Cargando…
The biotin interference within interference suppressed immunoassays
BACKGROUND: Reports of false laboratory findings due to a biotin supplementation have raised concerns about the safety of immunoassays. According to current research, biotin is known to cause interference in immunoassays. Since up to 70% of medical decisions are based on laboratory results and the s...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8418509/ https://www.ncbi.nlm.nih.gov/pubmed/34346119 http://dx.doi.org/10.1002/jcla.23940 |
_version_ | 1783748585215492096 |
---|---|
author | Kabiri, Payam Weiskirchen, Ralf van Helden, Josef |
author_facet | Kabiri, Payam Weiskirchen, Ralf van Helden, Josef |
author_sort | Kabiri, Payam |
collection | PubMed |
description | BACKGROUND: Reports of false laboratory findings due to a biotin supplementation have raised concerns about the safety of immunoassays. According to current research, biotin is known to cause interference in immunoassays. Since up to 70% of medical decisions are based on laboratory results and the significantly increased intake of biotin supplements in the recent years, the reliability of immunoassays is essential. METHODS: To evaluate this reliability two experiments were conducted. In the first experiment 59 interference suppressed immunoassays of the manufacturer Roche Diagnostics were examined regarding their sensitivity to a biotin interference. In the second experiment the pharmacokinetic of biotin was examined by supplementing volunteers with biotin. RESULTS: A combination of the results of both experiments suggests that a biotin interference in laboratory findings is probable. Contrary to the current state of research on sandwich immunoassays, falsely elevated test results occur more frequently than falsely low results. CONCLUSION: The interference suppressed immunoassays have shown in the experiment that they are susceptible to a biotin interference. Therefore, laboratory institutions, medical staff and patients must be aware of the possibility of a biotin interference. As a result, Roche Diagnostics may consider reviewing the interference suppression and their indications of the tests. |
format | Online Article Text |
id | pubmed-8418509 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-84185092021-09-08 The biotin interference within interference suppressed immunoassays Kabiri, Payam Weiskirchen, Ralf van Helden, Josef J Clin Lab Anal Research Articles BACKGROUND: Reports of false laboratory findings due to a biotin supplementation have raised concerns about the safety of immunoassays. According to current research, biotin is known to cause interference in immunoassays. Since up to 70% of medical decisions are based on laboratory results and the significantly increased intake of biotin supplements in the recent years, the reliability of immunoassays is essential. METHODS: To evaluate this reliability two experiments were conducted. In the first experiment 59 interference suppressed immunoassays of the manufacturer Roche Diagnostics were examined regarding their sensitivity to a biotin interference. In the second experiment the pharmacokinetic of biotin was examined by supplementing volunteers with biotin. RESULTS: A combination of the results of both experiments suggests that a biotin interference in laboratory findings is probable. Contrary to the current state of research on sandwich immunoassays, falsely elevated test results occur more frequently than falsely low results. CONCLUSION: The interference suppressed immunoassays have shown in the experiment that they are susceptible to a biotin interference. Therefore, laboratory institutions, medical staff and patients must be aware of the possibility of a biotin interference. As a result, Roche Diagnostics may consider reviewing the interference suppression and their indications of the tests. John Wiley and Sons Inc. 2021-08-04 /pmc/articles/PMC8418509/ /pubmed/34346119 http://dx.doi.org/10.1002/jcla.23940 Text en © 2021 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Research Articles Kabiri, Payam Weiskirchen, Ralf van Helden, Josef The biotin interference within interference suppressed immunoassays |
title | The biotin interference within interference suppressed immunoassays |
title_full | The biotin interference within interference suppressed immunoassays |
title_fullStr | The biotin interference within interference suppressed immunoassays |
title_full_unstemmed | The biotin interference within interference suppressed immunoassays |
title_short | The biotin interference within interference suppressed immunoassays |
title_sort | biotin interference within interference suppressed immunoassays |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8418509/ https://www.ncbi.nlm.nih.gov/pubmed/34346119 http://dx.doi.org/10.1002/jcla.23940 |
work_keys_str_mv | AT kabiripayam thebiotininterferencewithininterferencesuppressedimmunoassays AT weiskirchenralf thebiotininterferencewithininterferencesuppressedimmunoassays AT vanheldenjosef thebiotininterferencewithininterferencesuppressedimmunoassays AT kabiripayam biotininterferencewithininterferencesuppressedimmunoassays AT weiskirchenralf biotininterferencewithininterferencesuppressedimmunoassays AT vanheldenjosef biotininterferencewithininterferencesuppressedimmunoassays |