The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty

BACKGROUND: Preservation of joint line height is an important factor in post-operative function after Total Knee Arthroplasty (TKA). This is the first study investigating the reliability of the novel Imperial Joint Line Congruency Measurement (IJLCM) technique for the assessment of joint line height...

Descripción completa

Detalles Bibliográficos
Autores principales: Popat, Ravi, Dhillon, Kieran, Mahapatra, Piyush, Khan, Hasaan, Nathwani, Dinesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8432761/
https://www.ncbi.nlm.nih.gov/pubmed/34506586
http://dx.doi.org/10.1371/journal.pone.0257325
_version_ 1783751231364136960
author Popat, Ravi
Dhillon, Kieran
Mahapatra, Piyush
Khan, Hasaan
Nathwani, Dinesh
author_facet Popat, Ravi
Dhillon, Kieran
Mahapatra, Piyush
Khan, Hasaan
Nathwani, Dinesh
author_sort Popat, Ravi
collection PubMed
description BACKGROUND: Preservation of joint line height is an important factor in post-operative function after Total Knee Arthroplasty (TKA). This is the first study investigating the reliability of the novel Imperial Joint Line Congruency Measurement (IJLCM) technique for the assessment of joint line height using plain radiographs. METHODS: The reliability of two techniques used to measure joint line height on pre-operative and post-operative plain radiographs is presented. 120 patients that underwent TKA from 6 different international centres were included. Measurements were performed using each technique by two senior orthopaedic surgeons at two different timepoints (test-retest). Two undergraduate medical students performed joint line measurements using the most reproducible of the two techniques on 40 pre-operative and post-operative images to establish the reliability of the measurement technique. RESULTS: The IJLCM demonstrated an average absolute difference of 1.83mm (CI 1.56–2.10mm) and excellent inter and intra-rater reliability between senior orthopaedic surgeons (>0.92 (CI 0.88–0.94) when measuring joint line height on plain radiographs. Overall Crohnbach’s alpha over 0.92 confirmed internal consistency. Measurements performed using the control technique as previously described by Figgie et al. had an average absolute difference of 5.75mm (5.17–6.32mm). Comparison of measurements by senior orthopaedic surgeons and medical students using the IJLCM technique with ANOVA and student’s t-test demonstrated acceptable agreement and inter-rater reliability of >0.92 (0.87–0.95). CONCLUSION: This study shows excellent accuracy, precision, and reliability of the novel IJLCM technique. Furthermore, excellent agreement between senior orthopaedic surgeons and medical students when using the IJLCM could be shown. The IJLCM technique is reliable for joint line assessment.
format Online
Article
Text
id pubmed-8432761
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-84327612021-09-11 The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty Popat, Ravi Dhillon, Kieran Mahapatra, Piyush Khan, Hasaan Nathwani, Dinesh PLoS One Research Article BACKGROUND: Preservation of joint line height is an important factor in post-operative function after Total Knee Arthroplasty (TKA). This is the first study investigating the reliability of the novel Imperial Joint Line Congruency Measurement (IJLCM) technique for the assessment of joint line height using plain radiographs. METHODS: The reliability of two techniques used to measure joint line height on pre-operative and post-operative plain radiographs is presented. 120 patients that underwent TKA from 6 different international centres were included. Measurements were performed using each technique by two senior orthopaedic surgeons at two different timepoints (test-retest). Two undergraduate medical students performed joint line measurements using the most reproducible of the two techniques on 40 pre-operative and post-operative images to establish the reliability of the measurement technique. RESULTS: The IJLCM demonstrated an average absolute difference of 1.83mm (CI 1.56–2.10mm) and excellent inter and intra-rater reliability between senior orthopaedic surgeons (>0.92 (CI 0.88–0.94) when measuring joint line height on plain radiographs. Overall Crohnbach’s alpha over 0.92 confirmed internal consistency. Measurements performed using the control technique as previously described by Figgie et al. had an average absolute difference of 5.75mm (5.17–6.32mm). Comparison of measurements by senior orthopaedic surgeons and medical students using the IJLCM technique with ANOVA and student’s t-test demonstrated acceptable agreement and inter-rater reliability of >0.92 (0.87–0.95). CONCLUSION: This study shows excellent accuracy, precision, and reliability of the novel IJLCM technique. Furthermore, excellent agreement between senior orthopaedic surgeons and medical students when using the IJLCM could be shown. The IJLCM technique is reliable for joint line assessment. Public Library of Science 2021-09-10 /pmc/articles/PMC8432761/ /pubmed/34506586 http://dx.doi.org/10.1371/journal.pone.0257325 Text en © 2021 Popat et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Popat, Ravi
Dhillon, Kieran
Mahapatra, Piyush
Khan, Hasaan
Nathwani, Dinesh
The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty
title The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty
title_full The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty
title_fullStr The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty
title_full_unstemmed The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty
title_short The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty
title_sort imperial joint line congruency measurement is a valuable tool in total knee arthroplasty
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8432761/
https://www.ncbi.nlm.nih.gov/pubmed/34506586
http://dx.doi.org/10.1371/journal.pone.0257325
work_keys_str_mv AT popatravi theimperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty
AT dhillonkieran theimperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty
AT mahapatrapiyush theimperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty
AT khanhasaan theimperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty
AT nathwanidinesh theimperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty
AT popatravi imperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty
AT dhillonkieran imperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty
AT mahapatrapiyush imperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty
AT khanhasaan imperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty
AT nathwanidinesh imperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty