Cargando…

The Use of Maximum Entropy to Enhance Wave Intensity Analysis: An Application to Coronary Arteries in Hypertrophic Obstructive Cardiomyopathy

Background: Wave intensity analysis is useful for analyzing coronary hemodynamics. Much of its clinical application involves the identification of waves indicated by peaks in the wave intensity and relating their presence or absence to different cardiovascular events. However, the analysis of wave i...

Descripción completa

Detalles Bibliográficos
Autores principales: Francis, Nadine, Selwanos, Peter P., Yacoub, Magdi H., Parker, Kim H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8429819/
https://www.ncbi.nlm.nih.gov/pubmed/34513947
http://dx.doi.org/10.3389/fcvm.2021.701267
_version_ 1783750611116752896
author Francis, Nadine
Selwanos, Peter P.
Yacoub, Magdi H.
Parker, Kim H.
author_facet Francis, Nadine
Selwanos, Peter P.
Yacoub, Magdi H.
Parker, Kim H.
author_sort Francis, Nadine
collection PubMed
description Background: Wave intensity analysis is useful for analyzing coronary hemodynamics. Much of its clinical application involves the identification of waves indicated by peaks in the wave intensity and relating their presence or absence to different cardiovascular events. However, the analysis of wave intensity peaks can be problematic because of the associated noise in the measurements. This study shows how wave intensity analysis can be enhanced by using a Maximum Entropy Method (MEM). Methods: We introduce a MEM to differentiate between “peaks” and “background” in wave intensity waveforms. We apply the method to the wave intensity waveforms measured in the left anterior descending coronary artery from 10 Hypertrophic Obstructive Cardiomyopathy (HOCM) and 11 Controls with normal cardiac function. We propose a naming convention for the significant waves and compare them across the cohorts. Results: Using a MEM enhances wave intensity analysis by identifying twice as many significant waves as previous studies. The results are robust when MEM is applied to the log transformed wave intensity data and when all of the measured data are used. Comparing waves across cohorts, we suggest that the absence of a forward expansion wave in HOCM can be taken as an indication of HOCM. Our results also indicate that the backward compression waves in HOCM are significantly larger than in Controls; unlike the forward compression waves where the wave energy in Controls is significantly higher than in HOCM. Comparing the smaller secondary waves revealed by MEM, we find some waves that are present in the majority of Controls and absent in almost all HOCM, and other waves that are present in some HOCM patients but entirely absent in Controls. This suggests some diagnostic utility in the clinical measurement of these waves, which can be a positive sign of HOCM or a subgroup with a particular pathology. Conclusion: The MEM enhances wave intensity analysis by identifying many more significant waves. The method is novel and can be applied to wave intensity analysis in all arteries. As an example, we show how it can be useful in the clinical study of hemodynamics in the coronary arteries in HOCM.
format Online
Article
Text
id pubmed-8429819
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-84298192021-09-11 The Use of Maximum Entropy to Enhance Wave Intensity Analysis: An Application to Coronary Arteries in Hypertrophic Obstructive Cardiomyopathy Francis, Nadine Selwanos, Peter P. Yacoub, Magdi H. Parker, Kim H. Front Cardiovasc Med Cardiovascular Medicine Background: Wave intensity analysis is useful for analyzing coronary hemodynamics. Much of its clinical application involves the identification of waves indicated by peaks in the wave intensity and relating their presence or absence to different cardiovascular events. However, the analysis of wave intensity peaks can be problematic because of the associated noise in the measurements. This study shows how wave intensity analysis can be enhanced by using a Maximum Entropy Method (MEM). Methods: We introduce a MEM to differentiate between “peaks” and “background” in wave intensity waveforms. We apply the method to the wave intensity