Cargando…

Analysis of aerosol production and aerosol dispersion during otologic surgery

BACKGROUND: As a respiratory disease, the transmission of Coronavirus disease (COVID-19) is mainly caused by small droplets and aerosols. Healthcare personnel are particularly exposed during otologic surgery given the continuity with the nasopharynx, where the viral load is high, and the use of high...

Descripción completa

Detalles Bibliográficos
Autores principales: Gomez Serrano, Manuel, Santiago-Saez, Andres, Moreno Rodriguez, Rosa, Lopez Salcedo, Andrea, Poch Perez-Botija, Adriana, Aragones Sanzen-Baker, William, García Martín, Angel F., García García, Juan Antonio, Iglesias Moreno, Maria Cruz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8415697/
https://www.ncbi.nlm.nih.gov/pubmed/34480224
http://dx.doi.org/10.1007/s00405-021-07059-y
_version_ 1783748021143470080
author Gomez Serrano, Manuel
Santiago-Saez, Andres
Moreno Rodriguez, Rosa
Lopez Salcedo, Andrea
Poch Perez-Botija, Adriana
Aragones Sanzen-Baker, William
García Martín, Angel F.
García García, Juan Antonio
Iglesias Moreno, Maria Cruz
author_facet Gomez Serrano, Manuel
Santiago-Saez, Andres
Moreno Rodriguez, Rosa
Lopez Salcedo, Andrea
Poch Perez-Botija, Adriana
Aragones Sanzen-Baker, William
García Martín, Angel F.
García García, Juan Antonio
Iglesias Moreno, Maria Cruz
author_sort Gomez Serrano, Manuel
collection PubMed
description BACKGROUND: As a respiratory disease, the transmission of Coronavirus disease (COVID-19) is mainly caused by small droplets and aerosols. Healthcare personnel are particularly exposed during otologic surgery given the continuity with the nasopharynx, where the viral load is high, and the use of high-speed instruments. The purpose of the present study is to test a model of droplet dispersion produced in the performance of a drilling procedure on human bone to provide information about its distribution and size of the deposit in similar conditions to those of an operating theatre, to design different preventive measures. MATERIAL AND METHOD: A mastoidectomy and trans-labyrinthine approach were performed on an embalmed human corpse using for irrigation during drilling methylene blue dye in physiological saline solution (pss) at a concentration of 0.324 mg/mL. The distribution of the drops was stablished using semi-absorbent papers of size 52 cm × 42 cm covering the area around the dissection field to a radius of 150 cm and on the corpse at different heights to check vertical dispersion. The collected deposit material was analysed with the microscope at different magnification objectives. RESULTS: Droplets between 2 μm and 2.6 cm were obtained. The visualization of the coloured droplets in the horizontal plane at a magnification of 1.5 was detected at 150 cm from the focus of emission of milling particles. DISCUSSION: According to our study, bone drilling with high speed motors under continuous saline irrigation in a haemorrhagic surgical field increases the amount of aerosols exposing healthcare personnel to additional airbone particles. This risk does not end in the operating rooms as particles smaller than 2 μm can be suspended in the air for hours and could exit the operating theatre due to the use of positive pressure systems. Thus, the use of N95, FFP2, FFP3 or PAPRS should be considered and the development of hood systems to prevent the dispersion of aerosols during these procedures should be considered.
format Online
Article
Text
id pubmed-8415697
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-84156972021-09-07 Analysis of aerosol production and aerosol dispersion during otologic surgery Gomez Serrano, Manuel Santiago-Saez, Andres Moreno Rodriguez, Rosa Lopez Salcedo, Andrea Poch Perez-Botija, Adriana Aragones Sanzen-Baker, William García Martín, Angel F. García García, Juan Antonio Iglesias Moreno, Maria Cruz Eur Arch Otorhinolaryngol Otology BACKGROUND: As a respiratory disease, the transmission of Coronavirus disease (COVID-19) is mainly caused by small droplets and aerosols. Healthcare personnel are particularly exposed during otologic surgery given the continuity with the nasopharynx, where the viral load is high, and the use of high-speed instruments. The purpose of the present study is to test a model of droplet dispersion produced in the performance of a drilling procedure on human bone to provide information about its distribution and size of the deposit in similar conditions to those of an operating theatre, to design different preventive measures. MATERIAL AND METHOD: A mastoidectomy and trans-labyrinthine approach were performed on an embalmed human corpse using for irrigation during drilling methylene blue dye in physiological saline solution (pss) at a concentration of 0.324 mg/mL. The distribution of the drops was stablished using semi-absorbent papers of size 52 cm × 42 cm covering the area around the dissection field to a radius of 150 cm and on the corpse at different heights to check vertical dispersion. The collected deposit material was analysed with the microscope at different magnification objectives. RESULTS: Droplets between 2 μm and 2.6 cm were obtained. The visualization of the coloured droplets in the horizontal plane at a magnification of 1.5 was detected at 150 cm from the focus of emission of milling particles. DISCUSSION: According to our study, bone drilling with high speed motors under continuous saline irrigation in a haemorrhagic surgical field increases the amount of aerosols exposing healthcare personnel to additional airbone particles. This risk does not end in the operating rooms as particles smaller than 2 μm can be suspended in the air for hours and could exit the operating theatre due to the use of positive pressure systems. Thus, the use of N95, FFP2, FFP3 or PAPRS should be considered and the development of hood systems to prevent the dispersion of aerosols during these procedures should be considered. Springer Berlin Heidelberg 2021-09-03 2022 /pmc/articles/PMC8415697/ /pubmed/34480224 http://dx.doi.org/10.1007/s00405-021-07059-y Text en © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2021 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Otology
Gomez Serrano, Manuel
Santiago-Saez, Andres
Moreno Rodriguez, Rosa
Lopez Salcedo, Andrea
Poch Perez-Botija, Adriana
Aragones Sanzen-Baker, William
García Martín, Angel F.
García García, Juan Antonio
Iglesias Moreno, Maria Cruz
Analysis of aerosol production and aerosol dispersion during otologic surgery
title Analysis of aerosol production and aerosol dispersion during otologic surgery
title_full Analysis of aerosol production and aerosol dispersion during otologic surgery
title_fullStr Analysis of aerosol production and aerosol dispersion during otologic surgery
title_full_unstemmed Analysis of aerosol production and aerosol dispersion during otologic surgery
title_short Analysis of aerosol production and aerosol dispersion during otologic surgery
title_sort analysis of aerosol production and aerosol dispersion during otologic surgery
topic Otology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8415697/
https://www.ncbi.nlm.nih.gov/pubmed/34480224
http://dx.doi.org/10.1007/s00405-021-07059-y
work_keys_str_mv AT gomezserranomanuel analysisofaerosolproductionandaerosoldispersionduringotologicsurgery
AT santiagosaezandres analysisofaerosolproductionandaerosoldispersionduringotologicsurgery
AT morenorodriguezrosa analysisofaerosolproductionandaerosoldispersionduringotologicsurgery
AT lopezsalcedoandrea analysisofaerosolproductionandaerosoldispersionduringotologicsurgery
AT pochperezbotijaadriana analysisofaerosolproductionandaerosoldispersionduringotologicsurgery
AT aragonessanzenbakerwilliam analysisofaerosolproductionandaerosoldispersionduringotologicsurgery
AT garciamartinangelf analysisofaerosolproductionandaerosoldispersionduringotologicsurgery
AT garciagarciajuanantonio analysisofaerosolproductionandaerosoldispersionduringotologicsurgery
AT iglesiasmorenomariacruz analysisofaerosolproductionandaerosoldispersionduringotologicsurgery