Cargando…

Compatibility Optimal Design of Axially Loaded Circular Concrete-Filled Steel Tube Stub Columns

Numerous studies have been carried out on the axially loaded circular concrete-filled steel tube (CCFST) stub columns. However, to date, no clear evaluation criterion for the compatibility of its design parameters has been established. In the present study, the compatibility of the design parameters...

Descripción completa

Detalles Bibliográficos
Autores principales: Fan, Jinglin, Lyu, Fei, Ding, Faxing, Bu, Dan, Wang, Siqing, Tan, Zhongkun, Tan, Sui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8432730/
https://www.ncbi.nlm.nih.gov/pubmed/34500929
http://dx.doi.org/10.3390/ma14174839
_version_ 1783751226605699072
author Fan, Jinglin
Lyu, Fei
Ding, Faxing
Bu, Dan
Wang, Siqing
Tan, Zhongkun
Tan, Sui
author_facet Fan, Jinglin
Lyu, Fei
Ding, Faxing
Bu, Dan
Wang, Siqing
Tan, Zhongkun
Tan, Sui
author_sort Fan, Jinglin
collection PubMed
description Numerous studies have been carried out on the axially loaded circular concrete-filled steel tube (CCFST) stub columns. However, to date, no clear evaluation criterion for the compatibility of its design parameters has been established. In the present study, the compatibility of the design parameters (concrete compressive strength [Formula: see text] , steel yield strength [Formula: see text] , diameter D and thickness of steel tube t) of axially loaded CCFST stub columns was quantitatively investigated in terms of the contribution of the composite actions to the axial bearing capacity of the columns. The composite ratio [Formula: see text] was proposed as an indicator to represent the effectiveness of the composite actions. A numerical framework of the determination of [Formula: see text] was established, making use of a series of existing widely recognized constitutive models of structural steel and concrete. Some modifications were carried out on these models to ensure the numerical stability of the presented analysis. Moreover, the rationality of the combined use of these models was verified. The analytical results show that excessive or very small [Formula: see text] ratio should be avoided in design. Meanwhile, the combined use of low-strength steel and high-strength concrete should be avoided. A table of optimal [Formula: see text] ratios corresponding to different material strength matches was provided for designers. Finally, an optimization of the design parameters using the proposed method and the existing design specification was performed.
format Online
Article
Text
id pubmed-8432730
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84327302021-09-11 Compatibility Optimal Design of Axially Loaded Circular Concrete-Filled Steel Tube Stub Columns Fan, Jinglin Lyu, Fei Ding, Faxing Bu, Dan Wang, Siqing Tan, Zhongkun Tan, Sui Materials (Basel) Article Numerous studies have been carried out on the axially loaded circular concrete-filled steel tube (CCFST) stub columns. However, to date, no clear evaluation criterion for the compatibility of its design parameters has been established. In the present study, the compatibility of the design parameters (concrete compressive strength [Formula: see text] , steel yield strength [Formula: see text] , diameter D and thickness of steel tube t) of axially loaded CCFST stub columns was quantitatively investigated in terms of the contribution of the composite actions to the axial bearing capacity of the columns. The composite ratio [Formula: see text] was proposed as an indicator to represent the effectiveness of the composite actions. A numerical framework of the determination of [Formula: see text] was established, making use of a series of existing widely recognized constitutive models of structural steel and concrete. Some modifications were carried out on these models to ensure the numerical stability of the presented analysis. Moreover, the rationality of the combined use of these models was verified. The analytical results show that excessive or very small [Formula: see text] ratio should be avoided in design. Meanwhile, the combined use of low-strength steel and high-strength concrete should be avoided. A table of optimal [Formula: see text] ratios corresponding to different material strength matches was provided for designers. Finally, an optimization of the design parameters using the proposed method and the existing design specification was performed. MDPI 2021-08-26 /pmc/articles/PMC8432730/ /pubmed/34500929 http://dx.doi.org/10.3390/ma14174839 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fan, Jinglin
Lyu, Fei
Ding, Faxing
Bu, Dan
Wang, Siqing
Tan, Zhongkun
Tan, Sui
Compatibility Optimal Design of Axially Loaded Circular Concrete-Filled Steel Tube Stub Columns
title Compatibility Optimal Design of Axially Loaded Circular Concrete-Filled Steel Tube Stub Columns
title_full Compatibility Optimal Design of Axially Loaded Circular Concrete-Filled Steel Tube Stub Columns
title_fullStr Compatibility Optimal Design of Axially Loaded Circular Concrete-Filled Steel Tube Stub Columns
title_full_unstemmed Compatibility Optimal Design of Axially Loaded Circular Concrete-Filled Steel Tube Stub Columns
title_short Compatibility Optimal Design of Axially Loaded Circular Concrete-Filled Steel Tube Stub Columns
title_sort compatibility optimal design of axially loaded circular concrete-filled steel tube stub columns
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8432730/
https://www.ncbi.nlm.nih.gov/pubmed/34500929
http://dx.doi.org/10.3390/ma14174839
work_keys_str_mv AT fanjinglin compatibilityoptimaldesignofaxiallyloadedcircularconcretefilledsteeltubestubcolumns
AT lyufei compatibilityoptimaldesignofaxiallyloadedcircularconcretefilledsteeltubestubcolumns
AT dingfaxing compatibilityoptimaldesignofaxiallyloadedcircularconcretefilledsteeltubestubcolumns
AT budan compatibilityoptimaldesignofaxiallyloadedcircularconcretefilledsteeltubestubcolumns
AT wangsiqing compatibilityoptimaldesignofaxiallyloadedcircularconcretefilledsteeltubestubcolumns
AT tanzhongkun compatibilityoptimaldesignofaxiallyloadedcircularconcretefilledsteeltubestubcolumns
AT tansui compatibilityoptimaldesignofaxiallyloadedcircularconcretefilledsteeltubestubcolumns