Cargando…
Feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver
BACKGROUND: Simultaneous multislice diffusion-weighted imaging (SMS-DWI) has been used to reduce image acquisition time. The purpose of this study was to investigate the feasibility of diffusion kurtosis imaging (DKI) based on the SMS technique in the liver and the influence of this method compared...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8431937/ https://www.ncbi.nlm.nih.gov/pubmed/34503482 http://dx.doi.org/10.1186/s12880-021-00661-w |
_version_ | 1783751050883235840 |
---|---|
author | Xu, Hui Zhang, Nan Yang, Da-Wei Ren, Ahong Ren, Hao Zhang, Qian Zhu, Jin-Xia Li, Gui-Jin Yang, Zheng-Han |
author_facet | Xu, Hui Zhang, Nan Yang, Da-Wei Ren, Ahong Ren, Hao Zhang, Qian Zhu, Jin-Xia Li, Gui-Jin Yang, Zheng-Han |
author_sort | Xu, Hui |
collection | PubMed |
description | BACKGROUND: Simultaneous multislice diffusion-weighted imaging (SMS-DWI) has been used to reduce image acquisition time. The purpose of this study was to investigate the feasibility of diffusion kurtosis imaging (DKI) based on the SMS technique in the liver and the influence of this method compared with that of conventional DWI sequences on image quality and DKI-derived quantitative parameters. METHODS: Forty volunteers underwent SMS-DWI sequences with acceleration factors of 2 and 3 (SMS2-DWI, SMS3-DWI) and conventional DWI (C-DWI) of the liver with three b-values (50, 800, 2000 s/mm(2)) in a 3T system. Qualitative image quality parameters and quantitative measurements of the signal-to-noise ratio (SNR), mean kurtosis (MK), mean apparent diffusivity (MD) and apparent diffusion coefficient (ADC) for the liver were compared between the three sequences. RESULTS: The scan times of C-DWI, SMS2-DWI, and SMS3-DWI were 4 min 11 s, 2 min 2 s, and 1 min 34 s, respectively. For all image quality parameters, there were no significant differences observed between C-DWI and SMS2-DWI (all p > 0.05) in the images with b-values of 800 and 2000 s/mm(2). C-DWI and SMS2-DWI exhibited better scores than SMS3-DWI (all p < 0.01) in the images with b-values of 2000 s/mm(2). In the images with b-values of 800 s/mm(2), C-DWI and SMS2-DWI exhibited better scores than SMS3-DWI for artefacts and overall image quality (all p < 0.01), and C-DWI exhibited better scores than SMS3-DWI for the visibility of intrahepatic vessels (p < 0.001). There were no significant differences in the sharpness of the right lobe edge (p = 0.144), conspicuity of the left lobe (p = 0.370) or visibility of intrahepatic vessels (p = 0.109) between SMS2-DWI and SMS3-DWI. There were no significant differences in the sharpness of the right lobe edge (p = 0.066) or conspicuity of the left lobe (p = 0.131) between C-DWI and SMS3-DWI. For the b-value of 800 s/mm(2), there were no statistically significant differences between SMS2-DWI and C-DWI (p = 1.000) or between SMS2-DWI and SMS3-DWI (p = 0.059), whereas SMS3-DWI had a significantly lower SNR than C-DWI (p = 0.024). For the DKI-derived parameters (MK and MD) and ADC values, there were no significant differences between the three sequences (MK, p = 0.606; MD, p = 0.831; ADC, p = 0.264). CONCLUSIONS: SMS-DWI with an acceleration factor of 2 is feasible for the liver, resulting in considerable reductions in scan time while maintaining similar image quality, comparable DKI parameters and ADC values compared with those of C-DWI. |
format | Online Article Text |
id | pubmed-8431937 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-84319372021-09-10 Feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver Xu, Hui Zhang, Nan Yang, Da-Wei Ren, Ahong Ren, Hao Zhang, Qian Zhu, Jin-Xia Li, Gui-Jin Yang, Zheng-Han BMC Med Imaging Research BACKGROUND: Simultaneous multislice diffusion-weighted imaging (SMS-DWI) has been used to reduce image acquisition time. The purpose of this study was to investigate the feasibility of diffusion kurtosis imaging (DKI) based on the SMS technique in the liver and the influence of this method compared with that of conventional DWI sequences on image quality and DKI-derived quantitative