Cargando…

Anthropometric measurements of non-arthritic knees in an Egyptian population: an MRI-based study

BACKGROUND: Knee anthropometric characteristics were evaluated for different ethnicities; however, data from North African populations are deficient. The primary aim was to investigate the Egyptian knees’ anthropometric characteristics as a representative of North African populations. Secondary aims...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdelnasser, Mohammad Kamal, Khalifa, Ahmed A., Bassem, Micheal, Abdelhameed, Mohammed Anter, Adam, Mahmoud Faisal, Bakr, Hatem M., Khalifa, Yaser E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8425145/
https://www.ncbi.nlm.nih.gov/pubmed/34496904
http://dx.doi.org/10.1186/s13018-021-02708-8
Descripción
Sumario:BACKGROUND: Knee anthropometric characteristics were evaluated for different ethnicities; however, data from North African populations are deficient. The primary aim was to investigate the Egyptian knees’ anthropometric characteristics as a representative of North African populations. Secondary aims are as follows: (1) to study the anthropometric gender difference, (2) to compare results with other ethnic groups, and (3) to study the mismatch in comparison to geometric characteristics of modern TKA implant designs. METHODS: Two hundred normal knee MRI scans (100 females and 100 males, aging from 18 to 60) were obtained for analysis. Linear measurements (anteroposterior (AP), mediolateral (ML), and aspect ratio (AR)) of the planned cut surface of the distal femur (f) and the proximal tibia (t) were evaluated. RESULTS: A significant difference between both sexes was found, males had larger measurements in anteroposterior [fAP: 60.97 ± 3.1 vs 54.78 ± 3.3 (P < 0.001), tAP: 46.89 ± 3.0 vs 41.35 ± 2.9 (P < 0.001)] and mediolateral [fML: 74.89 ± 3.2 vs 67.29 ± 3.7 (P < 0.001), tML: 76.01 ± 3.0 vs 67.26 ± 3.2 (P < 0.001)], the mean femoral and tibial AP and ML measurements were different from other ethnic groups. None of the seven studied TKA systems matched the largest ML or the smallest AP dimensions of the distal femur in the current study population. CONCLUSION: A significant difference was found between males’ and females’ knee anthropometric characteristics. Some of the commonly used TKA implants in our area could not provide a perfect fit and coverage. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03622034, registered on July 28, 2018.