in large databases, including ICD-9 (International Classification of Diseases, 9th edition) codes and hourly nurse annotation of heart rhythm. Methods of AF identification were tested against gold-standard manual ECG review. RESULTS: AF detection algorithms that did not differentiate AF from premature atrial and ventricular beats performed modestly, with 76% (95% CI 61%-87%) accuracy. Performance improved (P=.02) with the addition of premature beat detection (validation set accuracy: 94% [95% CI 83%-99%]). Median time between automated and manual detection of AF onset was 30 minutes (25th-75th percentile 0-208 minutes). The accuracy of ICD-9 codes (68%; P=.002 vs automated algorithm) and nurse charting (80%; P=.02 vs algorithm) was lower than that of the automated algorithm. CONCLUSIONS: An automated algorithm using telemetry ECG data can feasibly and accurately detect AF among critically ill patients with sepsis, and represents an improvement in AF detection within large databases.
format Online
Article
Text
id pubmed-8411425
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-84114252021-09-02 Development and Validation of an Automated Algorithm to Detect Atrial Fibrillation Within Stored Intensive Care Unit Continuous Electrocardiographic Data: Observational Study Walkey, Allan J Bashar, Syed K Hossain, Md Billal Ding, Eric Albuquerque, Daniella Winter, Michael Chon, Ki H McManus, David D JMIR Cardio Original Paper BACKGROUND: Atrial fibrillation (AF) is the most common arrhythmia during critical illness, representing a sepsis-defining cardiac dysfunction associated with adverse outcomes. Large burdens of premature beats and noisy signal during sepsis may pose unique challenges to automated AF detection. OBJECTIVE: The objective of this study is to develop and validate an automated algorithm to accurately identify AF within electronic health care data among critically ill patients with sepsis. METHODS: This is a retrospective cohort study of patients hospitalized with sepsis identified from Medical Information Mart for Intensive Care (MIMIC III) electronic health data with linked electrocardiographic (ECG) telemetry waveforms. Within 3 separate cohorts of 50 patients, we iteratively developed and validated an automated algorithm that identifies ECG signals, removes noise, and identifies irregular rhythm and premature beats in order to identify AF. We compared the automated algorithm to current methods of AF identification in large databases, including ICD-9 (International Classification of Diseases, 9th edition) codes and hourly nurse annotation of heart rhythm. Methods of AF identification were tested against gold-standard manual ECG review. RESULTS: AF detection algorithms that did not differentiate AF from premature atrial and ventricular beats performed modestly, with 76% (95% CI 61%-87%) accuracy. Performance improved (P=.02) with the addition of premature beat detection (validation set accuracy: 94% [95% CI 83%-99%]). Median time between automated and manual detection of AF onset was 30 minutes (25th-75th percentile 0-208 minutes). The accuracy of ICD-9 codes (68%; P=.002 vs automated algorithm) and nurse charting (80%; P=.02 vs algorithm) was lower than that of the automated algorithm. CONCLUSIONS: An automated algorithm using telemetry ECG data can feasibly and accurately detect AF among critically ill patients with sepsis, and represents an improvement in AF detection within large databases. JMIR Publications 2021-02-15 /pmc/articles/PMC8411425/ /pubmed/33587041 http://dx.doi.org/10.2196/18840 Text en ©Allan J Walkey, Syed K Bashar, Md Billal Hossain, Eric Ding, Daniella Albuquerque, Michael Winter, Ki H Chon, David D McManus. Originally published in JMIR Cardio (http://cardio.jmir.org), 15.02.2021. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Cardio, is properly cited. The complete bibliographic information, a link to the original publication on http://cardio.jmir.org, as well as this copyright and license information must be included.
spellingShingle Original Paper
Walkey, Allan J
Bashar, Syed K
Hossain, Md Billal
Ding, Eric
Albuquerque, Daniella
Winter, Michael
Chon, Ki H
McManus, David D
Development and Validation of an Automated Algorithm to Detect Atrial Fibrillation Within Stored Intensive Care Unit Continuous Electrocardiographic Data: Observational Study
title Development and Validation of an Automated Algorithm to Detect Atrial Fibrillation Within Stored Intensive Care Unit Continuous Electrocardiographic Data: Observational Study
title_full Development and Validation of an Automated Algorithm to Detect Atrial Fibrillation Within Stored Intensive Care Unit Continuous Electrocardiographic Data: Observational Study
title_fullStr Development and Validation of an Automated Algorithm to Detect Atrial Fibrillation Within Stored Intensive Care Unit Continuous Electrocardiographic Data: Observational Study
title_full_unstemmed Development and Validation of an Automated Algorithm to Detect Atrial Fibrillation Within Stored Intensive Care Unit Continuous Electrocardiographic Data: Observational Study
title_short Development and Validation of an Automated Algorithm to Detect Atrial Fibrillation Within Stored Intensive Care Unit Continuous Electrocardiographic Data: Observational Study
title_sort development and validation of an automated algorithm to detect atrial fibrillation within stored intensive care unit continuous electrocardiographic data: observational study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8411425/
https://www.ncbi.nlm.nih.gov/pubmed/33587041
http://dx.doi.org/10.2196/18840
work_keys_str_mv AT walkeyallanj developmentandvalidationofanautomatedalgorithmtodetectatrialfibrillationwithinstoredintensivecareunitcontinuouselectrocardiographicdataobservationalstudy
AT basharsyedk developmentandvalidationofanautomatedalgorithmtodetectatrialfibrillationwithinstoredintensivecareunitcontinuouselectrocardiographicdataobservationalstudy
AT hossainmdbillal developmentandvalidationofanautomatedalgorithmtodetectatrialfibrillationwithinstoredintensivecareunitcontinuouselectrocardiographicdataobservationalstudy
AT dingeric developmentandvalidationofanautomatedalgorithmtodetectatrialfibrillationwithinstoredintensivecareunitcontinuouselectrocardiographicdataobservationalstudy
AT albuquerquedaniella developmentandvalidationofanautomatedalgorithmtodetectatrialfibrillationwithinstoredintensivecareunitcontinuouselectrocardiographicdataobservationalstudy
AT wintermichael developmentandvalidationofanautomatedalgorithmtodetectatrialfibrillationwithinstoredintensivecareunitcontinuouselectrocardiographicdataobservationalstudy
AT chonkih developmentandvalidationofanautomatedalgorithmtodetectatrialfibrillationwithinstoredintensivecareunitcontinuouselectrocardiographicdataobservationalstudy
AT mcmanusdavidd developmentandvalidationofanautomatedalgorithmtodetectatrialfibrillationwithinstoredintensivecareunitcontinuouselectrocardiographicdataobservationalstudy