Cargando…

Model-Based Estimation of Iohexol Plasma Clearance for Pragmatic Renal Function Determination in the Renal Transplantation Setting

BACKGROUND: Iohexol plasma clearance-based glomerular filtration rate (GFR) determination provides an accurate method for renal function evaluation. This technique is increasingly advocated for clinical situations that dictate highly accurate renal function assessment, as an alternative to conventio...

Descripción completa

Detalles Bibliográficos
Autores principales: Zwart, Tom C., de Vries, Aiko P. J., Engbers, Aline G. J., Dam, Ruth E., van der Boog, Paul J. M., Swen, Jesse J., Keizer, Ron J., Dalton, R. Neil, Guchelaar, Henk-Jan, de Fijter, Johan W., Moes, Dirk Jan A. R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8417017/
https://www.ncbi.nlm.nih.gov/pubmed/33864239
http://dx.doi.org/10.1007/s40262-021-00998-z
_version_ 1783748299060150272
author Zwart, Tom C.
de Vries, Aiko P. J.
Engbers, Aline G. J.
Dam, Ruth E.
van der Boog, Paul J. M.
Swen, Jesse J.
Keizer, Ron J.
Dalton, R. Neil
Guchelaar, Henk-Jan
de Fijter, Johan W.
Moes, Dirk Jan A. R.
author_facet Zwart, Tom C.
de Vries, Aiko P. J.
Engbers, Aline G. J.
Dam, Ruth E.
van der Boog, Paul J. M.
Swen, Jesse J.
Keizer, Ron J.
Dalton, R. Neil
Guchelaar, Henk-Jan
de Fijter, Johan W.
Moes, Dirk Jan A. R.
author_sort Zwart, Tom C.
collection PubMed
description BACKGROUND: Iohexol plasma clearance-based glomerular filtration rate (GFR) determination provides an accurate method for renal function evaluation. This technique is increasingly advocated for clinical situations that dictate highly accurate renal function assessment, as an alternative to conventional serum creatinine-based methods with limited accuracy or poor feasibility. In the renal transplantation setting, this particularly applies to living renal transplant donor eligibility screening, renal transplant function monitoring and research purposes. The dependency of current iohexol GFR estimation techniques on extensive sampling, however, has limited its clinical application. We developed a population pharmacokinetic model and limited sampling schedules, implemented in the online InsightRX precision dosing platform, to facilitate pragmatic iohexol GFR assessment. METHODS: Iohexol concentrations (n = 587) drawn 5 min to 4 h after administration were available from 67 renal transplant recipients and 41 living renal transplant donor candidates with measured iohexol GFRs of 27–117 mL/min/1.73 m(2). These were split into a model development (n = 72) cohort and an internal validation (n = 36) cohort. External validation was performed with 1040 iohexol concentrations from 268 renal transplant recipients drawn between 5 min and 4 h after administration, and extended iohexol curves up to 24 h from 11 random patients with impaired renal function. Limited sampling schedules based on one to four blood draws within 4 h after iohexol administration were evaluated in terms of bias and imprecision, using the mean relative prediction error and mean absolute relative prediction error. The total deviation index and percentage of limited sampling schedule-based GFR predictions within ± 10% of those of the full model (P(10)) were assessed to aid interpretation. RESULTS: Iohexol pharmacokinetics was best described with a two-compartmental first-order elimination model, allometrically scaled to fat-free mass, with patient type as a covariate on clearance and the central distribution volume. Model validity was confirmed during the internal and external validation. Various limited sampling schedules based on three to four blood draws within 4 h showed excellent predictive performance (mean relative prediction error < ± 0.5%, mean absolute relative prediction error < 3.5%, total deviation index < 5.5%, P(10) > 97%). The best limited sampling schedules based on three to four blood draws within 3 h showed reduced predictive performance (mean relative prediction error < ± 0.75%, mean absolute relative prediction error < 5.5%, total deviation index < 9.5%, P(10) ≥ 85%), but may be considered for their enhanced clinical feasibility when deemed justified. CONCLUSIONS: Our online pharmacometric tool provides an accurate, pragmatic, and ready-to-use technique for measured GFR-based renal function evaluation for clinical situations where conventional methods lack accuracy or show limited feasibility. Additional adaptation and validation of our model and limited sampling schedules for renal transplant recipients with GFRs below 30 mL/min is warranted before considering this technique in these patients. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40262-021-00998-z.
format Online
Article
Text
id pubmed-8417017
