Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis

Hybrid locking pancarpal arthrodesis plates were designed with either a round (RH) or an oval (OH) radiocarpal hole, the latter allowing varied screw positioning. Due to concerns about potential decreased structural properties of the OH design, our aim was to compare the mechanical behavior of the c...

Descripción completa

Detalles Bibliográficos
Autores principales: Zderic, Ivan, Varga, Peter, Styger, Ursula, Drenchev, Ludmil, Gueorguiev, Boyko, Asimus, Erik, Saunders, W. Brian, Kowaleski, Michael, Boudrieau, Randy J., Dejardin, Loic M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8429002/
https://www.ncbi.nlm.nih.gov/pubmed/34513988
http://dx.doi.org/10.1155/2021/2526879
_version_ 1783750481536876544
author Zderic, Ivan
Varga, Peter
Styger, Ursula
Drenchev, Ludmil
Gueorguiev, Boyko
Asimus, Erik
Saunders, W. Brian
Kowaleski, Michael
Boudrieau, Randy J.
Dejardin, Loic M.
author_facet Zderic, Ivan
Varga, Peter
Styger, Ursula
Drenchev, Ludmil
Gueorguiev, Boyko
Asimus, Erik
Saunders, W. Brian
Kowaleski, Michael
Boudrieau, Randy J.
Dejardin, Loic M.
author_sort Zderic, Ivan
collection PubMed
description Hybrid locking pancarpal arthrodesis plates were designed with either a round (RH) or an oval (OH) radiocarpal hole, the latter allowing varied screw positioning. Due to concerns about potential decreased structural properties of the OH design, our aim was to compare the mechanical behavior of the contrasting plates using combined finite element analysis (FEA) and mechanical testing. Pancarpal arthrodesis plates with RH or OH design were assigned to three fixation techniques (n = 6), prebent at 20°, and fixed to canine forelimb models with simulated radius and radiocarpal and 3rd metacarpal bones. OH plates were instrumented with a radiocarpal screw inserted either most proximal (OH-P) or most distal (OH-D). Specimens were axially loaded to 300 N over 10 ramped cycles at 0.5 Hz. Plate strains were measured with strain gauges placed at areas of highest deformations as predicted by FEA under identical loading conditions. FEA predicted the highest strains (μm/m) adjacent to the radiocarpal hole (2,500 [RH], 2,900 [OH-P/OH-D]) and plate bending point (2,250 [RH], 1,900 [OH-P/OH-D]). Experimentally, peak radiocarpal hole strains were not influenced by the OH screw position (3,329 ± 443 [OH-P], 3,222 ± 467 [OH-D]; P = 0.550) but were significantly higher compared to the RH design (2,123 ± 154; P < 0.001). Peak strains at the bending point were significantly lower for OH-P (1,792 ± 174) and OH-D (1,806 ± 194) versus RH configurations (2,158 ± 114) (P ≤ 0.006). OH plates demonstrated highest peak strains next to the radiocarpal hole and were associated with more heterogenous plate strain distribution. Structural weakening associated with radiocarpal OH plate design could result in decreased fixation strength and increased risk of plate fatigue failure.
format Online
Article
Text
id pubmed-8429002
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-84290022021-09-10 Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis Zderic, Ivan Varga, Peter Styger, Ursula Drenchev, Ludmil Gueorguiev, Boyko Asimus, Erik Saunders, W. Brian Kowaleski, Michael Boudrieau, Randy J. Dejardin, Loic M. Biomed Res Int Research Article Hybrid locking pancarpal arthrodesis plates were designed with either a round (RH) or an oval (OH) radiocarpal hole, the latter allowing varied screw positioning. Due to concerns about potential decreased structural properties of the OH design, our aim was to compare the mechanical behavior of the contrasting plates using combined finite element analysis (FEA) and mechanical testing. Pancarpal arthrodesis plates with RH or OH design were assigned to three fixation techniques (n = 6), prebent at 20°, and fixed to canine forelimb models with simulated radius and radiocarpal and 3rd metacarpal bones. OH plates were instrumented with a radiocarpal screw inserted either most proximal (OH-P) or most distal (OH-D). Specimens were axially loaded to 300 N over 10 ramped cycles at 0.5 Hz. Plate strains were measured with strain gauges placed at areas of highest deformations as predicted by FEA under identical loading conditions. FEA predicted the highest strains (μm/m) adjacent to the radiocarpal hole (2,500 [RH], 2,900 [OH-P/OH-D]) and plate bending point (2,250 [RH], 1,900 [OH-P/OH-D]). Experimentally, peak radiocarpal hole strains were not influenced by the OH screw position (3,329 ± 443 [OH-P], 3,222 ± 467 [OH-D]; P = 0.550) but were significantly higher compared to the RH design (2,123 ± 154; P < 0.001). Peak strains at the bending point were significantly lower for OH-P (1,792 ± 174) and OH-D (1,806 ± 194) versus RH configurations (2,158 ± 114) (P ≤ 0.006). OH plates demonstrated highest peak strains next to the radiocarpal hole and were associated with more heterogenous plate strain distribution. Structural weakening associated with radiocarpal OH plate design could result in decreased fixation strength and increased risk of plate fatigue failure. Hindawi 2021-09-02 /pmc/articles/PMC8429002/ /pubmed/34513988 http://dx.doi.org/10.1155/2021/2526879 Text en Copyright © 2021 Ivan Zderic et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zderic, Ivan
Varga, Peter
Styger, Ursula
Drenchev, Ludmil
Gueorguiev, Boyko
Asimus, Erik
Saunders, W. Brian
Kowaleski, Michael
Boudrieau, Randy J.
Dejardin, Loic M.
Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis
title Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis
title_full Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis
title_fullStr Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis
title_full_unstemmed Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis
title_short Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis
title_sort mechanical evaluation of two hybrid locking plate designs for canine pancarpal arthrodesis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8429002/
https://www.ncbi.nlm.nih.gov/pubmed/34513988
http://dx.doi.org/10.1155/2021/2526879
work_keys_str_mv AT zdericivan mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis
AT vargapeter mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis
AT stygerursula mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis
AT drenchevludmil mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis
AT gueorguievboyko mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis
AT asimuserik mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis
AT saunderswbrian mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis
AT kowaleskimichael mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis
AT boudrieaurandyj mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis
AT dejardinloicm mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis