Cargando…
Simultaneous measurement of 13 circulating vitamin D3 and D2 mono and dihydroxy metabolites using liquid chromatography mass spectrometry
OBJECTIVES: Clinical evaluation of vitamin D status is conventionally performed by measuring serum levels of a single vitamin D metabolite, 25-hydroxyvitamin D predominantly by immunoassay methodology. However, this neglects the complex metabolic pathways involved in vitamin D bioactivity, including...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
De Gruyter
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8419114/ https://www.ncbi.nlm.nih.gov/pubmed/34013677 http://dx.doi.org/10.1515/cclm-2021-0441 |
_version_ | 1783748682922852352 |
---|---|
author | Jenkinson, Carl Desai, Reena Slominski, Andrzej T. Tuckey, Robert C. Hewison, Martin Handelsman, David J. |
author_facet | Jenkinson, Carl Desai, Reena Slominski, Andrzej T. Tuckey, Robert C. Hewison, Martin Handelsman, David J. |
author_sort | Jenkinson, Carl |
collection | PubMed |
description | OBJECTIVES: Clinical evaluation of vitamin D status is conventionally performed by measuring serum levels of a single vitamin D metabolite, 25-hydroxyvitamin D predominantly by immunoassay methodology. However, this neglects the complex metabolic pathways involved in vitamin D bioactivity, including two canonical forms D3 and D2, bioactive 1,25-dihydroxy metabolites and inactive 24-hydroxy and other metabolites. METHODS: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) can measure multiple analytes in a sample during a single run with high sensitivity and reference level specificity. We therefore aimed to develop and validate a LC-MS/MS method to measure simultaneously 13 circulating vitamin D metabolites and apply it to 103 human serum samples. RESULTS: The LC-MS/MS method using a Cookson-type derivatization reagent phenyl-1,2,4-triazoline-3,5-dione (PTAD) quantifies 13 vitamin D metabolites, including mono and dihydroxy-metabolites, as well as CYP11A1-derived D3 and D2 metabolites in a single run. The lower limit of quantitation was 12.5 pg/mL for 1,25(OH)(2)D3 with accuracy verified by analysis of National Institute of Standards and Technology (NIST) 972a standards. Quantification of seven metabolites (25(OH)D3, 25(OH)D2, 3-epi-25(OH)D3, 20(OH)D3, 24,25(OH)(2)D3, 1,25(OH)(2)D3 and 1,20S(OH)(2)D3) was consistently achieved in human serum samples. CONCLUSIONS: This profiling method can provide new insight into circulating vitamin D metabolite pathways forming the basis for improved understanding of the role of vitamin D in health and disease. |
format | Online Article Text |
id | pubmed-8419114 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | De Gruyter |
record_format | MEDLINE/PubMed |
spelling | pubmed-84191142022-07-18 Simultaneous measurement of 13 circulating vitamin D3 and D2 mono and dihydroxy metabolites using liquid chromatography mass spectrometry Jenkinson, Carl Desai, Reena Slominski, Andrzej T. Tuckey, Robert C. Hewison, Martin Handelsman, David J. Clin Chem Lab Med Article OBJECTIVES: Clinical evaluation of vitamin D status is conventionally performed by measuring serum levels of a single vitamin D metabolite, 25-hydroxyvitamin D predominantly by immunoassay methodology. However, this neglects the complex metabolic pathways involved in vitamin D bioactivity, including two canonical forms D3 and D2, bioactive 1,25-dihydroxy metabolites and inactive 24-hydroxy and other metabolites. METHODS: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) can measure multiple analytes in a sample during a single run with high sensitivity and reference level specificity. We therefore aimed to develop and validate a LC-MS/MS method to measure simultaneously 13 circulating vitamin D metabolites and apply it to 103 human serum samples. RESULTS: The LC-MS/MS method using a Cookson-type derivatization reagent phenyl-1,2,4-triazoline-3,5-dione (PTAD) quantifies 13 vitamin D metabolites, including mono and dihydroxy-metabolites, as well as CYP11A1-derived D3 and D2 metabolites in a single run. The lower limit of quantitation was 12.5 pg/mL for 1,25(OH)(2)D3 with accuracy verified by analysis of National Institute of Standards and Technology (NIST) 972a standards. Quantification of seven metabolites (25(OH)D3, 25(OH)D2, 3-epi-25(OH)D3, 20(OH)D3, 24,25(OH)(2)D3, 1,25(OH)(2)D3 and 1,20S(OH)(2)D3) was consistently achieved in human serum samples. CONCLUSIONS: This profiling method can provide new insight into circulating vitamin D metabolite pathways forming the basis for improved understanding of the role of vitamin D in health and disease. De Gruyter 2021-09-27 2021-05-20 /pmc/articles/PMC8419114/ /pubmed/34013677 http://dx.doi.org/10.1515/cclm-2021-0441 Text en © 2021 Carl Jenkinson et al., published by De Gruyter, Berlin/Boston https://creativecommons.org/licenses/by/4.0/This work is licensed under the Creative Commons Attribution 4.0 International License. |
spellingShingle | Article Jenkinson, Carl Desai, Reena Slominski, Andrzej T. Tuckey, Robert C. Hewison, Martin Handelsman, David J. Simultaneous measurement of 13 circulating vitamin D3 and D2 mono and dihydroxy metabolites using liquid chromatography mass spectrometry |
title | Simultaneous measurement of 13 circulating vitamin D3 and D2 mono and dihydroxy metabolites using liquid chromatography mass spectrometry |
title_full | Simultaneous measurement of 13 circulating vitamin D3 and D2 mono and dihydroxy metabolites using liquid chromatography mass spectrometry |
title_fullStr | Simultaneous measurement of 13 circulating vitamin D3 and D2 mono and dihydroxy metabolites using liquid chromatography mass spectrometry |
title_full_unstemmed | Simultaneous measurement of 13 circulating vitamin D3 and D2 mono and dihydroxy metabolites using liquid chromatography mass spectrometry |
title_short | Simultaneous measurement of 13 circulating vitamin D3 and D2 mono and dihydroxy metabolites using liquid chromatography mass spectrometry |
title_sort | simultaneous measurement of 13 circulating vitamin d3 and d2 mono and dihydroxy metabolites using liquid chromatography mass spectrometry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8419114/ https://www.ncbi.nlm.nih.gov/pubmed/34013677 http://dx.doi.org/10.1515/cclm-2021-0441 |
work_keys_str_mv | AT jenkinsoncarl simultaneousmeasurementof13circulatingvitamind3andd2monoanddihydroxymetabolitesusingliquidchromatographymassspectrometry AT desaireena simultaneousmeasurementof13circulatingvitamind3andd2monoanddihydroxymetabolitesusingliquidchromatographymassspectrometry AT slominskiandrzejt simultaneousmeasurementof13circulatingvitamind3andd2monoanddihydroxymetabolitesusingliquidchromatographymassspectrometry AT tuckeyrobertc simultaneousmeasurementof13circulatingvitamind3andd2monoanddihydroxymetabolitesusingliquidchromatographymassspectrometry AT hewisonmartin simultaneousmeasurementof13circulatingvitamind3andd2monoanddihydroxymetabolitesusingliquidchromatographymassspectrometry AT handelsmandavidj simultaneousmeasurementof13circulatingvitamind3andd2monoanddihydroxymetabolitesusingliquidchromatographymassspectrometry |