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-84170172021-09-22 Model-Based Estimation of Iohexol Plasma Clearance for Pragmatic Renal Function Determination in the Renal Transplantation Setting Zwart, Tom C. de Vries, Aiko P. J. Engbers, Aline G. J. Dam, Ruth E. van der Boog, Paul J. M. Swen, Jesse J. Keizer, Ron J. Dalton, R. Neil Guchelaar, Henk-Jan de Fijter, Johan W. Moes, Dirk Jan A. R. Clin Pharmacokinet Original Research Article BACKGROUND: Iohexol plasma clearance-based glomerular filtration rate (GFR) determination provides an accurate method for renal function evaluation. This technique is increasingly advocated for clinical situations that dictate highly accurate renal function assessment, as an alternative to conventional serum creatinine-based methods with limited accuracy or poor feasibility. In the renal transplantation setting, this particularly applies to living renal transplant donor eligibility screening, renal transplant function monitoring and research purposes. The dependency of current iohexol GFR estimation techniques on extensive sampling, however, has limited its clinical application. We developed a population pharmacokinetic model and limited sampling schedules, implemented in the online InsightRX precision dosing platform, to facilitate pragmatic iohexol GFR assessment. METHODS: Iohexol concentrations (n = 587) drawn 5 min to 4 h after administration were available from 67 renal transplant recipients and 41 living renal transplant donor candidates with measured iohexol GFRs of 27–117 mL/min/1.73 m(2). These were split into a model development (n = 72) cohort and an internal validation (n = 36) cohort. External validation was performed with 1040 iohexol concentrations from 268 renal transplant recipients drawn between 5 min and 4 h after administration, and extended iohexol curves up to 24 h from 11 random patients with impaired renal function. Limited sampling schedules based on one to four blood draws within 4 h after iohexol administration were evaluated in terms of bias and imprecision, using the mean relative prediction error and mean absolute relative prediction error. The total deviation index and percentage of limited sampling schedule-based GFR predictions within ± 10% of those of the full model (P(10)) were assessed to aid interpretation. RESULTS: Iohexol pharmacokinetics was best described with a two-compartmental first-order elimination model, allometrically scaled to fat-free mass, with patient type as a covariate on clearance and the central distribution volume. Model validity was confirmed during the internal and external validation. Various limited sampling schedules based on three to four blood draws within 4 h showed excellent predictive performance (mean relative prediction error < ± 0.5%, mean absolute relative prediction error < 3.5%, total deviation index < 5.5%, P(10) > 97%). The best limited sampling schedules based on three to four blood draws within 3 h showed reduced predictive performance (mean relative prediction error < ± 0.75%, mean absolute relative prediction error < 5.5%, total deviation index < 9.5%, P(10) ≥ 85%), but may be considered for their enhanced clinical feasibility when deemed justified. CONCLUSIONS: Our online pharmacometric tool provides an accurate, pragmatic, and ready-to-use technique for measured GFR-based renal function evaluation for clinical situations where conventional methods lack accuracy or show limited feasibility. Additional adaptation and validation of our model and limited sampling schedules for renal transplant recipients with GFRs below 30 mL/min is warranted before considering this technique in these patients. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40262-021-00998-z. Springer International Publishing 2021-04-17 2021 /pmc/articles/PMC8417017/ /pubmed/33864239 http://dx.doi.org/10.1007/s40262-021-00998-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/Open AccessThis article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Original Research Article
Zwart, Tom C.
de Vries, Aiko P. J.
Engbers, Aline G. J.
Dam, Ruth E.
van der Boog, Paul J. M.
Swen, Jesse J.
Keizer, Ron J.
Dalton, R. Neil
Guchelaar, Henk-Jan
de Fijter, Johan W.
Moes, Dirk Jan A. R.
Model-Based Estimation of Iohexol Plasma Clearance for Pragmatic Renal Function Determination in the Renal Transplantation Setting
title Model-Based Estimation of Iohexol Plasma Clearance for Pragmatic Renal Function Determination in the Renal Transplantation Setting
title_full Model-Based Estimation of Iohexol Plasma Clearance for Pragmatic Renal Function Determination in the Renal Transplantation Setting
title_fullStr Model-Based Estimation of Iohexol Plasma Clearance for Pragmatic Renal Function Determination in the Renal Transplantation Setting
title_full_unstemmed Model-Based Estimation of Iohexol Plasma Clearance for Pragmatic Renal Function Determination in the Renal Transplantation Setting
title_short Model-Based Estimation of Iohexol Plasma Clearance for Pragmatic Renal Function Determination in the Renal Transplantation Setting
title_sort model-based estimation of iohexol plasma clearance for pragmatic renal function determination in the renal transplantation setting
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8417017/
https://www.ncbi.nlm.nih.gov/pubmed/33864239
http://dx.doi.org/10.1007/s40262-021-00998-z
work_keys_str_mv AT zwarttomc modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting
AT devriesaikopj modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting
AT engbersalinegj modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting
AT damruthe modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting
AT vanderboogpauljm modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting
AT swenjessej modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting
AT keizerronj modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting
AT daltonrneil modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting
AT guchelaarhenkjan modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting
AT defijterjohanw modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting
AT moesdirkjanar modelbasedestimationofiohexolplasmaclearanceforpragmaticrenalfunctiondeterminationintherenaltransplantationsetting