Extraction of Broken Tibial Interlock Nail with a Retrograde Hooked Guide Wire: A Novel Surgical Technique

INTRODUCTION: Removal of a distal piece of a broken nail often possesses a technical challenge. Several methods have been described in the past to extract a distal piece by using specialized instruments like such as hooks, olive wires, and talwalkar radial square nail etc. It is difficult to extract...

Descripción completa

Detalles Bibliográficos
Autores principales: Garg, Bipul K, Dave, Harshit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8422007/
https://www.ncbi.nlm.nih.gov/pubmed/34557436
http://dx.doi.org/10.13107/jocr.2021.v11.i05.2196
_version_ 1783749197713899520
author Garg, Bipul K
Dave, Harshit
author_facet Garg, Bipul K
Dave, Harshit
author_sort Garg, Bipul K
collection PubMed
description INTRODUCTION: Removal of a distal piece of a broken nail often possesses a technical challenge. Several methods have been described in the past to extract a distal piece by using specialized instruments like such as hooks, olive wires, and talwalkar radial square nail etc. It is difficult to extract a distal piece from a proximal incision site and often fracture or the nonunion site has to be opened. In this article, we describe a novel technique to extract a distal piece of broken intramedullary tibia nail by retrograde manner using a guide wire with a “‘U”’ shaped bend at its distal end to hook the tip of a distal piece of broken nail and help in extraction. CASE REPORT: A 43- year-s old male presented with complain of pain in left leg since 3 months. Patient had sustained left- sided compound Grade 2 tibia shaft fracture in a road traffic accident 4 years back. He was operated with tibia interlock nail followed by skin grafting for wound coverage in a different facility. On clinical examination: There was tenderness around distal tibia, no swelling, no coronal or sagittal plane fracture mobility, and no crepitus or loss of transmitted movements which suggested fracture union clinically. Radiographs confirmed complete union of tibia shaft fracture with hypertrophic nonunion of distal fibula with broken intramedullary nail IMN at the level of proximal most screw hole of distal locking holes with both distal locking screws broken. As fracture was united, we planned for removal of broken nail without opening fracture site. For extraction for distal tibial broken nail part, we used this new Retrograde Hooked Guide Wire technique. CONCLUSION: It is a simple, cost effective, minimally invasive procedure with minimal blood loss and decrease time of surgery that can be used before attempting more invasive extraction methods and hence should be included in standard procedures for extraction.
format Online
Article
Text
id pubmed-8422007
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-84220072021-09-22 Extraction of Broken Tibial Interlock Nail with a Retrograde Hooked Guide Wire: A Novel Surgical Technique Garg, Bipul K Dave, Harshit J Orthop Case Rep Case Report INTRODUCTION: Removal of a distal piece of a broken nail often possesses a technical challenge. Several methods have been described in the past to extract a distal piece by using specialized instruments like such as hooks, olive wires, and talwalkar radial square nail etc. It is difficult to extract a distal piece from a proximal incision site and often fracture or the nonunion site has to be opened. In this article, we describe a novel technique to extract a distal piece of broken intramedullary tibia nail by retrograde manner using a guide wire with a “‘U”’ shaped bend at its distal end to hook the tip of a distal piece of broken nail and help in extraction. CASE REPORT: A 43- year-s old male presented with complain of pain in left leg since 3 months. Patient had sustained left- sided compound Grade 2 tibia shaft fracture in a road traffic accident 4 years back. He was operated with tibia interlock nail followed by skin grafting for wound coverage in a different facility. On clinical examination: There was tenderness around distal tibia, no swelling, no coronal or sagittal plane fracture mobility, and no crepitus or loss of transmitted movements which suggested fracture union clinically. Radiographs confirmed complete union of tibia shaft fracture with hypertrophic nonunion of distal fibula with broken intramedullary nail IMN at the level of proximal most screw hole of distal locking holes with both distal locking screws broken. As fracture was united, we planned for removal of broken nail without opening fracture site. For extraction for distal tibial broken nail part, we used this new Retrograde Hooked Guide Wire technique. CONCLUSION: It is a simple, cost effective, minimally invasive procedure with minimal blood loss and decrease time of surgery that can be used before attempting more invasive extraction methods and hence should be included in standard procedures for extraction. Indian Orthopaedic Research Group 2021-05 /pmc/articles/PMC8422007/ /pubmed/34557436 http://dx.doi.org/10.13107/jocr.2021.v11.i05.2196 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Garg, Bipul K
Dave, Harshit
Extraction of Broken Tibial Interlock Nail with a Retrograde Hooked Guide Wire: A Novel Surgical Technique
title Extraction of Broken Tibial Interlock Nail with a Retrograde Hooked Guide Wire: A Novel Surgical Technique
title_full Extraction of Broken Tibial Interlock Nail with a Retrograde Hooked Guide Wire: A Novel Surgical Technique
title_fullStr Extraction of Broken Tibial Interlock Nail with a Retrograde Hooked Guide Wire: A Novel Surgical Technique
title_full_unstemmed Extraction of Broken Tibial Interlock Nail with a Retrograde Hooked Guide Wire: A Novel Surgical Technique
title_short Extraction of Broken Tibial Interlock Nail with a Retrograde Hooked Guide Wire: A Novel Surgical Technique
title_sort extraction of broken tibial interlock nail with a retrograde hooked guide wire: a novel surgical technique
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8422007/
https://www.ncbi.nlm.nih.gov/pubmed/34557436
http://dx.doi.org/10.13107/jocr.2021.v11.i05.2196
work_keys_str_mv AT gargbipulk extractionofbrokentibialinterlocknailwitharetrogradehookedguidewireanovelsurgicaltechnique
AT daveharshit extractionofbrokentibialinterlocknailwitharetrogradehookedguidewireanovelsurgicaltechnique