Cargando…

Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant

Background: Fluocinolone acetonide (FAc) implant represents a long-term strategy for the management of diabetic macular edema (DME). Because of the 3-year duration, the careful monitoring of the intraocular pressure (IOP) is necessary. The main aim of the study was to provide quantitative IOP cutoff...

Descripción completa

Detalles Bibliográficos
Autores principales: Arrigo, Alessandro, Aragona, Emanuela, Capone, Luigi, Di Biase, Carlo, Lattanzio, Rosangela, Bandello, Francesco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8416620/
https://www.ncbi.nlm.nih.gov/pubmed/34490313
http://dx.doi.org/10.3389/fmed.2021.725349
_version_ 1783748227022979072
author Arrigo, Alessandro
Aragona, Emanuela
Capone, Luigi
Di Biase, Carlo
Lattanzio, Rosangela
Bandello, Francesco
author_facet Arrigo, Alessandro
Aragona, Emanuela
Capone, Luigi
Di Biase, Carlo
Lattanzio, Rosangela
Bandello, Francesco
author_sort Arrigo, Alessandro
collection PubMed
description Background: Fluocinolone acetonide (FAc) implant represents a long-term strategy for the management of diabetic macular edema (DME). Because of the 3-year duration, the careful monitoring of the intraocular pressure (IOP) is necessary. The main aim of the study was to provide quantitative IOP cutoffs associated with the onset of IOP increases. Methods: The study was retrospectively conducted with 2-year of follow-up. We separately considered eyes with good IOP control (Group 1), eyes requiring IOP-lowering medications (Group 2) and eyes undergoing IOP-lowering surgery (Group 3). The statistical analysis assessed Delta% IOP changes over the 2-year follow-up. ROC analysis was performed to detect significant cutoffs associated with Group 2 and Group 3. IOP changes occurring after a previously administered dexamethasone (DEX) implant were also evaluated. Results: We included 48 eyes (48 patients), stratified as follows: Group 1 (25/48; 52%), Group 2 (19/48; 40%) and Group 3 (4/48; 8%). ROC analysis performed on IOP values detected 2-months later DEX implant showed a mean Delta IOP increase>24% significantly associated with IOP-lowering medications after FAc implant, whereas a mean Delta IOP increase>35% was significantly associated with IOP-lowering surgery after FAc implant. With respect to IOP changes occurred after FAc implant, our ROC analysis showed a mean Delta IOP increase>8% significantly associated with IOP-lowering medications, whereas a mean Delta IOP increase>15% was significantly associated with IOP-lowering surgery. DEX-related IOP changes showed 52% sensitivity and 100% specificity of FAc-related IOP increases. Conclusions: IOP changes provides clinically relevant cutoffs associated with the onset of FAc-related IOP increases.
format Online
Article
Text
id pubmed-8416620
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-84166202021-09-05 Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant Arrigo, Alessandro Aragona, Emanuela Capone, Luigi Di Biase, Carlo Lattanzio, Rosangela Bandello, Francesco Front Med (Lausanne) Medicine Background: Fluocinolone acetonide (FAc) implant represents a long-term strategy for the management of diabetic macular edema (DME). Because of the 3-year duration, the careful monitoring of the intraocular pressure (IOP) is necessary. The main aim of the study was to provide quantitative IOP cutoffs associated with the onset of IOP increases. Methods: The study was retrospectively conducted with 2-year of follow-up. We separately considered eyes with good IOP control (Group 1), eyes requiring IOP-lowering medications (Group 2) and eyes undergoing IOP-lowering surgery (Group 3). The statistical analysis assessed Delta% IOP changes over the 2-year follow-up. ROC analysis was performed to detect significant cutoffs associated with Group 2 and Group 3. IOP changes occurring after a previously administered dexamethasone (DEX) implant were also evaluated. Results: We included 48 eyes (48 patients), stratified as follows: Group 1 (25/48; 52%), Group 2 (19/48; 40%) and Group 3 (4/48; 8%). ROC analysis performed on IOP values detected 2-months later DEX implant showed a mean Delta IOP increase>24% significantly associated with IOP-lowering medications after FAc implant, whereas a mean Delta IOP increase>35% was significantly associated with IOP-lowering surgery after FAc implant. With respect to IOP changes occurred after FAc implant, our ROC analysis showed a mean Delta IOP increase>8% significantly associated with IOP-lowering medications, whereas a mean Delta IOP increase>15% was significantly associated with IOP-lowering surgery. DEX-related IOP changes showed 52% sensitivity and 100% specificity of FAc-related IOP increases. Conclusions: IOP changes provides clinically relevant cutoffs associated with the onset of FAc-related IOP increases. Frontiers Media S.A. 2021-08-19 /pmc/articles/PMC8416620/ /pubmed/34490313 http://dx.doi.org/10.3389/fmed.2021.725349 Text en Copyright © 2021 Arrigo, Aragona, Capone, Di Biase, Lattanzio and Bandello. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Arrigo, Alessandro
Aragona, Emanuela
Capone, Luigi
Di Biase, Carlo
Lattanzio, Rosangela
Bandello, Francesco
Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant
title Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant
title_full Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant
title_fullStr Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant
title_full_unstemmed Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant
title_short Intraocular Pressure Changes Are Predictive of Ocular Hypertension Onset After Fluocinolone Acetonide Implant: Significant Cutoffs and the Role of Previous DEX Implant
title_sort intraocular pressure changes are predictive of ocular hypertension onset after fluocinolone acetonide implant: significant cutoffs and the role of previous dex implant
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8416620/
https://www.ncbi.nlm.nih.gov/pubmed/34490313
http://dx.doi.org/10.3389/fmed.2021.725349
work_keys_str_mv AT arrigoalessandro intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant
AT aragonaemanuela intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant
AT caponeluigi intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant
AT dibiasecarlo intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant
AT lattanziorosangela intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant
AT bandellofrancesco intraocularpressurechangesarepredictiveofocularhypertensiononsetafterfluocinoloneacetonideimplantsignificantcutoffsandtheroleofpreviousdeximplant