Cargando…
ATENA–A Novel Rapidly Manufactured Medical Invasive Ventilator Designed as a Response to the COVID-19 Pandemic: Testing Protocol, Safety, and Performance Validation
Background: The urgent need for mechanical ventilators to support respiratory insufficiency due to SARS-CoV-2 led to a worldwide effort to develop low-cost, easily assembled, and locally manufactured ventilators. The ATENA ventilator project was developed in a community-based approach targeting the...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8418230/ https://www.ncbi.nlm.nih.gov/pubmed/34490282 http://dx.doi.org/10.3389/fmed.2021.614580 |
_version_ | 1783748543507333120 |
---|---|
author | Rebelo, Tiago Neutel, Elizabete Alves, Eurico Castro Barros, Francisco Oliveira, Hélder Machado, Humberto Mendonça, Joana Araújo, João Fortuna Luís, João Pêgo, José M. Silva, José Oliveira, Manuel Sousa, Nuno Figueiredo, Paulo Barata, Pedro Magalhães, Raquel Silva Magalhães, Rui Miguel Gomes, Sara H. |
author_facet | Rebelo, Tiago Neutel, Elizabete Alves, Eurico Castro Barros, Francisco Oliveira, Hélder Machado, Humberto Mendonça, Joana Araújo, João Fortuna Luís, João Pêgo, José M. Silva, José Oliveira, Manuel Sousa, Nuno Figueiredo, Paulo Barata, Pedro Magalhães, Raquel Silva Magalhães, Rui Miguel Gomes, Sara H. |
author_sort | Rebelo, Tiago |
collection | PubMed |
description | Background: The urgent need for mechanical ventilators to support respiratory insufficiency due to SARS-CoV-2 led to a worldwide effort to develop low-cost, easily assembled, and locally manufactured ventilators. The ATENA ventilator project was developed in a community-based approach targeting the development, prototyping, testing, and decentralized manufacturing of a new mechanical ventilator. Objective: This article aims to demonstrate ATENA's adequate performance and safety for clinical use. Material: ATENA is a low-cost ventilator that can be rapidly manufactured, easily assembled, and locally produced anywhere in the world. It was developed following the guidelines and requirements provided by European and International Regulatory Authorities (MHRA, ISO 86201) and National Authorities (INFARMED). The device was thoroughly tested using laboratory lung simulators and animal models. Results: The device meets all the regulatory requirements for pandemic ventilators. Additionally, the pre-clinical experiences demonstrated security and adequate ventilation and oxygenation, in vivo. Conclusion: The ATENA ventilator had a good performance in required tests in laboratory scenarios and pre-clinical studies. In a pandemic context, ATENA is perfectly suited for safely treating patients in need of mechanical ventilation. |
format | Online Article Text |
id | pubmed-8418230 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-84182302021-09-05 ATENA–A Novel Rapidly Manufactured Medical Invasive Ventilator Designed as a Response to the COVID-19 Pandemic: Testing Protocol, Safety, and Performance Validation Rebelo, Tiago Neutel, Elizabete Alves, Eurico Castro Barros, Francisco Oliveira, Hélder Machado, Humberto Mendonça, Joana Araújo, João Fortuna Luís, João Pêgo, José M. Silva, José Oliveira, Manuel Sousa, Nuno Figueiredo, Paulo Barata, Pedro Magalhães, Raquel Silva Magalhães, Rui Miguel Gomes, Sara H. Front Med (Lausanne) Medicine Background: The urgent need for mechanical ventilators to support respiratory insufficiency due to SARS-CoV-2 led to a worldwide effort to develop low-cost, easily assembled, and locally manufactured ventilators. The ATENA ventilator project was developed in a community-based approach targeting the development, prototyping, testing, and decentralized manufacturing of a new mechanical ventilator. Objective: This article aims to demonstrate ATENA's adequate performance and safety for clinical use. Material: ATENA is a low-cost ventilator that can be rapidly manufactured, easily assembled, and locally produced anywhere in the world. It was developed following the guidelines and requirements provided by European and International Regulatory Authorities (MHRA, ISO 86201) and National Authorities (INFARMED). The device was thoroughly tested using laboratory lung simulators and animal models. Results: The device meets all the regulatory requirements for pandemic ventilators. Additionally, the pre-clinical experiences demonstrated security and adequate ventilation and oxygenation, in vivo. Conclusion: The ATENA ventilator had a good performance in required tests in laboratory scenarios and pre-clinical studies. In a pandemic context, ATENA is perfectly suited for safely treating patients in need of mechanical ventilation. Frontiers Media S.A. 2021-08-19 /pmc/articles/PMC8418230/ /pubmed/34490282 http://dx.doi.org/10.3389/fmed.2021.614580 Text en Copyright © 2021 Rebelo, Neutel, Alves, Barros, Oliveira, Machado, Mendonça, Araújo, Luís, Pêgo, Silva, Oliveira, Sousa, Figueiredo, Barata, Magalhães, Magalhães and Gomes. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Rebelo, Tiago Neutel, Elizabete Alves, Eurico Castro Barros, Francisco Oliveira, Hélder Machado, Humberto Mendonça, Joana Araújo, João Fortuna Luís, João Pêgo, José M. Silva, José Oliveira, Manuel Sousa, Nuno Figueiredo, Paulo Barata, Pedro Magalhães, Raquel Silva Magalhães, Rui Miguel Gomes, Sara H. ATENA–A Novel Rapidly Manufactured Medical Invasive Ventilator Designed as a Response to the COVID-19 Pandemic: Testing Protocol, Safety, and Performance Validation |
title | ATENA–A Novel Rapidly Manufactured Medical Invasive Ventilator Designed as a Response to the COVID-19 Pandemic: Testing Protocol, Safety, and Performance Validation |
title_full | ATENA–A Novel Rapidly Manufactured Medical Invasive Ventilator Designed as a Response to the COVID-19 Pandemic: Testing Protocol, Safety, and Performance Validation |
title_fullStr | ATENA–A Novel Rapidly Manufactured Medical Invasive Ventilator Designed as a Response to the COVID-19 Pandemic: Testing Protocol, Safety, and Performance Validation |
title_full_unstemmed | ATENA–A Novel Rapidly Manufactured Medical Invasive Ventilator Designed as a Response to the COVID-19 Pandemic: Testing Protocol, Safety, and Performance Validation |
title_short | ATENA–A Novel Rapidly Manufactured Medical Invasive Ventilator Designed as a Response to the COVID-19 Pandemic: Testing Protocol, Safety, and Performance Validation |
title_sort | atena–a novel rapidly manufactured medical invasive ventilator designed as a response to the covid-19 pandemic: testing protocol, safety, and performance validation |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8418230/ https://www.ncbi.nlm.nih.gov/pubmed/34490282 http://dx.doi.org/10.3389/fmed.2021.614580 |
work_keys_str_mv | AT rebelotiago atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT neutelelizabete atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT alveseuricocastro atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT barrosfrancisco atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT oliveirahelder atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT machadohumberto atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT mendoncajoana atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT araujojoaofortuna atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT luisjoao atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT pegojosem atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT silvajose atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT oliveiramanuel atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT sousanuno atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT figueiredopaulo atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT baratapedro atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT magalhaesraquelsilva atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT magalhaesruimiguel atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation AT gomessarah atenaanovelrapidlymanufacturedmedicalinvasiveventilatordesignedasaresponsetothecovid19pandemictestingprotocolsafetyandperformancevalidation |