Cargando…
Electroless Plating of High-Performance Composite Pd Membranes with EDTA-Free Bath
High-performance composite Pd membranes were successfully fabricated using electroless plating with an EDTA-free bath. The plating started with employing the one-time addition of hydrazine. In the experiment, the hydrazine concentrations and plating bath volumes were systematically varied to optimiz...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8432675/ https://www.ncbi.nlm.nih.gov/pubmed/34500984 http://dx.doi.org/10.3390/ma14174894 |
_version_ | 1783751213935755264 |
---|---|
author | Wang, Jun-Yi Chi, Yen-Hsun Huang, Jin-Hua |
author_facet | Wang, Jun-Yi Chi, Yen-Hsun Huang, Jin-Hua |
author_sort | Wang, Jun-Yi |
collection | PubMed |
description | High-performance composite Pd membranes were successfully fabricated using electroless plating with an EDTA-free bath. The plating started with employing the one-time addition of hydrazine. In the experiment, the hydrazine concentrations and plating bath volumes were systematically varied to optimize the plating. The optimum composite Pd membrane tube showed high H(2) permeance of 4.4 × 10(−3) mol/m(2) s Pa(0.5) and high selectivity of 1.6 × 10(4), but poor cycling stability. Then, a method of sequential addition of the hydrazine from the high to low concentrations was employed. The resultant membrane, about 6 μm thick, still exhibited a high selectivity of 6.8 × 10(4) as well as a much-improved plating yield and cycling stability level; this membrane outperformed the membrane made using the unmodified plating technique with the EDTA-contained bath. This result indicates the EDTA-free bath combined with the sequential addition of hydrazine is a simple, low-cost, yet effective method for preparing thin, dense composite Pd membranes featuring high hydrogen permeation flux and high thermal durability. |
format | Online Article Text |
id | pubmed-8432675 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84326752021-09-11 Electroless Plating of High-Performance Composite Pd Membranes with EDTA-Free Bath Wang, Jun-Yi Chi, Yen-Hsun Huang, Jin-Hua Materials (Basel) Article High-performance composite Pd membranes were successfully fabricated using electroless plating with an EDTA-free bath. The plating started with employing the one-time addition of hydrazine. In the experiment, the hydrazine concentrations and plating bath volumes were systematically varied to optimize the plating. The optimum composite Pd membrane tube showed high H(2) permeance of 4.4 × 10(−3) mol/m(2) s Pa(0.5) and high selectivity of 1.6 × 10(4), but poor cycling stability. Then, a method of sequential addition of the hydrazine from the high to low concentrations was employed. The resultant membrane, about 6 μm thick, still exhibited a high selectivity of 6.8 × 10(4) as well as a much-improved plating yield and cycling stability level; this membrane outperformed the membrane made using the unmodified plating technique with the EDTA-contained bath. This result indicates the EDTA-free bath combined with the sequential addition of hydrazine is a simple, low-cost, yet effective method for preparing thin, dense composite Pd membranes featuring high hydrogen permeation flux and high thermal durability. MDPI 2021-08-27 /pmc/articles/PMC8432675/ /pubmed/34500984 http://dx.doi.org/10.3390/ma14174894 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Jun-Yi Chi, Yen-Hsun Huang, Jin-Hua Electroless Plating of High-Performance Composite Pd Membranes with EDTA-Free Bath |
title | Electroless Plating of High-Performance Composite Pd Membranes with EDTA-Free Bath |
title_full | Electroless Plating of High-Performance Composite Pd Membranes with EDTA-Free Bath |
title_fullStr | Electroless Plating of High-Performance Composite Pd Membranes with EDTA-Free Bath |
title_full_unstemmed | Electroless Plating of High-Performance Composite Pd Membranes with EDTA-Free Bath |
title_short | Electroless Plating of High-Performance Composite Pd Membranes with EDTA-Free Bath |
title_sort | electroless plating of high-performance composite pd membranes with edta-free bath |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8432675/ https://www.ncbi.nlm.nih.gov/pubmed/34500984 http://dx.doi.org/10.3390/ma14174894 |
work_keys_str_mv | AT wangjunyi electrolessplatingofhighperformancecompositepdmembraneswithedtafreebath AT chiyenhsun electrolessplatingofhighperformancecompositepdmembraneswithedtafreebath AT huangjinhua electrolessplatingofhighperformancecompositepdmembraneswithedtafreebath |