Cargando…
Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis
Hybrid locking pancarpal arthrodesis plates were designed with either a round (RH) or an oval (OH) radiocarpal hole, the latter allowing varied screw positioning. Due to concerns about potential decreased structural properties of the OH design, our aim was to compare the mechanical behavior of the c...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8429002/ https://www.ncbi.nlm.nih.gov/pubmed/34513988 http://dx.doi.org/10.1155/2021/2526879 |
_version_ | 1783750481536876544 |
---|---|
author | Zderic, Ivan Varga, Peter Styger, Ursula Drenchev, Ludmil Gueorguiev, Boyko Asimus, Erik Saunders, W. Brian Kowaleski, Michael Boudrieau, Randy J. Dejardin, Loic M. |
author_facet | Zderic, Ivan Varga, Peter Styger, Ursula Drenchev, Ludmil Gueorguiev, Boyko Asimus, Erik Saunders, W. Brian Kowaleski, Michael Boudrieau, Randy J. Dejardin, Loic M. |
author_sort | Zderic, Ivan |
collection | PubMed |
description | Hybrid locking pancarpal arthrodesis plates were designed with either a round (RH) or an oval (OH) radiocarpal hole, the latter allowing varied screw positioning. Due to concerns about potential decreased structural properties of the OH design, our aim was to compare the mechanical behavior of the contrasting plates using combined finite element analysis (FEA) and mechanical testing. Pancarpal arthrodesis plates with RH or OH design were assigned to three fixation techniques (n = 6), prebent at 20°, and fixed to canine forelimb models with simulated radius and radiocarpal and 3rd metacarpal bones. OH plates were instrumented with a radiocarpal screw inserted either most proximal (OH-P) or most distal (OH-D). Specimens were axially loaded to 300 N over 10 ramped cycles at 0.5 Hz. Plate strains were measured with strain gauges placed at areas of highest deformations as predicted by FEA under identical loading conditions. FEA predicted the highest strains (μm/m) adjacent to the radiocarpal hole (2,500 [RH], 2,900 [OH-P/OH-D]) and plate bending point (2,250 [RH], 1,900 [OH-P/OH-D]). Experimentally, peak radiocarpal hole strains were not influenced by the OH screw position (3,329 ± 443 [OH-P], 3,222 ± 467 [OH-D]; P = 0.550) but were significantly higher compared to the RH design (2,123 ± 154; P < 0.001). Peak strains at the bending point were significantly lower for OH-P (1,792 ± 174) and OH-D (1,806 ± 194) versus RH configurations (2,158 ± 114) (P ≤ 0.006). OH plates demonstrated highest peak strains next to the radiocarpal hole and were associated with more heterogenous plate strain distribution. Structural weakening associated with radiocarpal OH plate design could result in decreased fixation strength and increased risk of plate fatigue failure. |
format | Online Article Text |
id | pubmed-8429002 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-84290022021-09-10 Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis Zderic, Ivan Varga, Peter Styger, Ursula Drenchev, Ludmil Gueorguiev, Boyko Asimus, Erik Saunders, W. Brian Kowaleski, Michael Boudrieau, Randy J. Dejardin, Loic M. Biomed Res Int Research Article Hybrid locking pancarpal arthrodesis plates were designed with either a round (RH) or an oval (OH) radiocarpal hole, the latter allowing varied screw positioning. Due to concerns about potential decreased structural properties of the OH design, our aim was to compare the mechanical behavior of the contrasting plates using combined finite element analysis (FEA) and mechanical testing. Pancarpal arthrodesis plates with RH or OH design were assigned to three fixation techniques (n = 6), prebent at 20°, and fixed to canine forelimb models with simulated radius and radiocarpal and 3rd metacarpal bones. OH plates were instrumented with a radiocarpal screw inserted either most proximal (OH-P) or most distal (OH-D). Specimens were axially loaded to 300 N over 10 ramped cycles at 0.5 Hz. Plate strains were measured with strain gauges placed at areas of highest deformations as predicted by FEA under identical loading conditions. FEA predicted the highest strains (μm/m) adjacent to the radiocarpal hole (2,500 [RH], 2,900 [OH-P/OH-D]) and plate bending point (2,250 [RH], 1,900 [OH-P/OH-D]). Experimentally, peak radiocarpal hole strains were not influenced by the OH screw position (3,329 ± 443 [OH-P], 3,222 ± 467 [OH-D]; P = 0.550) but were significantly higher compared to the RH design (2,123 ± 154; P < 0.001). Peak strains at the bending point were significantly lower for OH-P (1,792 ± 174) and OH-D (1,806 ± 194) versus RH configurations (2,158 ± 114) (P ≤ 0.006). OH plates demonstrated highest peak strains next to the radiocarpal hole and were associated with more heterogenous plate strain distribution. Structural weakening associated with radiocarpal OH plate design could result in decreased fixation strength and increased risk of plate fatigue failure. Hindawi 2021-09-02 /pmc/articles/PMC8429002/ /pubmed/34513988 http://dx.doi.org/10.1155/2021/2526879 Text en Copyright © 2021 Ivan Zderic et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zderic, Ivan Varga, Peter Styger, Ursula Drenchev, Ludmil Gueorguiev, Boyko Asimus, Erik Saunders, W. Brian Kowaleski, Michael Boudrieau, Randy J. Dejardin, Loic M. Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis |
title | Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis |
title_full | Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis |
title_fullStr | Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis |
title_full_unstemmed | Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis |
title_short | Mechanical Evaluation of Two Hybrid Locking Plate Designs for Canine Pancarpal Arthrodesis |
title_sort | mechanical evaluation of two hybrid locking plate designs for canine pancarpal arthrodesis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8429002/ https://www.ncbi.nlm.nih.gov/pubmed/34513988 http://dx.doi.org/10.1155/2021/2526879 |
work_keys_str_mv | AT zdericivan mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis AT vargapeter mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis AT stygerursula mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis AT drenchevludmil mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis AT gueorguievboyko mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis AT asimuserik mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis AT saunderswbrian mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis AT kowaleskimichael mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis AT boudrieaurandyj mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis AT dejardinloicm mechanicalevaluationoftwohybridlockingplatedesignsforcaninepancarpalarthrodesis |