Cargando…

A dual-quenched ECL immunosensor for ultrasensitive detection of retinol binding protein 4 based on luminol@AuPt/ZIF-67 and MnO(2)@CNTs

BACKGROUND: Retinol binding protein 4 (RBP4) has been regarded as an important serological biomarker for type 2 diabetes mellitus (T2DM). Hence, the construction of a highly sensitive detection method for RBP4 is the key to early prevention and multidisciplinary intervention of T2DM. In this work, a...

Descripción completa

Detalles Bibliográficos
Autores principales: Gong, Wei, Yang, Suqing, Zhang, Fen, Tian, Fengshun, Chen, Junman, Yin, Zhigang, Ding, Shijia, Yang, Wei, Luo, Rong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8425071/
https://www.ncbi.nlm.nih.gov/pubmed/34496877
http://dx.doi.org/10.1186/s12951-021-01020-1
Descripción
Sumario:BACKGROUND: Retinol binding protein 4 (RBP4) has been regarded as an important serological biomarker for type 2 diabetes mellitus (T2DM). Hence, the construction of a highly sensitive detection method for RBP4 is the key to early prevention and multidisciplinary intervention of T2DM. In this work, a dual-quenched electrochemiluminescence (ECL) immunosensor has been fabricated for ultrasensitive detection of RBP4 by combining zeolitic imidazolate framework-67/AuPt-supported luminol (luminol@AuPt/ZIF-67) with MnO(2) nanosheets-grown on carbon nanotubes (MnO(2)@CNTs). RESULTS: AuPt/ZIF-67 hybrids with high-efficiency peroxidase-like activity could provide multipoint binding sites for luminol and antibodies and significantly boost the amplified initial signal of the ECL immunosensor. Upon glutathione/H(2)O(2) coreactants system, MnO(2)@CNTs composites could quench the initial signal by inhibiting mimic peroxidase activity of luminol@AuPt/ZIF-67. Moreover, the absorption spectrum of the MnO(2)@CNTs composites completely overlaps with the emission spectrum of luminol, which can further reduce initial signal by ECL resonance energy transfer (ECL-RET). CONCLUSIONS: Benefiting from the above-mentioned properties, the designed immunoassay sensitivity exhibited excellent sensitivity and relative stability for RBP4 detection range from 0.0001 to 100 ng mL(−1) with a low detection limit of 43 fg mL(−1). Therefore, our ECL immunosensor provides an alternative assaying strategy for early diagnosis of T2DM. GRAPHIC ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12951-021-01020-1.