Cargando…

Implantation of an Innovative Intracardiac Microcomputer System for Web-Based Real-Time Monitoring of Heart Failure: Usability and Patients’ Attitudes

BACKGROUND: Heart failure (HF) management guided by the measurement of intracardiac and pulmonary pressure values obtained through innovative permanent intracardiac microsensors has been recently proposed as a valid strategy to individualize treatment and anticipate hemodynamic destabilization. Thes...

Descripción completa

Detalles Bibliográficos
Autores principales: D´Ancona, Giuseppe, Murero, Monica, Feickert, Sebastian, Kaplan, Hilmi, Öner, Alper, Ortak, Jasmin, Ince, Hueseyin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8411428/
https://www.ncbi.nlm.nih.gov/pubmed/33881400
http://dx.doi.org/10.2196/21055
_version_ 1783747295141953536
author D´Ancona, Giuseppe
Murero, Monica
Feickert, Sebastian
Kaplan, Hilmi
Öner, Alper
Ortak, Jasmin
Ince, Hueseyin
author_facet D´Ancona, Giuseppe
Murero, Monica
Feickert, Sebastian
Kaplan, Hilmi
Öner, Alper
Ortak, Jasmin
Ince, Hueseyin
author_sort D´Ancona, Giuseppe
collection PubMed
description BACKGROUND: Heart failure (HF) management guided by the measurement of intracardiac and pulmonary pressure values obtained through innovative permanent intracardiac microsensors has been recently proposed as a valid strategy to individualize treatment and anticipate hemodynamic destabilization. These sensors have potential to reduce patient hospitalization rates and optimize quality of life. OBJECTIVE: The aim of this study was to evaluate the usability and patients’ attitudes toward a new permanent intracardiac device implanted to remotely monitor left intra-atrial pressures (V-LAP, Vectorious Medical Technologies, Tel Aviv, Israel) in patients with chronic HF. METHODS: The V-LAP system is a miniaturized sensor implanted percutaneously across the interatrial septum. The system communicates wirelessly with a “companion device” (a wearable belt) that is placed on the patient’s chest at the time of acquisition/transmission of left heart pressure measurements. At first follow-up after implantation, the patients and health care providers were asked to fill out a questionnaire on the usability of the system, ease in performing the various required tasks (data acquisition and transmission), and overall satisfaction. Replies to the questions were mainly given using a 5-point Likert scale (1: very poor, 2: poor, 3: average, 4: good, 5: excellent). Further patient follow-ups were performed at 3, 6, and 12 months. RESULTS: Use and acceptance of the first 14 patients receiving the V-LAP technology worldwide and related health care providers have been analyzed to date. No periprocedural morbidity/mortality was observed. Before discharge, a tailored educational session was performed after device implantation with the patients and their health care providers. At the first follow-up, the mean score for overall comfort in technology use was 3.7 (SD 1.2) with 93% (13/14) of patients succeeding in applying and operating the system independently. For health care providers, the mean score for overall ease and comfort in use of the technology was 4.2 (SD 0.8). No significant differences were found between the patients’ and health care providers’ replies to the questionnaires. There was a general trend for higher scores in patients’ usability reports at later follow-ups, in which the score related to overall comfort with using the technology increased from 3.0 (SD 1.4) to 4.0 (SD 0.7) (P=.40) and comfort with wearing and adjusting the measuring thoracic belt increased from 2.8 (SD 1.0) to 4.2 (SD 0.4) (P=.02). CONCLUSIONS: Despite the gravity of their HF pathology and the complexity of their comorbid profile, patients are comfortable in using the V-LAP technology and, in the majority of cases, they can correctly and consistently acquire and transmit hemodynamic data. Although the overall patient/care provider satisfaction with the V-LAP system seems to be acceptable, improvements can be achieved after ameliorating the design of the measuring tools. TRIAL REGISTRATION: ClincalTrials.gov NCT03775161; https://clinicaltrials.gov/ct2/show/NCT03775161
format Online
Article
Text
id pubmed-8411428
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-84114282021-09-02 Implantation of an Innovative Intracardiac Microcomputer System for Web-Based Real-Time Monitoring of Heart Failure: Usability and Patients’ Attitudes D´Ancona, Giuseppe Murero, Monica Feickert, Sebastian Kaplan, Hilmi Öner, Alper Ortak, Jasmin Ince, Hueseyin JMIR Cardio Original Paper BACKGROUND: Heart failure (HF) management guided by the measurement of intracardiac and pulmonary pressure values obtained through innovative permanent intracardiac microsensors has been recently proposed as a valid strategy to individualize treatment and anticipate hemodynamic destabilization. These sensors have potential to reduce patient hospitalization rates and optimize quality of life. OBJECTIVE: The aim of this study was to evaluate the usability and patients’ attitudes toward a new permanent intracardiac device implanted to remotely monitor left intra-atrial pressures (V-LAP, Vectorious Medical Technologies, Tel Aviv, Israel) in patients with chronic HF. METHODS: The V-LAP system is a miniaturized sensor implanted