Cargando…
The Effect of Algorithms on Dose Distribution in Inhomogeneous Phantom: Monaco Treatment Planning System versus Monte Carlo Simulation
BACKGROUND: The aim of this study is to evaluate the dose calculation algorithms commonly used in TPS by using MC simulation in the highly different inhomogeneous region and in the small fields and to provide the following uniquely new information in the study of correction algorithm. MATERIALS AND...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8415246/ https://www.ncbi.nlm.nih.gov/pubmed/34566291 http://dx.doi.org/10.4103/jmp.JMP_21_21 |
_version_ | 1783747929603833856 |
---|---|
author | Tuğrul, Taylan |
author_facet | Tuğrul, Taylan |
author_sort | Tuğrul, Taylan |
collection | PubMed |
description | BACKGROUND: The aim of this study is to evaluate the dose calculation algorithms commonly used in TPS by using MC simulation in the highly different inhomogeneous region and in the small fields and to provide the following uniquely new information in the study of correction algorithm. MATERIALS AND METHODS: We compared the dose distribution obtained by Monaco TPS for small fields. RESULTS: When we examine lung medium, for four different fields, we can see that the algorithms begin to differ. In both the lung and bone environment, the percentage differences decrease as the field size increases. In areas less than or equal to 3x3 cm2, there are serious differences between the algorithms. The CC algorithm calculates a low dose value as the photon passes from the lung environment to water environment. We can also see that this algorithm measures a low dose value in voxel as the photon passes from the water medium to the bone medium. In the transition from the water environment to the bone environment or from the bone environment to the water environment, the results of the CC algorithm are not close to MC simulation. CONCLUSION: The effect of the algorithms used in TPS on dose distribution is very strong, especially in environment with high electron density variation and in applications such as Stereotactic Body Radiotherapy and Intensity Modulated Radiotherapy where small fields are used. |
format | Online Article Text |
id | pubmed-8415246 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-84152462021-09-24 The Effect of Algorithms on Dose Distribution in Inhomogeneous Phantom: Monaco Treatment Planning System versus Monte Carlo Simulation Tuğrul, Taylan J Med Phys Original Article BACKGROUND: The aim of this study is to evaluate the dose calculation algorithms commonly used in TPS by using MC simulation in the highly different inhomogeneous region and in the small fields and to provide the following uniquely new information in the study of correction algorithm. MATERIALS AND METHODS: We compared the dose distribution obtained by Monaco TPS for small fields. RESULTS: When we examine lung medium, for four different fields, we can see that the algorithms begin to differ. In both the lung and bone environment, the percentage differences decrease as the field size increases. In areas less than or equal to 3x3 cm2, there are serious differences between the algorithms. The CC algorithm calculates a low dose value as the photon passes from the lung environment to water environment. We can also see that this algorithm measures a low dose value in voxel as the photon passes from the water medium to the bone medium. In the transition from the water environment to the bone environment or from the bone environment to the water environment, the results of the CC algorithm are not close to MC simulation. CONCLUSION: The effect of the algorithms used in TPS on dose distribution is very strong, especially in environment with high electron density variation and in applications such as Stereotactic Body Radiotherapy and Intensity Modulated Radiotherapy where small fields are used. Wolters Kluwer - Medknow 2021 2021-08-07 /pmc/articles/PMC8415246/ /pubmed/34566291 http://dx.doi.org/10.4103/jmp.JMP_21_21 Text en Copyright: © 2021 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Tuğrul, Taylan The Effect of Algorithms on Dose Distribution in Inhomogeneous Phantom: Monaco Treatment Planning System versus Monte Carlo Simulation |
title | The Effect of Algorithms on Dose Distribution in Inhomogeneous Phantom: Monaco Treatment Planning System versus Monte Carlo Simulation |
title_full | The Effect of Algorithms on Dose Distribution in Inhomogeneous Phantom: Monaco Treatment Planning System versus Monte Carlo Simulation |
title_fullStr | The Effect of Algorithms on Dose Distribution in Inhomogeneous Phantom: Monaco Treatment Planning System versus Monte Carlo Simulation |
title_full_unstemmed | The Effect of Algorithms on Dose Distribution in Inhomogeneous Phantom: Monaco Treatment Planning System versus Monte Carlo Simulation |
title_short | The Effect of Algorithms on Dose Distribution in Inhomogeneous Phantom: Monaco Treatment Planning System versus Monte Carlo Simulation |
title_sort | effect of algorithms on dose distribution in inhomogeneous phantom: monaco treatment planning system versus monte carlo simulation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8415246/ https://www.ncbi.nlm.nih.gov/pubmed/34566291 http://dx.doi.org/10.4103/jmp.JMP_21_21 |
work_keys_str_mv | AT tugrultaylan theeffectofalgorithmsondosedistributionininhomogeneousphantommonacotreatmentplanningsystemversusmontecarlosimulation AT tugrultaylan effectofalgorithmsondosedistributionininhomogeneousphantommonacotreatmentplanningsystemversusmontecarlosimulation |