Background: Fluocinolone acetonide (FAc) implant represents a long-term strategy for the management of diabetic macular edema (DME). Because of the 3-year duration, the careful monitoring of the intraocular pressure (IOP) is necessary. The main aim of the study was to provide quantitative IOP cutoff...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8416620/ https://www.ncbi.nlm.nih.gov/pubmed/34490313 http://dx.doi.org/10.3389/fmed.2021.725349 |
_version_ | 1783748227022979072 |
---|---|
author | Arrigo, Alessandro Aragona, Emanuela Capone, Luigi Di Biase, Carlo Lattanzio, Rosangela Bandello, Francesco |
author_facet | Arrigo, Alessandro Aragona, Emanuela Capone, Luigi Di Biase, Carlo Lattanzio, Rosangela Bandello, Francesco |
author_sort | Arrigo, Alessandro |
collection | PubMed |
description | Background: Fluocinolone acetonide (FAc) implant represents a long-term strategy for the management of diabetic macular edema (DME). Because of the 3-year duration, the careful monitoring of the intraocular pressure (IOP) is necessary. The main aim of the study was to provide quantitative IOP cutoffs associated with the onset of IOP increases. Methods: The study was retrospectively conducted with 2-year of follow-up. We separately considered eyes with good IOP control (Group 1), eyes requiring IOP-lowering medications (Group 2) and eyes undergoing IOP-lowering surgery (Group 3). The statistical analysis assessed Delta% IOP changes over the 2-year follow-up. ROC analysis was performed to detect significant cutoffs associated with Group 2 and Group 3. IOP changes occurring after a previously administered dexamethasone (DEX) implant were also evaluated. Results: We included 48 eyes (48 patients), stratified as follows: Group 1 (25/48; 52%), Group 2 (19/48; 40%) and Group 3 (4/48; 8%). ROC analysis performed on IOP values detected 2-months later DEX implant showed a mean Delta IOP increase>24% significantly associated with IOP-lowering medications after FAc implant, whereas a mean Delta IOP increase>35% was significantly associated with IOP-lowering surgery after FAc implant. With respect to IOP changes occurred after FAc implant, our ROC analysis showed a mean Delta IOP increase>8% significantly associated with IOP-lowering medications, whereas a mean Delta IOP increase>15% was significantly associated with IOP-lowering surgery. DEX-related IOP changes showed 52% sensitivity and 100% specificity of FAc-related IOP increases. Conclusions: IOP changes provides clinically relevant cutoffs associated with the onset of FAc-related IOP increases. |
format | Online Article Text |
id | pubmed-8416620 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-84166202021-09-05 Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant Arrigo, Alessandro Aragona, Emanuela Capone, Luigi Di Biase, Carlo Lattanzio, Rosangela Bandello, Francesco Front Med (Lausanne) Medicine Background: Fluocinolone acetonide (FAc) implant represents a long-term strategy for the management of diabetic macular edema (DME). Because of the 3-year duration, the careful monitoring of the intraocular pressure (IOP) is necessary. The main aim of the study was to provide quantitative IOP cutoffs associated with the onset of IOP increases. Methods: The study was retrospectively conducted with 2-year of follow-up. We separately considered eyes with good IOP control (Group 1), eyes requiring IOP-lowering medications (Group 2) and eyes undergoing IOP-lowering surgery (Group 3). The statistical analysis assessed Delta% IOP changes over the 2-year follow-up. ROC analysis was performed to detect significant cutoffs associated with Group 2 and Group 3. IOP changes occurring after a previously administered dexamethasone (DEX) implant were also evaluated. Results: We included 48 eyes (48 patients), stratified as follows: Group 1 (25/48; 52%), Group 2 (19/48; 40%) and Group 3 (4/48; 8%). ROC analysis performed on IOP values detected 2-months later DEX implant showed a mean Delta IOP increase>24% significantly associated with IOP-lowering medications after FAc implant, whereas a mean Delta IOP increase>35% was significantly associated with IOP-lowering surgery after FAc implant. With respect to IOP changes occurred after FAc implant, our ROC analysis showed a mean Delta IOP increase>8% significantly associated with IOP-lowering medications, whereas a mean Delta IOP increase>15% was significantly associated with IOP-lowering surgery. DEX-related IOP changes showed 52% sensitivity and 100% specificity of FAc-related IOP increases. Conclusions: IOP changes provides clinically relevant cutoffs associated with the onset of FAc-related IOP increases. Frontiers Media S.A. 2021-08-19 /pmc/articles/PMC8416620/ /pubmed/34490313 http://dx.doi.org/10.3389/fmed.2021.725349 Text en Copyright © 2021 Arrigo, Aragona, Capone, Di Biase, Lattanzio and Bandello. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Arrigo, Alessandro Aragona, Emanuela Capone, Luigi Di Biase, Carlo Lattanzio, Rosangela Bandello, Francesco Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant |
title | Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant |
title_full | Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant |
title_fullStr | Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant |
title_full_unstemmed | Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant |
title_short | Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant |
title_sort | intraocular pressure changes are predictive of ocular hypertension onset after fluocinolone acetonide implant: significant cutoffs and the role of previous dex implant |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8416620/ https://www.ncbi.nlm.nih.gov/pubmed/34490313 http://dx.doi.org/10.3389/fmed.2021.725349 |
work_keys_str_mv | AT arrigoalessandro intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant AT aragonaemanuela intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant AT caponeluigi intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant AT dibiasecarlo intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant AT lattanziorosangela intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant AT bandellofrancesco intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant |