Cargando…

Assessment of atrial septal defect using 2D or real-time 3D transesophageal echocardiography and outcomes following transcatheter closure

BACKGROUND: The assessment of interatrial septum (IAS) requires a standardized, systematic approach, including two-dimensional transthoracic echocardiography (2D TTE), 2D transesophageal echocardiography (2D TEE), and three-dimensional (3D) TEE. Although 2D TEE has been widely used for the preoperat...

Descripción completa

Detalles Bibliográficos
Autores principales: Deng, Bingqing, Chen, Kequan, Huang, Tucheng, Wei, Yulin, Liu, Yingmei, Yang, Li, Qiu, Qiong, Zheng, Shaoxin, Lv, Hanlu, Wang, Peiwei, Nie, Ruqiong, Wang, Jingfeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8422086/
https://www.ncbi.nlm.nih.gov/pubmed/34532446
http://dx.doi.org/10.21037/atm-21-3206
_version_ 1783749215800786944
author Deng, Bingqing
Chen, Kequan
Huang, Tucheng
Wei, Yulin
Liu, Yingmei
Yang, Li
Qiu, Qiong
Zheng, Shaoxin
Lv, Hanlu
Wang, Peiwei
Nie, Ruqiong
Wang, Jingfeng
author_facet Deng, Bingqing
Chen, Kequan
Huang, Tucheng
Wei, Yulin
Liu, Yingmei
Yang, Li
Qiu, Qiong
Zheng, Shaoxin
Lv, Hanlu
Wang, Peiwei
Nie, Ruqiong
Wang, Jingfeng
author_sort Deng, Bingqing
collection PubMed
description BACKGROUND: The assessment of interatrial septum (IAS) requires a standardized, systematic approach, including two-dimensional transthoracic echocardiography (2D TTE), 2D transesophageal echocardiography (2D TEE), and three-dimensional (3D) TEE. Although 2D TEE has been widely used for the preoperative assessment of atrial septal defect (ASD), its ability to provide reliable information is often limited due to the structural characteristics of IAS. The introduction of 3D TEE provides a unique “en face” view of IAS, which allows the visualization and accurate measurements of diameters, area, and rims of ASD. Hence, appropriate ASD imaging information is particularly important in successful transcatheter closure. METHODS: In this retrospective study, 2D TTE/TEE, and 3D TEE were performed before ASD closure, with 2D minimal and maximal diameters, areas, and residual rims being recorded. Adequate 3D TEE imaging data sets were collected and then analyzed. ASD related parameters were compared using different echocardiography. Patients who underwent ASD closure completed a clinical follow-up. RESULTS: The mean defect maximal diameter and aperture area by 3D TEE was significantly larger than that of the corresponding 2D TEE (P<0.05). There was no statistical difference in the minimal and maximal diameter or area by TEE for circular-shaped ASDs. For oval ASDs, mean minimal diameter on 2D TEE was larger than that on 3D TEE. The mean maximal diameter measured using 2D TEE was smaller than the 3D TEE measurement (16.0±7.1 vs. 19.8±8.6; P<0.05). For complex-shaped defects, there were statistical differences in minimal and maximal diameter between TEEs. Furthermore, 2D and 3D TEE had a longer superior vena cava (SVC) residual rim than did 2D TTE (P<0.05). The 3D TEE residual rims of the inferior vena cava (IVC) was significantly larger than the corresponding 2D TEE. There was a very strong correlation between the residual rim measurements using 3D and 2D TEE. However, the limits of agreement between 2D and real-time 3D TEE measurements were more apparent in the IVC rim group than in the other groups. CONCLUSIONS: Our study confirms the value of 3D TEE in assessing ASD shape and size reported by previous studies, and is also the first to accurately and systematically characterize ASD residual rim in complex ASDs.
format Online
Article
Text
id pubmed-8422086
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-84220862021-09-15 Assessment of atrial septal defect using 2D or real-time 3D transesophageal echocardiography and outcomes following transcatheter closure Deng, Bingqing Chen, Kequan Huang, Tucheng Wei, Yulin Liu, Yingmei Yang, Li Qiu, Qiong Zheng, Shaoxin Lv, Hanlu Wang, Peiwei Nie, Ruqiong Wang, Jingfeng Ann Transl Med Original Article BACKGROUND: The assessment of interatrial septum (IAS) requires a standardized, systematic approach, including two-dimensional transthoracic echocardiography (2D TTE), 2D transesophageal echocardiography (2D TEE), and three-dimensional (3D) TEE. Although 2D TEE has been widely used for the preoperative assessment of atrial septal defect (ASD), its ability to provide reliable information is often limited due to the structural characteristics of IAS. The introduction of 3D TEE provides a unique “en face” view of IAS, which allows the visualization and accurate measurements of diameters, area, and rims of ASD. Hence, appropriate ASD imaging information is particularly important in successful transcatheter closure. METHODS: In this retrospective study, 2D TTE/TEE, and 3D TEE were performed before ASD closure, with 2D minimal and maximal diameters, areas, and residual rims being recorded. Adequate 3D TEE imaging data sets were collected and then analyzed. ASD related parameters were compared using different echocardiography. Patients who underwent ASD closure completed a clinical follow-up. RESULTS: The mean defect maximal diameter and aperture area by 3D TEE was significantly larger than that of the corresponding 2D TEE (P<0.05). There was no statistical difference in the minimal and maximal diameter or area by TEE for circular-shaped ASDs. For oval ASDs, mean minimal diameter on 2D TEE was larger than that on 3D TEE. The mean maximal diameter measured using 2D TEE was smaller than the 3D TEE measurement (16.0±7.1 vs. 19.8±8.6; P<0.05). For complex-shaped defects, there were statistical differences in minimal and maximal diameter between TEEs. Furthermore, 2D and 3D TEE had a longer superior vena cava (SVC) residual rim than did 2D TTE (P<0.05). The 3D TEE residual rims of the inferior vena cava (IVC) was significantly larger than the corresponding 2D TEE. There was a very strong correlation between the residual rim measurements using 3D and 2D TEE. However, the limits of agreement between 2D and real-time 3D TEE measurements were more apparent in the IVC rim group than in the other groups. CONCLUSIONS: Our study confirms the value of 3D TEE in assessing ASD shape and size reported by previous studies, and is also the first to accurately and systematically characterize ASD residual rim in complex ASDs. AME Publishing Company 2021-08 /pmc/articles/PMC8422086/ /pubmed/34532446 http://dx.doi.org/10.21037/atm-21-3206 Text en 2021 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Deng, Bingqing
Chen, Kequan
Huang, Tucheng
Wei, Yulin
Liu, Yingmei
Yang, Li
Qiu, Qiong
Zheng, Shaoxin
Lv, Hanlu
Wang, Peiwei
Nie, Ruqiong
Wang, Jingfeng
Assessment of atrial septal defect using 2D or real-time 3D transesophageal echocardiography and outcomes following transcatheter closure
title Assessment of atrial septal defect using 2D or real-time 3D transesophageal echocardiography and outcomes following transcatheter closure
title_full Assessment of atrial septal defect using 2D or real-time 3D transesophageal echocardiography and outcomes following transcatheter closure
title_fullStr Assessment of atrial septal defect using 2D or real-time 3D transesophageal echocardiography and outcomes following transcatheter closure
title_full_unstemmed Assessment of atrial septal defect using 2D or real-time 3D transesophageal echocardiography and outcomes following transcatheter closure
title_short Assessment of atrial septal defect using 2D or real-time 3D transesophageal echocardiography and outcomes following transcatheter closure
title_sort assessment of atrial septal defect using 2d or real-time 3d transesophageal echocardiography and outcomes following transcatheter closure
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8422086/
https://www.ncbi.nlm.nih.gov/pubmed/34532446
http://dx.doi.org/10.21037/atm-21-3206
work_keys_str_mv AT dengbingqing assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT chenkequan assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT huangtucheng assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT weiyulin assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT liuyingmei assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT yangli assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT qiuqiong assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT zhengshaoxin assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT lvhanlu assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT wangpeiwei assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT nieruqiong assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure
AT wangjingfeng assessmentofatrialseptaldefectusing2dorrealtime3dtransesophagealechocardiographyandoutcomesfollowingtranscatheterclosure