Cargando…

Comparison of magnitude and summated vector mean of surgically induced astigmatism vector according to incision site after phakic intraocular lens implantation

BACKGROUND: To compare the arithmetic mean (M-SIA) and the summated vector mean of surgically induced astigmatism (SVM-SIA) according to the incision site after phakic intraocular lens (Visian implantable collamer lens (ICL), STAAR Surgical) implantation. METHODS: This study comprised 121 eyes of 12...

Descripción completa

Detalles Bibliográficos
Autores principales: Kamiya, Kazutaka, Ando, Wakako, Takahashi, Masahide, Shoji, Nobuyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8411523/
https://www.ncbi.nlm.nih.gov/pubmed/34470645
http://dx.doi.org/10.1186/s40662-021-00257-z
_version_ 1783747309927923712
author Kamiya, Kazutaka
Ando, Wakako
Takahashi, Masahide
Shoji, Nobuyuki
author_facet Kamiya, Kazutaka
Ando, Wakako
Takahashi, Masahide
Shoji, Nobuyuki
author_sort Kamiya, Kazutaka
collection PubMed
description BACKGROUND: To compare the arithmetic mean (M-SIA) and the summated vector mean of surgically induced astigmatism (SVM-SIA) according to the incision site after phakic intraocular lens (Visian implantable collamer lens (ICL), STAAR Surgical) implantation. METHODS: This study comprised 121 eyes of 121 consecutive patients undergoing ICL surgery through a 3.0-mm temporal or superior clear corneal incision. The magnitude and the axis of corneal astigmatism preoperatively and 3 months postoperatively were measured using an automated keratometer. The M-SIA and the SVM-SIA were determined according to the incision site. RESULTS: The magnitude of corneal astigmatism significantly increased from 1.23 ± 0.59 D preoperatively to 1.46 ± 0.72 D postoperatively in the temporal incision group (Wilcoxon signed-rank test, P < 0.001), but it significantly decreased from 1.09 ± 0.36 D preoperatively to 0.86 ± 0.41 D postoperatively in the superior incision group (P < 0.001). The M-SIA was 0.48 ± 0.30 D, and the SVM-SIA was 0.23 ± 0.52 D at a meridian of 82° in the temporal incision group. The M-SIA was 0.57 ± 0.30 D, and the SVM-SIA was 0.47 ± 0.45 D at a meridian of 1° in the superior incision group. CONCLUSIONS: ICL implantation induces the M-SIA by approximately 0.5 D, but the SVM-SIA decreased to 50% and 80% of the M-SIA in magnitude through temporal and superior incisions, respectively. The direction of the SVM-SIA showed a tendency toward corneal flattening to the incisional site. It should be noted that the M-SIA is somewhat different from the SVM-SIA according to the incision site. Trial registration University Hospital Medical Information Network Clinical Trial Registry (000044269)
format Online
Article
Text
id pubmed-8411523
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-84115232021-09-09 Comparison of magnitude and summated vector mean of surgically induced astigmatism vector according to incision site after phakic intraocular lens implantation Kamiya, Kazutaka Ando, Wakako Takahashi, Masahide Shoji, Nobuyuki Eye Vis (Lond) Research BACKGROUND: To compare the arithmetic mean (M-SIA) and the summated vector mean of surgically induced astigmatism (SVM-SIA) according to the incision site after phakic intraocular lens (Visian implantable collamer lens (ICL), STAAR Surgical) implantation. METHODS: This study comprised 121 eyes of 121 consecutive patients undergoing ICL surgery through a 3.0-mm temporal or superior clear corneal incision. The magnitude and the axis of corneal astigmatism preoperatively and 3 months postoperatively were measured using an automated keratometer. The M-SIA and the SVM-SIA were determined according to the incision site. RESULTS: The magnitude of corneal astigmatism significantly increased from 1.23 ± 0.59 D preoperatively to 1.46 ± 0.72 D postoperatively in the temporal incision group (Wilcoxon signed-rank test, P < 0.001), but it significantly decreased from 1.09 ± 0.36 D preoperatively to 0.86 ± 0.41 D postoperatively in the superior incision group (P < 0.001). The M-SIA was 0.48 ± 0.30 D, and the SVM-SIA was 0.23 ± 0.52 D at a meridian of 82° in the temporal incision group. The M-SIA was 0.57 ± 0.30 D, and the SVM-SIA was 0.47 ± 0.45 D at a meridian of 1° in the superior incision group. CONCLUSIONS: ICL implantation induces the M-SIA by approximately 0.5 D, but the SVM-SIA decreased to 50% and 80% of the M-SIA in magnitude through temporal and superior incisions, respectively. The direction of the SVM-SIA showed a tendency toward corneal flattening to the incisional site. It should be noted that the M-SIA is somewhat different from the SVM-SIA according to the incision site. Trial registration University Hospital Medical Information Network Clinical Trial Registry (000044269) BioMed Central 2021-09-02 /pmc/articles/PMC8411523/ /pubmed/34470645 http://dx.doi.org/10.1186/s40662-021-00257-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Kamiya, Kazutaka
Ando, Wakako
Takahashi, Masahide
Shoji, Nobuyuki
Comparison of magnitude and summated vector mean of surgically induced astigmatism vector according to incision site after phakic intraocular lens implantation
title Comparison of magnitude and summated vector mean of surgically induced astigmatism vector according to incision site after phakic intraocular lens implantation
title_full Comparison of magnitude and summated vector mean of surgically induced astigmatism vector according to incision site after phakic intraocular lens implantation
title_fullStr Comparison of magnitude and summated vector mean of surgically induced astigmatism vector according to incision site after phakic intraocular lens implantation
title_full_unstemmed Comparison of magnitude and summated vector mean of surgically induced astigmatism vector according to incision site after phakic intraocular lens implantation
title_short Comparison of magnitude and summated vector mean of surgically induced astigmatism vector according to incision site after phakic intraocular lens implantation
title_sort comparison of magnitude and summated vector mean of surgically induced astigmatism vector according to incision site after phakic intraocular lens implantation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8411523/
https://www.ncbi.nlm.nih.gov/pubmed/34470645
http://dx.doi.org/10.1186/s40662-021-00257-z
work_keys_str_mv AT kamiyakazutaka comparisonofmagnitudeandsummatedvectormeanofsurgicallyinducedastigmatismvectoraccordingtoincisionsiteafterphakicintraocularlensimplantation
AT andowakako comparisonofmagnitudeandsummatedvectormeanofsurgicallyinducedastigmatismvectoraccordingtoincisionsiteafterphakicintraocularlensimplantation
AT takahashimasahide comparisonofmagnitudeandsummatedvectormeanofsurgicallyinducedastigmatismvectoraccordingtoincisionsiteafterphakicintraocularlensimplantation
AT shojinobuyuki comparisonofmagnitudeandsummatedvectormeanofsurgicallyinducedastigmatismvectoraccordingtoincisionsiteafterphakicintraocularlensimplantation