waveforms measured in the left anterior descending coronary artery from 10 Hypertrophic Obstructive Cardiomyopathy (HOCM) and 11 Controls with normal cardiac function. We propose a naming convention for the significant waves and compare them across the cohorts. Results: Using a MEM enhances wave intensity analysis by identifying twice as many significant waves as previous studies. The results are robust when MEM is applied to the log transformed wave intensity data and when all of the measured data are used. Comparing waves across cohorts, we suggest that the absence of a forward expansion wave in HOCM can be taken as an indication of HOCM. Our results also indicate that the backward compression waves in HOCM are significantly larger than in Controls; unlike the forward compression waves where the wave energy in Controls is significantly higher than in HOCM. Comparing the smaller secondary waves revealed by MEM, we find some waves that are present in the majority of Controls and absent in almost all HOCM, and other waves that are present in some HOCM patients but entirely absent in Controls. This suggests some diagnostic utility in the clinical measurement of these waves, which can be a positive sign of HOCM or a subgroup with a particular pathology. Conclusion: The MEM enhances wave intensity analysis by identifying many more significant waves. The method is novel and can be applied to wave intensity analysis in all arteries. As an example, we show how it can be useful in the clinical study of hemodynamics in the coronary arteries in HOCM. Frontiers Media S.A. 2021-08-27 /pmc/articles/PMC8429819/ /pubmed/34513947 http://dx.doi.org/10.3389/fcvm.2021.701267 Text en Copyright © 2021 Francis, Selwanos, Yacoub and Parker. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Francis, Nadine
Selwanos, Peter P.
Yacoub, Magdi H.
Parker, Kim H.
The Use of Maximum Entropy to Enhance Wave Intensity Analysis: An Application to Coronary Arteries in Hypertrophic Obstructive Cardiomyopathy
title The Use of Maximum Entropy to Enhance Wave Intensity Analysis: An Application to Coronary Arteries in Hypertrophic Obstructive Cardiomyopathy
title_full The Use of Maximum Entropy to Enhance Wave Intensity Analysis: An Application to Coronary Arteries in Hypertrophic Obstructive Cardiomyopathy
title_fullStr The Use of Maximum Entropy to Enhance Wave Intensity Analysis: An Application to Coronary Arteries in Hypertrophic Obstructive Cardiomyopathy
title_full_unstemmed The Use of Maximum Entropy to Enhance Wave Intensity Analysis: An Application to Coronary Arteries in Hypertrophic Obstructive Cardiomyopathy
title_short The Use of Maximum Entropy to Enhance Wave Intensity Analysis: An Application to Coronary Arteries in Hypertrophic Obstructive Cardiomyopathy
title_sort use of maximum entropy to enhance wave intensity analysis: an application to coronary arteries in hypertrophic obstructive cardiomyopathy
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8429819/
https://www.ncbi.nlm.nih.gov/pubmed/34513947
http://dx.doi.org/10.3389/fcvm.2021.701267
work_keys_str_mv AT francisnadine theuseofmaximumentropytoenhancewaveintensityanalysisanapplicationtocoronaryarteriesinhypertrophicobstructivecardiomyopathy
AT selwanospeterp theuseofmaximumentropytoenhancewaveintensityanalysisanapplicationtocoronaryarteriesinhypertrophicobstructivecardiomyopathy
AT yacoubmagdih theuseofmaximumentropytoenhancewaveintensityanalysisanapplicationtocoronaryarteriesinhypertrophicobstructivecardiomyopathy
AT parkerkimh theuseofmaximumentropytoenhancewaveintensityanalysisanapplicationtocoronaryarteriesinhypertrophicobstructivecardiomyopathy
AT francisnadine useofmaximumentropytoenhancewaveintensityanalysisanapplicationtocoronaryarteriesinhypertrophicobstructivecardiomyopathy
AT selwanospeterp useofmaximumentropytoenhancewaveintensityanalysisanapplicationtocoronaryarteriesinhypertrophicobstructivecardiomyopathy
AT yacoubmagdih useofmaximumentropytoenhancewaveintensityanalysisanapplicationtocoronaryarteriesinhypertrophicobstructivecardiomyopathy
AT parkerkimh useofmaximumentropytoenhancewaveintensityanalysisanapplicationtocoronaryarteriesinhypertrophicobstructivecardiomyopathy