Direct Lateral Corpectomy and Reconstruction Using an Expandable Cage Improves Local Kyphosis but Not Global Sagittal Alignment
Recently, an expandable cage equipped with rectangular footplates has been used for anterior vertebral replacement in osteoporotic vertebral fracture (OVF). However, the postoperative changes in global alignment have not been elucidated. The purpose of this study was to evaluate local and global spi...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8432512/ https://www.ncbi.nlm.nih.gov/pubmed/34501460 http://dx.doi.org/10.3390/jcm10174012 |
_version_ | 1783751183320481792 |
---|---|
author | Terai, Hidetomi Takahashi, Shinji Yasuda, Hiroyuki Konishi, Sadahiko Maeno, Takafumi Kono, Hiroshi Matsumura, Akira Namikawa, Takashi Kato, Minori Hoshino, Masatoshi Tamai, Koji Toyoda, Hiromitsu Suzuki, Akinobu Nakamura, Hiroaki |
author_facet | Terai, Hidetomi Takahashi, Shinji Yasuda, Hiroyuki Konishi, Sadahiko Maeno, Takafumi Kono, Hiroshi Matsumura, Akira Namikawa, Takashi Kato, Minori Hoshino, Masatoshi Tamai, Koji Toyoda, Hiromitsu Suzuki, Akinobu Nakamura, Hiroaki |
author_sort | Terai, Hidetomi |
collection | PubMed |
description | Recently, an expandable cage equipped with rectangular footplates has been used for anterior vertebral replacement in osteoporotic vertebral fracture (OVF). However, the postoperative changes in global alignment have not been elucidated. The purpose of this study was to evaluate local and global spinal alignment after anterior and posterior spinal fixation (APSF) using an expandable cage in elderly OVF patients. This retrospective multicenter review assessed 54 consecutive patients who underwent APSF for OVF. Clinical outcomes were compared between postoperative sagittal vertical axis (SVA) > 95 mm and ≤95 mm groups to investigate the impact of malalignment. SVA improved by only 18.7 mm (from 111.8 mm to 93.1 mm). VAS score of back pain at final follow-up was significantly higher in patients with SVA > 95 mm than SVA ≤ 95 mm (42.4 vs. 22.6, p = 0.007). Adjacent vertebral fracture after surgery was significantly more frequent in the SVA > 95 mm (37% vs. 11%, p = 0.038). Multiple logistic regression showed significantly increased OR for developing adjacent vertebral fracture (OR = 4.76, 95% CI 1.10–20.58). APSF using the newly developed cage improves local kyphotic angle but not SVA. The main cause for the spinal malalignment after surgery was postoperative development of adjacent vertebral fractures. |
format | Online Article Text |
id | pubmed-8432512 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84325122021-09-11 Direct Lateral Corpectomy and Reconstruction Using an Expandable Cage Improves Local Kyphosis but Not Global Sagittal Alignment Terai, Hidetomi Takahashi, Shinji Yasuda, Hiroyuki Konishi, Sadahiko Maeno, Takafumi Kono, Hiroshi Matsumura, Akira Namikawa, Takashi Kato, Minori Hoshino, Masatoshi Tamai, Koji Toyoda, Hiromitsu Suzuki, Akinobu Nakamura, Hiroaki J Clin Med Article Recently, an expandable cage equipped with rectangular footplates has been used for anterior vertebral replacement in osteoporotic vertebral fracture (OVF). However, the postoperative changes in global alignment have not been elucidated. The purpose of this study was to evaluate local and global spinal alignment after anterior and posterior spinal fixation (APSF) using an expandable cage in elderly OVF patients. This retrospective multicenter review assessed 54 consecutive patients who underwent APSF for OVF. Clinical outcomes were compared between postoperative sagittal vertical axis (SVA) > 95 mm and ≤95 mm groups to investigate the impact of malalignment. SVA improved by only 18.7 mm (from 111.8 mm to 93.1 mm). VAS score of back pain at final follow-up was significantly higher in patients with SVA > 95 mm than SVA ≤ 95 mm (42.4 vs. 22.6, p = 0.007). Adjacent vertebral fracture after surgery was significantly more frequent in the SVA > 95 mm (37% vs. 11%, p = 0.038). Multiple logistic regression showed significantly increased OR for developing adjacent vertebral fracture (OR = 4.76, 95% CI 1.10–20.58). APSF using the newly developed cage improves local kyphotic angle but not SVA. The main cause for the spinal malalignment after surgery was postoperative development of adjacent vertebral fractures. MDPI 2021-09-05 /pmc/articles/PMC8432512/ /pubmed/34501460 http://dx.doi.org/10.3390/jcm10174012 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Terai, Hidetomi Takahashi, Shinji Yasuda, Hiroyuki Konishi, Sadahiko Maeno, Takafumi Kono, Hiroshi Matsumura, Akira Namikawa, Takashi Kato, Minori Hoshino, Masatoshi Tamai, Koji Toyoda, Hiromitsu Suzuki, Akinobu Nakamura, Hiroaki Direct Lateral Corpectomy and Reconstruction Using an Expandable Cage Improves Local Kyphosis but Not Global Sagittal Alignment |
title | Direct Lateral Corpectomy and Reconstruction Using an Expandable Cage Improves Local Kyphosis but Not Global Sagittal Alignment |
title_full | Direct Lateral Corpectomy and Reconstruction Using an Expandable Cage Improves Local Kyphosis but Not Global Sagittal Alignment |
title_fullStr | Direct Lateral Corpectomy and Reconstruction Using an Expandable Cage Improves Local Kyphosis but Not Global Sagittal Alignment |
title_full_unstemmed | Direct Lateral Corpectomy and Reconstruction Using an Expandable Cage Improves Local Kyphosis but Not Global Sagittal Alignment |
title_short | Direct Lateral Corpectomy and Reconstruction Using an Expandable Cage Improves Local Kyphosis but Not Global Sagittal Alignment |
title_sort | direct lateral corpectomy and reconstruction using an expandable cage improves local kyphosis but not global sagittal alignment |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8432512/ https://www.ncbi.nlm.nih.gov/pubmed/34501460 http://dx.doi.org/10.3390/jcm10174012 |
work_keys_str_mv | AT teraihidetomi directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT takahashishinji directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT yasudahiroyuki directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT konishisadahiko directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT maenotakafumi directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT konohiroshi directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT matsumuraakira directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT namikawatakashi directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT katominori directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT hoshinomasatoshi directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT tamaikoji directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT toyodahiromitsu directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT suzukiakinobu directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment AT nakamurahiroaki directlateralcorpectomyandreconstructionusinganexpandablecageimproveslocalkyphosisbutnotglobalsagittalalignment |