Cargando…

Comparison of Phase-Gated and Amplitude-Gated Dose Delivery to a Moving Target using Gafchromic EBT3 Film

INTRODUCTION: This study compared phase-gated and amplitude-gated dose deliveries to the moving gross tumor volume (GTV) in lung stereotactic body radiation therapy (SBRT) using Gafchromic External Beam Therapy (EBT3) dosimetry film. MATERIALS AND METHODS: Eighty treatment plans using two techniques...

Descripción completa

Detalles Bibliográficos
Autores principales: Savanović, Milovan, Jaroš, Dražan, Foulquier, Jean Noel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8415247/
https://www.ncbi.nlm.nih.gov/pubmed/34566286
http://dx.doi.org/10.4103/jmp.JMP_81_20
_version_ 1783747929826131968
author Savanović, Milovan
Jaroš, Dražan
Foulquier, Jean Noel
author_facet Savanović, Milovan
Jaroš, Dražan
Foulquier, Jean Noel
author_sort Savanović, Milovan
collection PubMed
description INTRODUCTION: This study compared phase-gated and amplitude-gated dose deliveries to the moving gross tumor volume (GTV) in lung stereotactic body radiation therapy (SBRT) using Gafchromic External Beam Therapy (EBT3) dosimetry film. MATERIALS AND METHODS: Eighty treatment plans using two techniques (40 phase gated and 40 amplitude gated) were delivered using dynamic conformal arc therapy (DCAT). The GTV motion, breathing amplitude, and period were taken from 40 lung SBRT patients who performed regular breathing. These parameters were re-simulated using a modified Varian breathing mini phantom. The dosimetric accuracy of the phase- and amplitude-gated treatment plans was analyzed using Gafchromic EBT3 dosimetry film. The treatment delivery efficacy was analyzed for gantry rotation, number of monitor unit (MU), and target position per triggering window. The time required to deliver the phase- and amplitude-gated treatment techniques was also evaluated. RESULTS: The mean dose (range) per fraction was 16.11 ± 0.91 Gy (13.04–17.50 Gy) versus 16.26 ± 0.83 Gy (13.82–17.99 Gy) (P < 0.0001) for phase- and amplitude-gated delivery. The greater difference in the gamma passing rate was 1.2% ±0.4% in the amplitude-gated compared to the phase gated. The gantry rotation per triggering time (tt) was 2° ±1° (1.2°–3°) versus 5° ±1° (3°–6°) (P < 0.0001) and MU per tt was 10 ± 3 MU (6–13 MU) versus 24 ± 7 MU (12–32 MU) (P < 0.0001), for phase- versus amplitude-gated techniques. A 90 beam interruption in the phase-gated technique impacted the treatment delivery efficacy, increasing the treatment delivery time in the phase gated for 1664 ± 202 s 1353–1942 s) compared to 36 interruptions in the amplitude gated 823 ± 79 s (712–926 s) (P < 0.0001). CONCLUSION: Amplitude-gated DCAT allows for better dosimetric accuracy over phase-gated treatment patients with regular breathing patterns.
format Online
Article
Text
id pubmed-8415247
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-84152472021-09-24 Comparison of Phase-Gated and Amplitude-Gated Dose Delivery to a Moving Target using Gafchromic EBT3 Film Savanović, Milovan Jaroš, Dražan Foulquier, Jean Noel J Med Phys Original Article INTRODUCTION: This study compared phase-gated and amplitude-gated dose deliveries to the moving gross tumor volume (GTV) in lung stereotactic body radiation therapy (SBRT) using Gafchromic External Beam Therapy (EBT3) dosimetry film. MATERIALS AND METHODS: Eighty treatment plans using two techniques (40 phase gated and 40 amplitude gated) were delivered using dynamic conformal arc therapy (DCAT). The GTV motion, breathing amplitude, and period were taken from 40 lung SBRT patients who performed regular breathing. These parameters were re-simulated using a modified Varian breathing mini phantom. The dosimetric accuracy of the phase- and amplitude-gated treatment plans was analyzed using Gafchromic EBT3 dosimetry film. The treatment delivery efficacy was analyzed for gantry rotation, number of monitor unit (MU), and target position per triggering window. The time required to deliver the phase- and amplitude-gated treatment techniques was also evaluated. RESULTS: The mean dose (range) per fraction was 16.11 ± 0.91 Gy (13.04–17.50 Gy) versus 16.26 ± 0.83 Gy (13.82–17.99 Gy) (P < 0.0001) for phase- and amplitude-gated delivery. The greater difference in the gamma passing rate was 1.2% ±0.4% in the amplitude-gated compared to the phase gated. The gantry rotation per triggering time (tt) was 2° ±1° (1.2°–3°) versus 5° ±1° (3°–6°) (P < 0.0001) and MU per tt was 10 ± 3 MU (6–13 MU) versus 24 ± 7 MU (12–32 MU) (P < 0.0001), for phase- versus amplitude-gated techniques. A 90 beam interruption in the phase-gated technique impacted the treatment delivery efficacy, increasing the treatment delivery time in the phase gated for 1664 ± 202 s 1353–1942 s) compared to 36 interruptions in the amplitude gated 823 ± 79 s (712–926 s) (P < 0.0001). CONCLUSION: Amplitude-gated DCAT allows for better dosimetric accuracy over phase-gated treatment patients with regular breathing patterns. Wolters Kluwer - Medknow 2021 2021-08-07 /pmc/articles/PMC8415247/ /pubmed/34566286 http://dx.doi.org/10.4103/jmp.JMP_81_20 Text en Copyright: © 2021 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Savanović, Milovan
Jaroš, Dražan
Foulquier, Jean Noel
Comparison of Phase-Gated and Amplitude-Gated Dose Delivery to a Moving Target using Gafchromic EBT3 Film
title Comparison of Phase-Gated and Amplitude-Gated Dose Delivery to a Moving Target using Gafchromic EBT3 Film
title_full Comparison of Phase-Gated and Amplitude-Gated Dose Delivery to a Moving Target using Gafchromic EBT3 Film
title_fullStr Comparison of Phase-Gated and Amplitude-Gated Dose Delivery to a Moving Target using Gafchromic EBT3 Film
title_full_unstemmed Comparison of Phase-Gated and Amplitude-Gated Dose Delivery to a Moving Target using Gafchromic EBT3 Film
title_short Comparison of Phase-Gated and Amplitude-Gated Dose Delivery to a Moving Target using Gafchromic EBT3 Film
title_sort comparison of phase-gated and amplitude-gated dose delivery to a moving target using gafchromic ebt3 film
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8415247/
https://www.ncbi.nlm.nih.gov/pubmed/34566286
http://dx.doi.org/10.4103/jmp.JMP_81_20
work_keys_str_mv AT savanovicmilovan comparisonofphasegatedandamplitudegateddosedeliverytoamovingtargetusinggafchromicebt3film
AT jarosdrazan comparisonofphasegatedandamplitudegateddosedeliverytoamovingtargetusinggafchromicebt3film
AT foulquierjeannoel comparisonofphasegatedandamplitudegateddosedeliverytoamovingtargetusinggafchromicebt3film