Cargando…
Thermally-actuated microfluidic membrane valve for point-of-care applications
Microfluidics has enabled low volume biochemistry reactions to be carried out at the point-of-care. A key component in microfluidics is the microfluidic valve. Microfluidic valves are not only useful for directing flow at intersections but also allow mixtures/dilutions to be tuned real-time and even...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8433387/ https://www.ncbi.nlm.nih.gov/pubmed/34567761 http://dx.doi.org/10.1038/s41378-021-00260-3 |
_version_ | 1783751367003734016 |
---|---|
author | Sesen, Muhsincan Rowlands, Christopher J. |
author_facet | Sesen, Muhsincan Rowlands, Christopher J. |
author_sort | Sesen, Muhsincan |
collection | PubMed |
description | Microfluidics has enabled low volume biochemistry reactions to be carried out at the point-of-care. A key component in microfluidics is the microfluidic valve. Microfluidic valves are not only useful for directing flow at intersections but also allow mixtures/dilutions to be tuned real-time and even provide peristaltic pumping capabilities. In the transition from chip-in-a-lab to lab-on-a-chip, it is essential to ensure that microfluidic valves are designed to require less peripheral equipment and that they are transportable. In this paper, a thermally-actuated microfluidic valve is presented. The valve itself is fabricated with off-the-shelf components without the need for sophisticated cleanroom techniques. It is shown that multiple valves can be controlled and operated via a power supply and an Arduino microcontroller; an important step towards transportable microfluidic devices capable of carrying out analytical assays at the point-of-care. It is been calculated that a single actuator costs less than $1, this highlights the potential of the presented valve for scaling out. The valve operation is demonstrated by adjusting the ratio of a water/dye mixture in a continuous flow microfluidic chip with Y-junction channel geometry. The power required to operate one microfluidic valve has been characterised both theoretically and experimentally. Cyclical operation of the valve has been demonstrated for 65 h with 585 actuations. The presented valve is capable of actuating rectangular microfluidic channels of 500 μm × 50 μm with an expected temperature increase of up to 5 °C. The fastest actuation times achieved were 2 s for valve closing (heating) and 9 s for valve opening (cooling). |
format | Online Article Text |
id | pubmed-8433387 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-84333872021-09-24 Thermally-actuated microfluidic membrane valve for point-of-care applications Sesen, Muhsincan Rowlands, Christopher J. Microsyst Nanoeng Article Microfluidics has enabled low volume biochemistry reactions to be carried out at the point-of-care. A key component in microfluidics is the microfluidic valve. Microfluidic valves are not only useful for directing flow at intersections but also allow mixtures/dilutions to be tuned real-time and even provide peristaltic pumping capabilities. In the transition from chip-in-a-lab to lab-on-a-chip, it is essential to ensure that microfluidic valves are designed to require less peripheral equipment and that they are transportable. In this paper, a thermally-actuated microfluidic valve is presented. The valve itself is fabricated with off-the-shelf components without the need for sophisticated cleanroom techniques. It is shown that multiple valves can be controlled and operated via a power supply and an Arduino microcontroller; an important step towards transportable microfluidic devices capable of carrying out analytical assays at the point-of-care. It is been calculated that a single actuator costs less than $1, this highlights the potential of the presented valve for scaling out. The valve operation is demonstrated by adjusting the ratio of a water/dye mixture in a continuous flow microfluidic chip with Y-junction channel geometry. The power required to operate one microfluidic valve has been characterised both theoretically and experimentally. Cyclical operation of the valve has been demonstrated for 65 h with 585 actuations. The presented valve is capable of actuating rectangular microfluidic channels of 500 μm × 50 μm with an expected temperature increase of up to 5 °C. The fastest actuation times achieved were 2 s for valve closing (heating) and 9 s for valve opening (cooling). Nature Publishing Group UK 2021-06-15 /pmc/articles/PMC8433387/ /pubmed/34567761 http://dx.doi.org/10.1038/s41378-021-00260-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Sesen, Muhsincan Rowlands, Christopher J. Thermally-actuated microfluidic membrane valve for point-of-care applications |
title | Thermally-actuated microfluidic membrane valve for point-of-care applications |
title_full | Thermally-actuated microfluidic membrane valve for point-of-care applications |
title_fullStr | Thermally-actuated microfluidic membrane valve for point-of-care applications |
title_full_unstemmed | Thermally-actuated microfluidic membrane valve for point-of-care applications |
title_short | Thermally-actuated microfluidic membrane valve for point-of-care applications |
title_sort | thermally-actuated microfluidic membrane valve for point-of-care applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8433387/ https://www.ncbi.nlm.nih.gov/pubmed/34567761 http://dx.doi.org/10.1038/s41378-021-00260-3 |
work_keys_str_mv | AT sesenmuhsincan thermallyactuatedmicrofluidicmembranevalveforpointofcareapplications AT rowlandschristopherj thermallyactuatedmicrofluidicmembranevalveforpointofcareapplications |