Cargando…
The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty
BACKGROUND: Preservation of joint line height is an important factor in post-operative function after Total Knee Arthroplasty (TKA). This is the first study investigating the reliability of the novel Imperial Joint Line Congruency Measurement (IJLCM) technique for the assessment of joint line height...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8432761/ https://www.ncbi.nlm.nih.gov/pubmed/34506586 http://dx.doi.org/10.1371/journal.pone.0257325 |
_version_ | 1783751231364136960 |
---|---|
author | Popat, Ravi Dhillon, Kieran Mahapatra, Piyush Khan, Hasaan Nathwani, Dinesh |
author_facet | Popat, Ravi Dhillon, Kieran Mahapatra, Piyush Khan, Hasaan Nathwani, Dinesh |
author_sort | Popat, Ravi |
collection | PubMed |
description | BACKGROUND: Preservation of joint line height is an important factor in post-operative function after Total Knee Arthroplasty (TKA). This is the first study investigating the reliability of the novel Imperial Joint Line Congruency Measurement (IJLCM) technique for the assessment of joint line height using plain radiographs. METHODS: The reliability of two techniques used to measure joint line height on pre-operative and post-operative plain radiographs is presented. 120 patients that underwent TKA from 6 different international centres were included. Measurements were performed using each technique by two senior orthopaedic surgeons at two different timepoints (test-retest). Two undergraduate medical students performed joint line measurements using the most reproducible of the two techniques on 40 pre-operative and post-operative images to establish the reliability of the measurement technique. RESULTS: The IJLCM demonstrated an average absolute difference of 1.83mm (CI 1.56–2.10mm) and excellent inter and intra-rater reliability between senior orthopaedic surgeons (>0.92 (CI 0.88–0.94) when measuring joint line height on plain radiographs. Overall Crohnbach’s alpha over 0.92 confirmed internal consistency. Measurements performed using the control technique as previously described by Figgie et al. had an average absolute difference of 5.75mm (5.17–6.32mm). Comparison of measurements by senior orthopaedic surgeons and medical students using the IJLCM technique with ANOVA and student’s t-test demonstrated acceptable agreement and inter-rater reliability of >0.92 (0.87–0.95). CONCLUSION: This study shows excellent accuracy, precision, and reliability of the novel IJLCM technique. Furthermore, excellent agreement between senior orthopaedic surgeons and medical students when using the IJLCM could be shown. The IJLCM technique is reliable for joint line assessment. |
format | Online Article Text |
id | pubmed-8432761 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-84327612021-09-11 The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty Popat, Ravi Dhillon, Kieran Mahapatra, Piyush Khan, Hasaan Nathwani, Dinesh PLoS One Research Article BACKGROUND: Preservation of joint line height is an important factor in post-operative function after Total Knee Arthroplasty (TKA). This is the first study investigating the reliability of the novel Imperial Joint Line Congruency Measurement (IJLCM) technique for the assessment of joint line height using plain radiographs. METHODS: The reliability of two techniques used to measure joint line height on pre-operative and post-operative plain radiographs is presented. 120 patients that underwent TKA from 6 different international centres were included. Measurements were performed using each technique by two senior orthopaedic surgeons at two different timepoints (test-retest). Two undergraduate medical students performed joint line measurements using the most reproducible of the two techniques on 40 pre-operative and post-operative images to establish the reliability of the measurement technique. RESULTS: The IJLCM demonstrated an average absolute difference of 1.83mm (CI 1.56–2.10mm) and excellent inter and intra-rater reliability between senior orthopaedic surgeons (>0.92 (CI 0.88–0.94) when measuring joint line height on plain radiographs. Overall Crohnbach’s alpha over 0.92 confirmed internal consistency. Measurements performed using the control technique as previously described by Figgie et al. had an average absolute difference of 5.75mm (5.17–6.32mm). Comparison of measurements by senior orthopaedic surgeons and medical students using the IJLCM technique with ANOVA and student’s t-test demonstrated acceptable agreement and inter-rater reliability of >0.92 (0.87–0.95). CONCLUSION: This study shows excellent accuracy, precision, and reliability of the novel IJLCM technique. Furthermore, excellent agreement between senior orthopaedic surgeons and medical students when using the IJLCM could be shown. The IJLCM technique is reliable for joint line assessment. Public Library of Science 2021-09-10 /pmc/articles/PMC8432761/ /pubmed/34506586 http://dx.doi.org/10.1371/journal.pone.0257325 Text en © 2021 Popat et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Popat, Ravi Dhillon, Kieran Mahapatra, Piyush Khan, Hasaan Nathwani, Dinesh The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty |
title | The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty |
title_full | The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty |
title_fullStr | The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty |
title_full_unstemmed | The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty |
title_short | The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty |
title_sort | imperial joint line congruency measurement is a valuable tool in total knee arthroplasty |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8432761/ https://www.ncbi.nlm.nih.gov/pubmed/34506586 http://dx.doi.org/10.1371/journal.pone.0257325 |
work_keys_str_mv | AT popatravi theimperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty AT dhillonkieran theimperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty AT mahapatrapiyush theimperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty AT khanhasaan theimperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty AT nathwanidinesh theimperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty AT popatravi imperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty AT dhillonkieran imperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty AT mahapatrapiyush imperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty AT khanhasaan imperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty AT nathwanidinesh imperialjointlinecongruencymeasurementisavaluabletoolintotalkneearthroplasty |