Cargando…

A reusable PMMA/paper hybrid plug-and-play microfluidic device for an ultrasensitive immunoassay with a wide dynamic range

Conventional colorimetric enzyme-linked immunosorbent assay (ELISA) is a time-consuming laboratory assay that is not very sensitive and consumes a large amount of samples. Herein, the development of a reusable, cost-effective, and eco-friendly poly(methyl methacrylate) (PMMA)/paper hybrid plug-and-p...

Descripción completa

Detalles Bibliográficos
Autores principales: Sanjay, Sharma T., Li, Meihan, Zhou, Wan, Li, Xiaochun, Li, XiuJun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8433292/
https://www.ncbi.nlm.nih.gov/pubmed/34567643
http://dx.doi.org/10.1038/s41378-020-0143-5
_version_ 1783751345827741696
author Sanjay, Sharma T.
Li, Meihan
Zhou, Wan
Li, Xiaochun
Li, XiuJun
author_facet Sanjay, Sharma T.
Li, Meihan
Zhou, Wan
Li, Xiaochun
Li, XiuJun
author_sort Sanjay, Sharma T.
collection PubMed
description Conventional colorimetric enzyme-linked immunosorbent assay (ELISA) is a time-consuming laboratory assay that is not very sensitive and consumes a large amount of samples. Herein, the development of a reusable, cost-effective, and eco-friendly poly(methyl methacrylate) (PMMA)/paper hybrid plug-and-play (PnP) device for high-sensitivity immunoassay by analyte enrichment and efficient passing-through washing has been reported. The PMMA device has multiple slots where a pre-patterned paper substrate can be inserted. The sample flows back-and-forth through a low-cost, 3D paper substrate within the PMMA channels, thereby enhancing the amount of analyte adsorbed and dramatically increasing the sensitivity while decreasing the assay time. After the enrichment assay, the paper substrate can simply be pulled out of the device, and the results can be qualitatively viewed with the naked eye or scanned through a simple desktop scanner for quantitative analysis. The paper substrate can be replaced with a new substrate so that the device can be reused. The limits of detection (LODs) of 200 pg/mL for immunoglobulin G (IgG) and 270 pg/mL for hepatitis B surface antigen (HBsAg) were obtained. This IgG assay is at least 10 times more sensitive than commercial ELISA kits. In addition, the PnP ELISA exhibited a significant increase in the linear dynamic range from 3 orders of magnitude in a common paper-based device to a wide range of six orders of magnitude in the PnP hybrid device. This reusable PnP device has great potential for the low-cost yet high-sensitivity detection of infectious diseases, cancers, and other important biomolecules.
format Online
Article
Text
id pubmed-8433292
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-84332922021-09-24 A reusable PMMA/paper hybrid plug-and-play microfluidic device for an ultrasensitive immunoassay with a wide dynamic range Sanjay, Sharma T. Li, Meihan Zhou, Wan Li, Xiaochun Li, XiuJun Microsyst Nanoeng Article Conventional colorimetric enzyme-linked immunosorbent assay (ELISA) is a time-consuming laboratory assay that is not very sensitive and consumes a large amount of samples. Herein, the development of a reusable, cost-effective, and eco-friendly poly(methyl methacrylate) (PMMA)/paper hybrid plug-and-play (PnP) device for high-sensitivity immunoassay by analyte enrichment and efficient passing-through washing has been reported. The PMMA device has multiple slots where a pre-patterned paper substrate can be inserted. The sample flows back-and-forth through a low-cost, 3D paper substrate within the PMMA channels, thereby enhancing the amount of analyte adsorbed and dramatically increasing the sensitivity while decreasing the assay time. After the enrichment assay, the paper substrate can simply be pulled out of the device, and the results can be qualitatively viewed with the naked eye or scanned through a simple desktop scanner for quantitative analysis. The paper substrate can be replaced with a new substrate so that the device can be reused. The limits of detection (LODs) of 200 pg/mL for immunoglobulin G (IgG) and 270 pg/mL for hepatitis B surface antigen (HBsAg) were obtained. This IgG assay is at least 10 times more sensitive than commercial ELISA kits. In addition, the PnP ELISA exhibited a significant increase in the linear dynamic range from 3 orders of magnitude in a common paper-based device to a wide range of six orders of magnitude in the PnP hybrid device. This reusable PnP device has great potential for the low-cost yet high-sensitivity detection of infectious diseases, cancers, and other important biomolecules. Nature Publishing Group UK 2020-06-15 /pmc/articles/PMC8433292/ /pubmed/34567643 http://dx.doi.org/10.1038/s41378-020-0143-5 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Sanjay, Sharma T.
Li, Meihan
Zhou, Wan
Li, Xiaochun
Li, XiuJun
A reusable PMMA/paper hybrid plug-and-play microfluidic device for an ultrasensitive immunoassay with a wide dynamic range
title A reusable PMMA/paper hybrid plug-and-play microfluidic device for an ultrasensitive immunoassay with a wide dynamic range
title_full A reusable PMMA/paper hybrid plug-and-play microfluidic device for an ultrasensitive immunoassay with a wide dynamic range
title_fullStr A reusable PMMA/paper hybrid plug-and-play microfluidic device for an ultrasensitive immunoassay with a wide dynamic range
title_full_unstemmed A reusable PMMA/paper hybrid plug-and-play microfluidic device for an ultrasensitive immunoassay with a wide dynamic range
title_short A reusable PMMA/paper hybrid plug-and-play microfluidic device for an ultrasensitive immunoassay with a wide dynamic range
title_sort reusable pmma/paper hybrid plug-and-play microfluidic device for an ultrasensitive immunoassay with a wide dynamic range
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8433292/
https://www.ncbi.nlm.nih.gov/pubmed/34567643
http://dx.doi.org/10.1038/s41378-020-0143-5
work_keys_str_mv AT sanjaysharmat areusablepmmapaperhybridplugandplaymicrofluidicdeviceforanultrasensitiveimmunoassaywithawidedynamicrange
AT limeihan areusablepmmapaperhybridplugandplaymicrofluidicdeviceforanultrasensitiveimmunoassaywithawidedynamicrange
AT zhouwan areusablepmmapaperhybridplugandplaymicrofluidicdeviceforanultrasensitiveimmunoassaywithawidedynamicrange
AT lixiaochun areusablepmmapaperhybridplugandplaymicrofluidicdeviceforanultrasensitiveimmunoassaywithawidedynamicrange
AT lixiujun areusablepmmapaperhybridplugandplaymicrofluidicdeviceforanultrasensitiveimmunoassaywithawidedynamicrange
AT sanjaysharmat reusablepmmapaperhybridplugandplaymicrofluidicdeviceforanultrasensitiveimmunoassaywithawidedynamicrange
AT limeihan reusablepmmapaperhybridplugandplaymicrofluidicdeviceforanultrasensitiveimmunoassaywithawidedynamicrange
AT zhouwan reusablepmmapaperhybridplugandplaymicrofluidicdeviceforanultrasensitiveimmunoassaywithawidedynamicrange
AT lixiaochun reusablepmmapaperhybridplugandplaymicrofluidicdeviceforanultrasensitiveimmunoassaywithawidedynamicrange
AT lixiujun reusablepmmapaperhybridplugandplaymicrofluidicdeviceforanultrasensitiveimmunoassaywithawidedynamicrange