Cargando…
Bringing Light into Darkness—Comparison of Different Personal Dosimeters for Assessment of Solar Ultraviolet Exposure
(1) Measuring personal exposure to solar ultraviolet radiation (UVR) poses a major challenges for researchers. Often, the study design determines the measuring devices that can be used, be it the duration of measurements or size restrictions on different body parts. It is therefore of great importan...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8431201/ https://www.ncbi.nlm.nih.gov/pubmed/34501660 http://dx.doi.org/10.3390/ijerph18179071 |
_version_ | 1783750881176453120 |
---|---|
author | Strehl, Claudine Heepenstrick, Timo Knuschke, Peter Wittlich, Marc |
author_facet | Strehl, Claudine Heepenstrick, Timo Knuschke, Peter Wittlich, Marc |
author_sort | Strehl, Claudine |
collection | PubMed |
description | (1) Measuring personal exposure to solar ultraviolet radiation (UVR) poses a major challenges for researchers. Often, the study design determines the measuring devices that can be used, be it the duration of measurements or size restrictions on different body parts. It is therefore of great importance that measuring devices produce comparable results despite technical differences and modes of operation. Particularly when measurement results from different studies dealing with personal UV exposure are to be compared with each other, the need for intercomparability and intercalibration factors between different measurement systems becomes significant. (2) Three commonly used dosimeter types—(polysulphone film (PSF), biological, and electronic dosimeters)—were selected to perform intercalibration measurements. They differ in measurement principle and sensitivity, measurement accuracy, and susceptibility to inaccuracies. The aim was to derive intercalibration factors for these dosimeter types. (3) While a calibration factor between PSF and electronic dosimeters of about 1.3 could be derived for direct irradiation of the dosimeters, this was not the case for larger angles of incidence of solar radiation with increasing fractions of diffuse irradiation. Electronic dosimeters show small standard deviation across all measurements. For biological dosimeters, no intercalibration factor could be found with respect to PSF and electronic dosimeters. In a use case, the relation between steady-state measurements and personal measurements was studied. On average, persons acquired only a small fraction of the ambient radiation. |
format | Online Article Text |
id | pubmed-8431201 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84312012021-09-11 Bringing Light into Darkness—Comparison of Different Personal Dosimeters for Assessment of Solar Ultraviolet Exposure Strehl, Claudine Heepenstrick, Timo Knuschke, Peter Wittlich, Marc Int J Environ Res Public Health Article (1) Measuring personal exposure to solar ultraviolet radiation (UVR) poses a major challenges for researchers. Often, the study design determines the measuring devices that can be used, be it the duration of measurements or size restrictions on different body parts. It is therefore of great importance that measuring devices produce comparable results despite technical differences and modes of operation. Particularly when measurement results from different studies dealing with personal UV exposure are to be compared with each other, the need for intercomparability and intercalibration factors between different measurement systems becomes significant. (2) Three commonly used dosimeter types—(polysulphone film (PSF), biological, and electronic dosimeters)—were selected to perform intercalibration measurements. They differ in measurement principle and sensitivity, measurement accuracy, and susceptibility to inaccuracies. The aim was to derive intercalibration factors for these dosimeter types. (3) While a calibration factor between PSF and electronic dosimeters of about 1.3 could be derived for direct irradiation of the dosimeters, this was not the case for larger angles of incidence of solar radiation with increasing fractions of diffuse irradiation. Electronic dosimeters show small standard deviation across all measurements. For biological dosimeters, no intercalibration factor could be found with respect to PSF and electronic dosimeters. In a use case, the relation between steady-state measurements and personal measurements was studied. On average, persons acquired only a small fraction of the ambient radiation. MDPI 2021-08-27 /pmc/articles/PMC8431201/ /pubmed/34501660 http://dx.doi.org/10.3390/ijerph18179071 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Strehl, Claudine Heepenstrick, Timo Knuschke, Peter Wittlich, Marc Bringing Light into Darkness—Comparison of Different Personal Dosimeters for Assessment of Solar Ultraviolet Exposure |
title | Bringing Light into Darkness—Comparison of Different Personal Dosimeters for Assessment of Solar Ultraviolet Exposure |
title_full | Bringing Light into Darkness—Comparison of Different Personal Dosimeters for Assessment of Solar Ultraviolet Exposure |
title_fullStr | Bringing Light into Darkness—Comparison of Different Personal Dosimeters for Assessment of Solar Ultraviolet Exposure |
title_full_unstemmed | Bringing Light into Darkness—Comparison of Different Personal Dosimeters for Assessment of Solar Ultraviolet Exposure |
title_short | Bringing Light into Darkness—Comparison of Different Personal Dosimeters for Assessment of Solar Ultraviolet Exposure |
title_sort | bringing light into darkness—comparison of different personal dosimeters for assessment of solar ultraviolet exposure |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8431201/ https://www.ncbi.nlm.nih.gov/pubmed/34501660 http://dx.doi.org/10.3390/ijerph18179071 |
work_keys_str_mv | AT strehlclaudine bringinglightintodarknesscomparisonofdifferentpersonaldosimetersforassessmentofsolarultravioletexposure AT heepenstricktimo bringinglightintodarknesscomparisonofdifferentpersonaldosimetersforassessmentofsolarultravioletexposure AT knuschkepeter bringinglightintodarknesscomparisonofdifferentpersonaldosimetersforassessmentofsolarultravioletexposure AT wittlichmarc bringinglightintodarknesscomparisonofdifferentpersonaldosimetersforassessmentofsolarultravioletexposure |