percutaneously across the interatrial septum. The system communicates wirelessly with a “companion device” (a wearable belt) that is placed on the patient’s chest at the time of acquisition/transmission of left heart pressure measurements. At first follow-up after implantation, the patients and health care providers were asked to fill out a questionnaire on the usability of the system, ease in performing the various required tasks (data acquisition and transmission), and overall satisfaction. Replies to the questions were mainly given using a 5-point Likert scale (1: very poor, 2: poor, 3: average, 4: good, 5: excellent). Further patient follow-ups were performed at 3, 6, and 12 months. RESULTS: Use and acceptance of the first 14 patients receiving the V-LAP technology worldwide and related health care providers have been analyzed to date. No periprocedural morbidity/mortality was observed. Before discharge, a tailored educational session was performed after device implantation with the patients and their health care providers. At the first follow-up, the mean score for overall comfort in technology use was 3.7 (SD 1.2) with 93% (13/14) of patients succeeding in applying and operating the system independently. For health care providers, the mean score for overall ease and comfort in use of the technology was 4.2 (SD 0.8). No significant differences were found between the patients’ and health care providers’ replies to the questionnaires. There was a general trend for higher scores in patients’ usability reports at later follow-ups, in which the score related to overall comfort with using the technology increased from 3.0 (SD 1.4) to 4.0 (SD 0.7) (P=.40) and comfort with wearing and adjusting the measuring thoracic belt increased from 2.8 (SD 1.0) to 4.2 (SD 0.4) (P=.02). CONCLUSIONS: Despite the gravity of their HF pathology and the complexity of their comorbid profile, patients are comfortable in using the V-LAP technology and, in the majority of cases, they can correctly and consistently acquire and transmit hemodynamic data. Although the overall patient/care provider satisfaction with the V-LAP system seems to be acceptable, improvements can be achieved after ameliorating the design of the measuring tools. TRIAL REGISTRATION: ClincalTrials.gov NCT03775161; https://clinicaltrials.gov/ct2/show/NCT03775161 JMIR Publications 2021-04-21 /pmc/articles/PMC8411428/ /pubmed/33881400 http://dx.doi.org/10.2196/21055 Text en ©Giuseppe D´Ancona, Monica Murero, Sebastian Feickert, Hilmi Kaplan, Alper Öner, Jasmin Ortak, Hueseyin Ince. Originally published in JMIR Cardio (https://cardio.jmir.org), 21.04.2021. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Cardio, is properly cited. The complete bibliographic information, a link to the original publication on http://cardio.jmir.org, as well as this copyright and license information must be included.
spellingShingle Original Paper
D´Ancona, Giuseppe
Murero, Monica
Feickert, Sebastian
Kaplan, Hilmi
Öner, Alper
Ortak, Jasmin
Ince, Hueseyin
Implantation of an Innovative Intracardiac Microcomputer System for Web-Based Real-Time Monitoring of Heart Failure: Usability and Patients’ Attitudes
title Implantation of an Innovative Intracardiac Microcomputer System for Web-Based Real-Time Monitoring of Heart Failure: Usability and Patients’ Attitudes
title_full Implantation of an Innovative Intracardiac Microcomputer System for Web-Based Real-Time Monitoring of Heart Failure: Usability and Patients’ Attitudes
title_fullStr Implantation of an Innovative Intracardiac Microcomputer System for Web-Based Real-Time Monitoring of Heart Failure: Usability and Patients’ Attitudes
title_full_unstemmed Implantation of an Innovative Intracardiac Microcomputer System for Web-Based Real-Time Monitoring of Heart Failure: Usability and Patients’ Attitudes
title_short Implantation of an Innovative Intracardiac Microcomputer System for Web-Based Real-Time Monitoring of Heart Failure: Usability and Patients’ Attitudes
title_sort implantation of an innovative intracardiac microcomputer system for web-based real-time monitoring of heart failure: usability and patients’ attitudes
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8411428/
https://www.ncbi.nlm.nih.gov/pubmed/33881400
http://dx.doi.org/10.2196/21055
work_keys_str_mv AT danconagiuseppe implantationofaninnovativeintracardiacmicrocomputersystemforwebbasedrealtimemonitoringofheartfailureusabilityandpatientsattitudes
AT mureromonica implantationofaninnovativeintracardiacmicrocomputersystemforwebbasedrealtimemonitoringofheartfailureusabilityandpatientsattitudes
AT feickertsebastian implantationofaninnovativeintracardiacmicrocomputersystemforwebbasedrealtimemonitoringofheartfailureusabilityandpatientsattitudes
AT kaplanhilmi implantationofaninnovativeintracardiacmicrocomputersystemforwebbasedrealtimemonitoringofheartfailureusabilityandpatientsattitudes
AT oneralper implantationofaninnovativeintracardiacmicrocomputersystemforwebbasedrealtimemonitoringofheartfailureusabilityandpatientsattitudes
AT ortakjasmin implantationofaninnovativeintracardiacmicrocomputersystemforwebbasedrealtimemonitoringofheartfailureusabilityandpatientsattitudes
AT incehueseyin implantationofaninnovativeintracardiacmicrocomputersystemforwebbasedrealtimemonitoringofheartfailureusabilityandpatientsattitudes