Cargando…

Peripapillary vessel density measurement of quadrant and clock-hour sectors in primary angle closure glaucoma using optical coherence tomography angiography

BACKGROUND: The purpose of this study was to investigate diagnostic ability of peripapillary vessel density of primary angle closure glaucoma (PACG) eyes in quadrant and clock-hour sectors by optical coherence tomography angiography (OCTA). METHODS: This was a cross-sectional study on forty-one PACG...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Yongdong, Chen, Shirong, Zhang, Mingzhi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8428096/
https://www.ncbi.nlm.nih.gov/pubmed/34503457
http://dx.doi.org/10.1186/s12886-021-02093-0
_version_ 1783750311082459136
author Lin, Yongdong
Chen, Shirong
Zhang, Mingzhi
author_facet Lin, Yongdong
Chen, Shirong
Zhang, Mingzhi
author_sort Lin, Yongdong
collection PubMed
description BACKGROUND: The purpose of this study was to investigate diagnostic ability of peripapillary vessel density of primary angle closure glaucoma (PACG) eyes in quadrant and clock-hour sectors by optical coherence tomography angiography (OCTA). METHODS: This was a cross-sectional study on forty-one PACG patients (41eyes) and twenty-seven healthy subjects (27 eyes). All subjects underwent OCTA (DRI OCT Triton; Topcon Corporation, Tokyo, Japan) and peripapillary retinal nerve fiber layer (RNFL) thickness imaging with swept-source optical coherence tomography (OCT). The peripapillary vessel density of quadrant and clock-hour sectors was quantified by imageJ software. The diagnostic capability of OCTA and OCT parameters was evaluated by the areas under the receiver operating characteristics curves (AUCs). Pearson correlation analysis or Spearman correlation test was used to evaluate the correlation between vessel density parameters and related factors. RESULTS: Compared with the control group, the peripapillary vessel density of glaucomatous group was lower to different degrees in the four quadrants and each clock-hour sectors, and vessel density reduced most at 7 o’clock. The difference between the diagnostic ability of peripapillary vessel density and peripapillary RNFL thickness was not statistically significant, except 4 o’clock and inferior quadrant. The inferior quadrant peripapillary vessel density had the best diagnostic value (AUC0.969), followed by the 7 o’clock vessel density (AUC0.964), average vessel density (AUC0.939) and the 7 o’clock RNFL thickness (AUC0.919). The average peripapillary vessel density was correlated with average RNFL and visual field (VF) mean deviation (P < 0.001). CONCLUSIONS: In PACG, the diagnostic ability of the peripapillary vessel density is equivalent to the peripapillary RNFL thickness. Understanding spatial characteristics of the peripapillary vessel density in PACG may be helpful for clinical diagnosis and monitoring the progress of diseases.
format Online
Article
Text
id pubmed-8428096
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-84280962021-09-10 Peripapillary vessel density measurement of quadrant and clock-hour sectors in primary angle closure glaucoma using optical coherence tomography angiography Lin, Yongdong Chen, Shirong Zhang, Mingzhi BMC Ophthalmol Research BACKGROUND: The purpose of this study was to investigate diagnostic ability of peripapillary vessel density of primary angle closure glaucoma (PACG) eyes in quadrant and clock-hour sectors by optical coherence tomography angiography (OCTA). METHODS: This was a cross-sectional study on forty-one PACG patients (41eyes) and twenty-seven healthy subjects (27 eyes). All subjects underwent OCTA (DRI OCT Triton; Topcon Corporation, Tokyo, Japan) and peripapillary retinal nerve fiber layer (RNFL) thickness imaging with swept-source optical coherence tomography (OCT). The peripapillary vessel density of quadrant and clock-hour sectors was quantified by imageJ software. The diagnostic capability of OCTA and OCT parameters was evaluated by the areas under the receiver operating characteristics curves (AUCs). Pearson correlation analysis or Spearman correlation test was used to evaluate the correlation between vessel density parameters and related factors. RESULTS: Compared with the control group, the peripapillary vessel density of glaucomatous group was lower to different degrees in the four quadrants and each clock-hour sectors, and vessel density reduced most at 7 o’clock. The difference between the diagnostic ability of peripapillary vessel density and peripapillary RNFL thickness was not statistically significant, except 4 o’clock and inferior quadrant. The inferior quadrant peripapillary vessel density had the best diagnostic value (AUC0.969), followed by the 7 o’clock vessel density (AUC0.964), average vessel density (AUC0.939) and the 7 o’clock RNFL thickness (AUC0.919). The average peripapillary vessel density was correlated with average RNFL and visual field (VF) mean deviation (P < 0.001). CONCLUSIONS: In PACG, the diagnostic ability of the peripapillary vessel density is equivalent to the peripapillary RNFL thickness. Understanding spatial characteristics of the peripapillary vessel density in PACG may be helpful for clinical diagnosis and monitoring the progress of diseases. BioMed Central 2021-09-09 /pmc/articles/PMC8428096/ /pubmed/34503457 http://dx.doi.org/10.1186/s12886-021-02093-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Lin, Yongdong
Chen, Shirong
Zhang, Mingzhi
Peripapillary vessel density measurement of quadrant and clock-hour sectors in primary angle closure glaucoma using optical coherence tomography angiography
title Peripapillary vessel density measurement of quadrant and clock-hour sectors in primary angle closure glaucoma using optical coherence tomography angiography
title_full Peripapillary vessel density measurement of quadrant and clock-hour sectors in primary angle closure glaucoma using optical coherence tomography angiography
title_fullStr Peripapillary vessel density measurement of quadrant and clock-hour sectors in primary angle closure glaucoma using optical coherence tomography angiography
title_full_unstemmed Peripapillary vessel density measurement of quadrant and clock-hour sectors in primary angle closure glaucoma using optical coherence tomography angiography
title_short Peripapillary vessel density measurement of quadrant and clock-hour sectors in primary angle closure glaucoma using optical coherence tomography angiography
title_sort peripapillary vessel density measurement of quadrant and clock-hour sectors in primary angle closure glaucoma using optical coherence tomography angiography
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8428096/
https://www.ncbi.nlm.nih.gov/pubmed/34503457
http://dx.doi.org/10.1186/s12886-021-02093-0
work_keys_str_mv AT linyongdong peripapillaryvesseldensitymeasurementofquadrantandclockhoursectorsinprimaryangleclosureglaucomausingopticalcoherencetomographyangiography
AT chenshirong peripapillaryvesseldensitymeasurementofquadrantandclockhoursectorsinprimaryangleclosureglaucomausingopticalcoherencetomographyangiography
AT zhangmingzhi peripapillaryvesseldensitymeasurementofquadrantandclockhoursectorsinprimaryangleclosureglaucomausingopticalcoherencetomographyangiography