parameters. METHODS: Forty volunteers underwent SMS-DWI sequences with acceleration factors of 2 and 3 (SMS2-DWI, SMS3-DWI) and conventional DWI (C-DWI) of the liver with three b-values (50, 800, 2000 s/mm(2)) in a 3T system. Qualitative image quality parameters and quantitative measurements of the signal-to-noise ratio (SNR), mean kurtosis (MK), mean apparent diffusivity (MD) and apparent diffusion coefficient (ADC) for the liver were compared between the three sequences. RESULTS: The scan times of C-DWI, SMS2-DWI, and SMS3-DWI were 4 min 11 s, 2 min 2 s, and 1 min 34 s, respectively. For all image quality parameters, there were no significant differences observed between C-DWI and SMS2-DWI (all p > 0.05) in the images with b-values of 800 and 2000 s/mm(2). C-DWI and SMS2-DWI exhibited better scores than SMS3-DWI (all p < 0.01) in the images with b-values of 2000 s/mm(2). In the images with b-values of 800 s/mm(2), C-DWI and SMS2-DWI exhibited better scores than SMS3-DWI for artefacts and overall image quality (all p < 0.01), and C-DWI exhibited better scores than SMS3-DWI for the visibility of intrahepatic vessels (p < 0.001). There were no significant differences in the sharpness of the right lobe edge (p = 0.144), conspicuity of the left lobe (p = 0.370) or visibility of intrahepatic vessels (p = 0.109) between SMS2-DWI and SMS3-DWI. There were no significant differences in the sharpness of the right lobe edge (p = 0.066) or conspicuity of the left lobe (p = 0.131) between C-DWI and SMS3-DWI. For the b-value of 800 s/mm(2), there were no statistically significant differences between SMS2-DWI and C-DWI (p = 1.000) or between SMS2-DWI and SMS3-DWI (p = 0.059), whereas SMS3-DWI had a significantly lower SNR than C-DWI (p = 0.024). For the DKI-derived parameters (MK and MD) and ADC values, there were no significant differences between the three sequences (MK, p = 0.606; MD, p = 0.831; ADC, p = 0.264). CONCLUSIONS: SMS-DWI with an acceleration factor of 2 is feasible for the liver, resulting in considerable reductions in scan time while maintaining similar image quality, comparable DKI parameters and ADC values compared with those of C-DWI. BioMed Central 2021-09-09 /pmc/articles/PMC8431937/ /pubmed/34503482 http://dx.doi.org/10.1186/s12880-021-00661-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Xu, Hui Zhang, Nan Yang, Da-Wei Ren, Ahong Ren, Hao Zhang, Qian Zhu, Jin-Xia Li, Gui-Jin Yang, Zheng-Han Feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver |
title | Feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver |
title_full | Feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver |
title_fullStr | Feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver |
title_full_unstemmed | Feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver |
title_short | Feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver |
title_sort | feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8431937/ https://www.ncbi.nlm.nih.gov/pubmed/34503482 http://dx.doi.org/10.1186/s12880-021-00661-w |
work_keys_str_mv | AT xuhui feasibilitystudyofsimultaneousmultislicediffusionkurtosisimagingwithdifferentaccelerationfactorsintheliver AT zhangnan feasibilitystudyofsimultaneousmultislicediffusionkurtosisimagingwithdifferentaccelerationfactorsintheliver AT yangdawei feasibilitystudyofsimultaneousmultislicediffusionkurtosisimagingwithdifferentaccelerationfactorsintheliver AT renahong feasibilitystudyofsimultaneousmultislicediffusionkurtosisimagingwithdifferentaccelerationfactorsintheliver AT renhao feasibilitystudyofsimultaneousmultislicediffusionkurtosisimagingwithdifferentaccelerationfactorsintheliver AT zhangqian feasibilitystudyofsimultaneousmultislicediffusionkurtosisimagingwithdifferentaccelerationfactorsintheliver AT zhujinxia feasibilitystudyofsimultaneousmultislicediffusionkurtosisimagingwithdifferentaccelerationfactorsintheliver AT liguijin feasibilitystudyofsimultaneousmultislicediffusionkurtosisimagingwithdifferentaccelerationfactorsintheliver AT yangzhenghan feasibilitystudyofsimultaneousmultislicediffusionkurtosisimagingwithdifferentaccelerationfactorsintheliver |